Responders to cardiac resynchronization therapy with narrow or intermediate QRS complexes identified by simple echocardiographic indices of dyssynchrony: The DESIRE study

被引:44
作者
Cazeau, Serge J. [1 ]
Daubert, J-Claude [2 ]
Tavazzi, Luigi [3 ]
Frohlig, Gerd [4 ]
Paul, Vince [5 ]
机构
[1] Inparys Clin Res Grp, F-92210 St Cloud, France
[2] Univ Hosp, Rennes, France
[3] Policlin San Matteo, IRCCS, I-27100 Pavia, Italy
[4] Univ Saarlandes Kliniken, Homburg, Germany
[5] St Peters Hosp, Chertsey, France
关键词
cardiac resynchronization therapy; cardiac mechanical dyssynchrony; QRS duration;
D O I
10.1016/j.ejheart.2008.02.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac resynchronization therapy (CRT) is recommended for patients with NYHA class III-IV refractory heart failure (HF), ejection fraction <35% and a QRS >120 ms. We attempted to identify responders to CRT from echocardiographic (echo) indices of mechanical dyssynchrony in patients with QRS < 150 ms. Methods and results: The study enrolled 51 men and 9 women (mean age: 64.5 years) in NYHA class III (n = 54) or IV (n = 6) presenting with a mean ejection fraction: 25.7%, LV end-diastolic diameter: 69.1 mm, and QRS = 121 19 ins. All patients were implanted with a CRT system and followed for I year. Implantation was preceded and followed by clinical, functional and Doppler (D)-echo evaluation. The primary combined endpoint included 1) death from any cause, 2) HF-related hospitalisations, and 3) NYHA class at 6 months. Before implant, 27 patients had >= 1 echo criterion of mechanical dyssynchrony (DES+ group) and 33 had no evidence of dyssynchrony (DES-group). At 12 months, 8 patients (4 per group) had died, 7 from HE As regards the primary endpoint at 6 months, 33 patients (55%) bad improved, 10 (16%) were unchanged, and 17 (29%) had deteriorated. Clinical improvement was observed in 19 of 27 DES+ (70%), versus 14 of 33 DES- (42%) patients (P<0.04). Baseline QRS duration did not predict response to CRT. Conclusions: In this population of HF patients with QRS<150 ms, the presence of mechanical dyssynchrony at baseline D-echo examination, but not the QRS width, predicted 6-month clinical response to CRT. (C) 2008 Published by Elsevier B.V. on behalf of European Society of Cardiology.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 29 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Long-term effectiveness of cardiac resynchronization therapy in patients with refractory heart failure and "narrow" QRS [J].
Achilli, A ;
Sassara, M ;
Ficili, S ;
Pontillo, D ;
Achilli, P ;
Alessi, C ;
De Spirito, S ;
Guerra, R ;
Patruno, N ;
Serra, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (12) :2117-2124
[3]   Electrocardiographic predictive factors of long-term clinical improvement with multisite biventricular pacing in advanced heart failure [J].
Alonso, C ;
Leclercq, C ;
Victor, F ;
Mansour, H ;
de Place, C ;
Pavin, D ;
Carré, F ;
Mabo, P ;
Daubert, JC .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (12) :1417-1421
[4]   Doppler myocardial Imaging to evaluate the effectiveness of pacing sites in patients receiving biventricular pacing [J].
Ansalone, G ;
Giannantoni, P ;
Ricci, R ;
Trambaiolo, P ;
Fedele, F ;
Santini, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) :489-499
[5]   Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay [J].
Auricchio, A ;
Stellbrink, C ;
Sack, S ;
Block, M ;
Vogt, J ;
Bakker, P ;
Huth, C ;
Schöndube, F ;
Wolfhard, U ;
Böcker, D ;
Krahnefeld, O ;
Kirkels, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (12) :2026-2033
[6]   Intra-left ventricular electromechanical asynchrony -: A new independent predictor of severe cardiac events in heart failure patients [J].
Bader, H ;
Garrigue, S ;
Lafitte, S ;
Reuter, S ;
Jaïs, P ;
Haïssaguerre, M ;
Bonnet, J ;
Clementy, J ;
Roudaut, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (02) :248-256
[7]   Left ventricular dyssynchrony predicts benefit of cardiac resynchronization therapy in patients with end-stage heart failure before pacemaker implantation [J].
Bax, JJ ;
Marwick, TH ;
Molhoek, SG ;
Bleeker, GB ;
van Erven, L ;
Boersma, E ;
Steendijk, P ;
van der Wall, EE ;
Schalij, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (10) :1238-1240
[8]   Cardiac-resynchronization therapy in heart failure with narrow QRS complexes [J].
Beshai, John F. ;
Grimm, Richard A. ;
Nagueh, Sherif F. ;
Baker, James H., II ;
Beau, Scott L. ;
Greenberg, Steven M. ;
Pires, Luis A. ;
Tchou, Patrick J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (24) :2461-2471
[9]   Cardiac resynchronization therapy in patients with a narrow QRS complex [J].
Bleeker, Gabe B. ;
Holman, Eduard R. ;
Steendijk, Paul ;
Boersma, Eric ;
van der Wall, Ernst E. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (11) :2243-2250
[10]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150