Experiment and simulation study on convective heat transfer of all-glass evacuated tube solar collector
被引:28
作者:
Li, Qiong
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Li, Qiong
[1
]
Gao, Wenfeng
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Gao, Wenfeng
[1
]
Lin, Wenxian
论文数: 0引用数: 0
h-index: 0
机构:
James Cook Univ, Sch Engn, Townsville, Qld 4811, AustraliaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Lin, Wenxian
[2
]
Liu, Tao
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Liu, Tao
[1
]
Zhang, Yougang
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Zhang, Yougang
[1
]
Ding, Xiang
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Ding, Xiang
[1
]
Huang, Xiaoqiao
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Huang, Xiaoqiao
[1
]
Liu, Wuming
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Phys, Beijing, Peoples R ChinaYunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
Liu, Wuming
[3
]
机构:
[1] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650500, Yunnan, Peoples R China
[2] James Cook Univ, Sch Engn, Townsville, Qld 4811, Australia
[3] Chinese Acad Sci, Inst Phys, Beijing, Peoples R China
Solar collector with horizontal double-row all-glass evacuated tubes has been extensively implemented in the solar water heating system engineering. The temperature distribution and stratification of horizontal double-row all-glass evacuated tube collector with 24 evacuated tubes have been studied. Validation of instantaneous efficiency under different declination angle theta(m) were studied by means of experiments. Moreover, numerical simulations are carried out for four different declination angle theta(m) (0 degrees/2 degrees/4 degrees/6 degrees). The results showed that the declination angle theta(m) has significant effect on energy conversion efficiency, flow patterns and stratification inside evacuated tubes. When theta(m) > 0, with the declination angle increased, the instantaneous efficiency also increased, nevertheless, the temperature stratification weakened and the heat loss coefficient demonstrated no significant change. Declination angle 6 degrees allowed to achieve significant higher temperatures, nevertheless, along with inactive area at the bottom of evacuated tubes appears. If declination angle theta(m) < 0, inversion phenomenon appears. With the increase of |theta(m)|, more heat is trapped in the sealed end of the evacuated tube, which is not conducive to the flow heat transfer in evacuated tube solar collector. (c) 2020 Elsevier Ltd. All rights reserved.