Capacitor Current Feedback-Based Active Resonance Damping Strategies for Digitally-Controlled Inductive-Capacitive-Inductive-Filtered Grid-Connected Inverters

被引:29
作者
Lorzadeh, Iman [1 ]
Abyaneh, Hossein Askarian [1 ]
Savaghebi, Mehdi [2 ]
Bakhshai, Alireza [3 ]
Guerrero, Josep M. [2 ]
机构
[1] Amirkabir Univ Technol, Dept Elect Engn, Ctr Excellence Elect Power Engn, Tehran 158754413, Iran
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[3] Queens Univ, Dept Elect & Comp Engn, Kingston, ON K7L 3N6, Canada
基金
对外科技合作项目(国际科技项目);
关键词
active resonance damping; discrete-time domain; Inductive-capacitive-inductive (LCL)-filter; current control; grid-connected inverter; VOLTAGE-SOURCE; PWM RECTIFIERS; CONTROL SCHEME; POWER FILTER; LCL; DESIGN; 3-PHASE; COMPENSATION; ROBUSTNESS; CONVERTERS;
D O I
10.3390/en9080642
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Inductive-capacitive-inductive (LCL)-type line filters are widely used in grid-connected voltage source inverters (VSIs), since they can provide substantially improved attenuation of switching harmonics in currents injected into the grid with lower cost, weight and power losses than their L-type counterparts. However, the inclusion of third order LCL network complicates the current control design regarding the system stability issues because of an inherent resonance peak which appears in the open-loop transfer function of the inverter control system near the control stability boundary. To avoid passive (resistive) resonance damping solutions, due to their additional power losses, active damping (AD) techniques are often applied with proper control algorithms in order to damp the LCL filter resonance and stabilize the system. Among these techniques, the capacitor current feedback (CCF) AD has attracted considerable attention due to its effective damping performance and simple implementation. This paper thus presents a state-of-the-art review of resonance and stability characteristics of CCF-based AD approaches for a digitally-controlled LCL filter-based grid-connected inverter taking into account the effect of computation and pulse width modulation (PWM) delays along with a detailed analysis on proper design and implementation.
引用
收藏
页数:32
相关论文
共 60 条
[1]  
[Anonymous], 51919922014 IEEE
[2]  
[Anonymous], IEEE GUID AD IEC TR
[3]  
[Anonymous], IEEE T POWER ELECT
[4]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[5]  
Beres R, 2014, APPL POWER ELECT CO, P2208, DOI 10.1109/APEC.2014.6803611
[6]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[7]   A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :542-550
[8]   Current Harmonics Compensation in Microgrids Exploiting the Power Electronics Interfaces of Renewable Energy Sources [J].
Bouloumpasis, Ioannis ;
Vovos, Panagis ;
Georgakas, Konstantinos ;
Vovos, Nicholas A. .
ENERGIES, 2015, 8 (04) :2295-2311
[9]  
Buso S., 2006, Digital Control in Power Electronics, DOI [DOI 10.2200/S00047ED1V01Y200609PEL002, 10.2200/S00047ED1V01Y200609PEL002.]
[10]   Design of a Four-Branch LCL-Type Grid-Connecting Interface for a Three-Phase, Four-Leg Active Power Filter [J].
Cao, Wu ;
Liu, Kangli ;
Ji, Yongchao ;
Wang, Yigang ;
Zhao, Jianfeng .
ENERGIES, 2015, 8 (03) :1606-1627