Safe zones and a technical guide for cerclage wiring of the femur: a computed topographic angiogram (CTA) study

被引:23
作者
Apivatthakakul, Theerachai [1 ,2 ]
Siripipattanamongkol, P. [1 ]
Oh, Chang-Wug [3 ]
Sananpanich, K. [1 ]
Phornphutkul, C. [1 ]
机构
[1] Chiang Mai Univ, Dept Orthoped, Fac Med, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Excellence Ctr Osteol Res & Training Ctr ORTC, Chiang Mai 50200, Thailand
[3] Kyungpook Natl Univ Hosp, Dept Orthopaed Surg, Daegu 700721, South Korea
关键词
Cerclage wiring; Femur; Safe zone; Technical guide; Computed topographic angiogram; INVASIVE PLATE OSTEOSYNTHESIS; FEMORAL-ARTERY; TOMOGRAPHY ANGIOGRAPHY; CADAVERIC INJECTION; FRACTURES; INJURY; CABLES; WIRES;
D O I
10.1007/s00402-017-2804-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cerclage wiring for reduction of complex femoral shaft fractures can create iatrogenic vascular injury. To describe the anatomical relation of blood vessels to the femur and develop a technical guide for safe passage of cerclage wire. CT lower-limb angiographs (CTA) of 80 patients were reviewed and analysed to identify the superficial femoral artery (SFA) and the deep femoral artery (DFA) as well as the relation of those arteries to the femoral cortex. The total length of the femur was measured and divided into eight equal segments (seven levels). At each level, the medial half of the femur was divided into eight sectors labelled A through H and the position of the SFA and DFA was recorded. The shortest distance between the femoral cortex and the SFA and DFA at each level was measured. The data was analysed using STATA version 10.0. The average total femoral length from the tip of greater trochanter to lateral joint line was 402.98 +/- 26.16 cm. The average distances from the SFA to the femur (d1) for levels 1 through 7 were 37.20 +/- 5.0, 32.09 +/- 4.74, 27.13 +/- 4.19, 27.71 +/- 5.46, 23.71 +/- 4.40, 13.63 +/- 3.59 and 10.08 +/- 3.09 mm, respectively. The average distances between the DFA and the femur (d2) for levels 1 through 3 were 26.70 +/- 4.13, 14.76 +/- 3.27 and 9.58 +/- 3.79 mm, respectively. The position of the SFA is located in sectors B through E at levels 1-3 and in sectors E through H at levels 4-7 and the position of the DFA located in sectors B through F at levels 1-3. Cerclage wiring should be started from the posterior intermuscular septum at the linea aspera. The safe area is the proximal half (midshaft) of the femur where the SFA and DFA lie at a safe distance from the femur. Between the midshaft and the distal 1/4, insertion of the passer must be done meticulously with the tip kept close to posteromedial cortex. Below the distal 1/4, the tip of the passer should be kept close to the posterior cortex to avoid injury to the SFA and the sciatic nerve.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 25 条
[1]   Case report - Superficial femoral artery injury resulting from cerclage wiring during revision THA [J].
Aleto, Thomas ;
Ritter, Merrill A. ;
Berend, Michael E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (03) :749-753
[2]   Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study [J].
Apivatthakakul, T. ;
Phaliphot, J. ;
Leuvitoonvechkit, S. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (02) :168-174
[3]   Percutaneous cerclage wiring for reduction of periprosthetic and difficult femoral fractures. A technical note [J].
Apivatthakakul, T. ;
Phornphutkul, C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06) :966-971
[4]  
Apivatthakakul T, 2009, INJ EXTRA, V40, P39
[5]   Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures [J].
Apivatthakakul, Theerachai ;
Phornphutkul, C. ;
Bunmaprasert, T. ;
Sananpanich, K. ;
Fernandez Dell'Oca, Alberto .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (06) :813-822
[6]   Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures 4 reoperations in 60 patients followed for 1 year [J].
Ban, Ilija ;
Birkelund, Lasse ;
Palm, Henrik ;
Brix, Michael ;
Troelsen, Anders .
ACTA ORTHOPAEDICA, 2012, 83 (03) :240-243
[7]   Cerclage wires or cables for the management of Intraoperative fracture associated with a cementless, tapered femoral prosthesis [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Chonko, DJ ;
Dodds, KL ;
Adams, JB .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :17-21
[8]   Cerclage cable in fracture: frustration or necessity? [J].
Cebesoy, Oguz ;
Subasi, Mehmet ;
Isik, Mustafa .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (05) :783-784
[9]  
COLBORN GL, 1995, AM SURGEON, V61, P336
[10]   A Detailed Evaluation of the Anatomical Variations of the Profunda Artery Perforator Flap Using Computed Tomographic Angiograms [J].
DeLong, Michael R. ;
Hughes, Duncan B. ;
Bond, Jennifer E. ;
Thomas, Steven M. ;
Boll, Daniel T. ;
Zenn, Michael R. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (02) :186E-192E