Classification of silica fine particles using a novel electric hydrocyclone

被引:9
作者
Pratarn, W
Wiwut, T
Yoshida, H
机构
[1] Natl Nanotechnol Ctr, Klongluang 12120, Pathumthani, Thailand
[2] Chulalongkorn Univ, Dept Chem Engn, Fac Engn, Bangkok 10330, Thailand
[3] Hiroshima Univ, Dept Chem Engn, Fac Engn, Hiroshima, Japan
关键词
classification; silica; particles; electric; hydrocyclone;
D O I
10.1016/j.stam.2005.02.015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel electric hydrocyclone is developed and tested. Aqueous suspensions of silica with a median diameter of 754 nm and 0.2% volumetric concentration are tested using a 20-mm-diameter hydrocyclone. The ratios of tested underflow rate to throughput are: 0, 0.1, 0.2 and 0.3. The tested volumetric flow rates are 0.083 x 10(-3), 0.117 x 10(-3) and 0.167 x 10(-3) m(3)/s (5, 7 and 10 l/min). The conical part of the electric hydrocyclone, is connected to a cylindrical dust box having 42 mm diameter. This dust box has a central metal rod cone and a cylindrical metal wall between which the desired 50-volt DC electric potential or no potential is applied. The investigated lengths of the dust box are 53 and 106 mm. The three different conditions investigated are: (a) no applied electric potential, (b) positive potential applied at the central rod side and negative potential at the side wall, and (c) positive potential applied at the side wall and negative potential at the central rod side. In both the absence and presence of the underflow, the hydrocyclone with a long dust box is found to give better classification efficiency than that with a short dust box. Interestingly, the effect of electric potential is reversed with respect to the presence and absence of the underflow. The presence of the underflow unexpectedly increase the 50% particle cut size when electric potential is applied. However, the effect of electric potential is reversed when there is no underflow. The electric potential can reduce the 50% particle cut size by up to 10% compared to the absence of electricity. It is found that condition (c) exhibits a stronger effect than condition (b). As expected, the higher the flow ratio, the smaller the particle cut size becomes. Based on the experimental results, an empirical correlation for the 50% particle cut size has been obtained. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 369
页数:6
相关论文
共 32 条
[1]  
[Anonymous], 1958, Chem. Ing. Tech., V30, P85, DOI 10.1002/cite.330300206
[2]  
ANTUNES M, 1992, FLUID MEC A, V12, P3
[3]  
BRADLEY D, 1965, HYDROCYCLONE, P1
[4]  
BRADLEY D, 1959, T I CHEM ENG-LOND, P37
[5]  
BROOKES G, 1984, 2 INT C HYDR BHRA SE
[6]  
Chaston I. R. M., 1958, T I MIN METALL, V67, P203
[7]   The application of mini-hydrocyclones in the concentration of yeast suspensions [J].
Cilliers, JJ ;
Harrison, STL .
CHEMICAL ENGINEERING JOURNAL, 1997, 65 (01) :21-26
[8]  
DAHLSTROM DA, 1949, AIME T, V184, P331
[9]  
DAHLSTROM DA, 1954, CHEM ENG PROGR S SER, V15, P41
[10]  
DEGELDER AL, 1957, SCALING CHEM PLANT P, pS47