Can validated wrist devices with position sensors replace arm devices for self-home blood pressure monitoring? A randomized crossover trial using ambulatory monitoring as reference

被引:18
作者
Stergiou, George S. [1 ]
Christodoulakis, George R. [1 ]
Nasothimiou, Efthimia G. [1 ]
Giovas, Periklis P. [1 ]
Kalogeropoulos, Petros G. [1 ]
机构
[1] Third Univ Dept Med, Hypertens Ctr, Sotiria Hosp, Athens, Greece
关键词
D O I
10.1038/ajh.2008.176
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND Electronic devices that measure blood pressure (BP) at the arm level are regarded as more accurate than wrist devices and are preferred for home BP (HBP) monitoring. Recently, wrist devices with position sensors have been successfully validated using established protocols. This study assessed whether HBP values measured with validated wrist devices are sufficiently reliable to be used for making patient-related decisions in clinical practice. METHODS This randomized crossover study compared HBP measurements taken using validated wrist devices (wrist-HBP, Omron R7 with position sensor) with those taken using arm devices (arm-HBP, Omron 705IT), and also with measurements of awake ambulatory BP (ABP, Spacel-abs), in 79 subjects (36 men and 43 women) with hypertension. The mean age of the study population was 56.7 +/- 11.8 years, and 33 of the subjects were not under treatment for hypertension. RESULTS The average arm-HBP was higher than the average wrist-HBP (mean difference, systolic 5.2 +/- 9.1 mm Hg, P < 0.001, and diastolic 2.2 +/- 6.7, P < 0.01).Twenty-seven subjects (34%) had a >= 10mm Hg difference between systolic wrist-HBP and arm-HBP and twelve subjects (15%) showed similar levels of disparity in diastolic HBP readings. Strong correlations were found between arm-HBP and wrist-HBP (r0.74/0.74, systolic/diastolic, P < 0.0001). However, ABP was more strongly correlated with arm-HBP (r0.73/0.76) than with wrist-HBP (0.55/0.69). The wrist-arm HBP difference was associated with systolic ABP (r0.34) and pulse pressure (r0.29), but not with diastolic ABP, sex, age, arm circumference, and wrist circumference. CONCLUSIONS There might be important differences in HBP measured using validated wrist devices with position sensor vs. arm devices, and these could impact decisions relating to the patient in clinical practice. Measurements taken using arm devices are more closely related to ABP values than those recorded by wrist devices. More research is needed before recommending the widespread use of wrist monitors in clinical practice.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 28 条
[21]   ACCURACY OF THE SPACELABS-90207 DETERMINED BY THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL [J].
OBRIEN, E ;
MEE, F ;
ATKINS, N ;
OMALLEY, K .
JOURNAL OF HYPERTENSION, 1991, 9 (06) :573-574
[22]   Validation of the Omron M5-1, 145-1 and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension [J].
Omboni, Stefano ;
Riva, Isabella ;
Giglio, Alessia ;
Caldara, Gianluca ;
Groppelli, Antonella ;
Parati, Gianfranco .
BLOOD PRESSURE MONITORING, 2007, 12 (04) :233-242
[23]   Self blood pressure monitoring at home by wrist devices: a reliable approach? [J].
Parati, G ;
Asmar, R ;
Stergiou, GS .
JOURNAL OF HYPERTENSION, 2002, 20 (04) :573-578
[24]   Comparison of oscillometric blood pressure measurements at the wrist with an upper-arm auscultatory mercury sphygmomanometer [J].
Rogers, P ;
Burke, V ;
Stroud, P ;
Puddey, IB .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1999, 26 (5-6) :477-481
[25]   Self monitoring of blood pressure at home - Is an important adjunct to clinic measurements [J].
Stergiou, G ;
Mengden, T ;
Padfield, PL ;
Parati, G ;
O'Brien, E .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 329 (7471) :870-871
[26]   Self-monitoring of blood pressure at home: how many measurements are needed? [J].
Stergiou, GS ;
Skeva, II ;
Zourbaki, AS ;
Mountokalakis, TD .
JOURNAL OF HYPERTENSION, 1998, 16 (06) :725-731
[27]   Receptor for advanced glycation endproducts (RAGE) and the complications of diabetes [J].
Stern, DM ;
Du Yan, S ;
Yan, SF ;
Schmidt, AM .
AGEING RESEARCH REVIEWS, 2002, 1 (01) :1-15
[28]   Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT) [J].
Topouchian, Jirar A. ;
El Assaad, Mohamed A. ;
Orobinskaia, Ludmila V. ;
El Feghali, Ramzi N. ;
Asmar, Roland G. .
BLOOD PRESSURE MONITORING, 2006, 11 (03) :165-171