Clinical and radiological results after parapedicular screw fixation of the thoracic spine

被引:20
作者
Vougioukas, VI
Weber, J
Scheufler, KM
机构
[1] Univ Freiburg, Dept Neurosurg, Neuroctr, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Neuroradiol, D-79106 Freiburg, Germany
关键词
thoracic spine; screw fixation; spinal instability; extrapedicular fixation;
D O I
10.3171/spi.2005.3.4.0283
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The proximity of thoracic pedicles to the spinal cord and neurovascular structures has prompted numerous efforts to obtain proper screw placement. The aim of this study was to evaluate the feasibility and efficacy of thoracic parapedicular (intercosto vertebral) screw fixation by following anatomical landmarks and using fluoroscopy. Methods. Thoracic parapedicular screw fixation was performed in 41 patients (328 screws). Postoperative computerized tomography scans were obtained in all cases to analyze the position of each screw with respect to the pedicle rib unit, the spinal canal, and the vertebral body (VB) according to a proposed novel grading system. Additionally, screw convergence angles were calculated for each instrumented level. There was no additional morbidity associated with parapedicular screw insertion. In a single case a screw suspected of entering the spinal canal was revised without causing neurological damage. The remaining screws were placed entirely within the pedicle rib unit and VB without breaching the neural foramina, pleura, or vascular structures. Conclusions. Thoracic and thoracolumbar instability can be treated adequately and safely by using parapedicular screw fixation guided by anatomical landmarks and fluoroscopic imaging. The use of computer-aided navigation may be beneficial but does not appear to be mandatory.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 27 条
[11]   An extrapedicular approach to the placement of screws in the thoracic spine: An anatomic and radiographic assessment [J].
Husted, DS ;
Yue, JJ ;
Fairchild, TA ;
Haims, AH .
SPINE, 2003, 28 (20) :2324-2330
[12]   Use of a guide device to place pedicle screws in the thoracic spine: a cadaveric study - Technical note [J].
Jang, JS ;
Lee, WB ;
Yuan, HA .
JOURNAL OF NEUROSURGERY, 2001, 94 (02) :328-333
[13]   Computer-assisted thoracic pedicle screw placement -: An in vitro feasibility study [J].
Kim, KD ;
Johnson, JP ;
Bloch, O ;
Masciopinto, JE .
SPINE, 2001, 26 (04) :360-364
[14]   Free hand pedicle screw placement in the thoracic spine: Is it safe? [J].
Kim, YJ ;
Lenke, LG ;
Bridwell, KH ;
Cho, YSS ;
Riew, KD .
SPINE, 2004, 29 (03) :333-342
[15]  
Kothe R, 2001, Spine (Phila Pa 1976), V26, pE496
[16]   Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: A biomechanical analysis [J].
Lehman, RA ;
Polly, DW ;
Kuklo, TR ;
Cunningham, B ;
Kirk, KL ;
Belmont, PJ .
SPINE, 2003, 28 (18) :2058-2065
[17]   Use of the anatomic trajectory for thoracic pedicle screw salvage after failure/violation using the straight-forward technique: A biomechanical analysis [J].
Lehman, RA ;
Kuklo, TR .
SPINE, 2003, 28 (18) :2072-2077
[18]   Pedicle morphometry in the upper thoracic spine - Limits to safe screw placement in older patients [J].
McLain, RF ;
Ferrara, L ;
Kabins, M .
SPINE, 2002, 27 (22) :2467-2471
[19]   Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance - A cadaver study [J].
Mirza, SK ;
Wiggins, GC ;
Kuntz, C ;
York, JE ;
Bellabarba, C ;
Knonodi, MA ;
Chapman, JR ;
Shaffrey, CI .
SPINE, 2003, 28 (04) :402-413
[20]   Posterior thoracic extrapedicular fixation: A biomechanical study [J].
Morgenstern, W ;
Ferguson, SJ ;
Berey, S ;
Orr, TE ;
Nolte, LP .
SPINE, 2003, 28 (16) :1829-1835