An experimental result on flaw sizing of steam generator tube at nuclear power plants using ultrasonic testing

被引:7
作者
Yoon, Byungsik [1 ]
Kim, Yongsik [1 ]
Yang, Seunghan [1 ]
机构
[1] KHNP Cent Res Inst, NDE Technol Grp, Taejon 305343, South Korea
关键词
nuclear power plant; steam generator; ultrasonic testing; eddy current testing; flaw sizing; in-service inspection;
D O I
10.1080/00223131.2012.693888
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A steam generator at a nuclear power plant consists of thousands of thin tubes, and is a highly important component in operation. Also, steam generator tubes play a critical role in maintaining pressure boundaries of the primary and secondary sides, and can be easily damaged due to operation conditions caused by high temperature and pressure. Therefore, considerable amount of efforts are being committed to evaluating structural integrity of steam generators during in-service inspection. Eddy current testing is the commonly used inspection technique to evaluate a steam generator tube's integrity, but it has limitations in accurately sizing flaws due to the nature of the technique which determines size based on the entire volume of a flaw. In this study, experiments were performed by using ultrasonic testing instead of eddy current testing for the inspection of steam generator tubes to detect various kinds of flaws and to see if the detected flaws can be sized accurately. Consequently, the ultrasonic testing technique could detect various types of flaw, and the flaw sizing results were reliable in length and depth.
引用
收藏
页码:760 / 767
页数:8
相关论文
共 7 条
  • [1] Behravesh M., 2002, TR1003138 EPRI NDE C
  • [2] Choi M.S., 2002, J KOREAN SOC NONDEST, V22, P198
  • [3] Choi M.S., 2001, J KOREAN SOC NONDEST, V21, P501
  • [4] Gay L., 1998, P 7 EUR C NOND TEST, P26
  • [5] Kenefick S., 1999, TE114508 EPRI NDE CT, P1
  • [6] Kenefick S., 2000, 2 INT C NDE REL STRU, P3
  • [7] Kenefick S., 1999, TE114394 EPRI NDE CT