The limits of determination for anions in water with the capillary electrophoresis method

被引:0
|
作者
Klojzy-Karczmarczyk, B [1 ]
Kmiecik, E [1 ]
Knap, W [1 ]
机构
[1] Stanislaw Staszic Univ Min & Met, Hydrol & Water Protect Dept, PL-30059 Krakow, Poland
来源
CHEMIA ANALITYCZNA | 2001年 / 46卷 / 03期
关键词
quality control; limits of decision; detection; determination; precision of results; capillary electrophoresis;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the case of capillary electrophoresis the limits of determination xo cannot be defined according to the accepted definition. The paper presents the approach applied and recommended by EURACHEM, relying on the approximation of the graph representing the relationships between the relative standard deviation RSD (%) and the concentration of given indicator in the spiked sample. Consistent with this approach the limit of determination is the lowest concentration of analyte in the sample which can be exactly quantified with precision, determined by the level of RSD (%).
引用
收藏
页码:377 / 385
页数:9
相关论文
共 50 条
  • [1] Determination of anions, cations, and sugars in coconut water by capillary electrophoresis
    Richter, EM
    de Jesus, DP
    Muñoz, RAA
    do Lago, CL
    Angnes, L
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (6A) : 1134 - 1139
  • [2] ANALYSIS OF ANIONS IN RAIN WATER BY CAPILLARY ELECTROPHORESIS
    NGUYEN, HMYL
    TAMISIERKAROLAK, SL
    CZOK, M
    LAUGIER, R
    CARDOT, P
    ANALUSIS, 1995, 23 (02) : 82 - 87
  • [3] Study on simultaneous determination methods for anions by capillary electrophoresis
    Soga, T
    BUNSEKI KAGAKU, 2000, 49 (08) : 645 - 646
  • [4] Simultaneous determination of anions by capillary electrophoresis: Characteristics and applications
    Colombara, R
    Tavares, MFM
    Massaro, S
    QUIMICA NOVA, 1997, 20 (05): : 512 - 518
  • [5] Determination of major inorganic anions in rainwater by capillary electrophoresis
    Deng, YW
    WATER RESEARCH, 1998, 32 (08) : 2249 - 2256
  • [6] Determination of inorganic anions in Kraft pulping liquors by capillary electrophoresis
    Masselter, SM
    Zemann, AJ
    Bonn, GK
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1996, 19 (03): : 131 - 136
  • [7] Determination of inorganic and organic anions in beer and wort by capillary electrophoresis
    Soga, T
    Wakaura, M
    JOURNAL OF THE AMERICAN SOCIETY OF BREWING CHEMISTS, 1997, 55 (02) : 44 - 46
  • [8] Determination of inorganic anions in human saliva by zwitterionic micellar capillary electrophoresis
    Masanobu Mori
    Wenzhi Hu
    James S. Fritz
    Hirohito Tsue
    Takashi Kaneta
    S. Tanaka
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 429 - 433
  • [9] Optimization and Validation of a New Capillary Electrophoresis Method with Conductivity Detection for Determination of Small Anions in Red Wines
    Lelova, Zorica
    Ivanova-Petropulos, Violeta
    Masar, Marian
    Lisjak, Klemen
    Bodor, Robert
    FOOD ANALYTICAL METHODS, 2018, 11 (05) : 1457 - 1466
  • [10] A bi-end injection capillary electrophoresis method for simultaneous determination of 37 cations and anions in beers
    Chao Guo
    Zhenpeng Guo
    Yi Chen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4113 - 4121