Transitioning Between Electronic Health Records: Effects on Ambulatory Prescribing Safety

被引:29
作者
Abramson, Erika L. [1 ,2 ,3 ,4 ]
Malhotra, Sameer [2 ,4 ]
Fischer, Karen [3 ]
Edward, Alison [2 ,4 ]
Pfoh, Elizabeth R. [2 ,4 ]
Osorio, S. Nena [1 ,3 ,4 ]
Cheriff, Adam [3 ,5 ]
Kaushal, Rainu [1 ,2 ,3 ,4 ,5 ]
机构
[1] Weill Cornell Med Coll, Dept Pediat, New York, NY 10065 USA
[2] Weill Cornell Med Coll, Dept Publ Hlth, New York, NY 10065 USA
[3] New York Presbyterian Hosp, New York, NY USA
[4] HITEC, New York, NY USA
[5] Weill Cornell Med Coll, Dept Med, New York, NY 10065 USA
基金
美国医疗保健研究与质量局;
关键词
electronic prescribing; ambulatory; transition; PHYSICIAN ORDER ENTRY; ADVERSE DRUG EVENTS; MEDICATION ERRORS; IMPACT; SYSTEMS; ALERTS; IMPLEMENTATION;
D O I
10.1007/s11606-011-1703-z
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Healthcare providers previously using older electronic health records (EHRs) with electronic prescribing (e-prescribing) are transitioning to newer systems to be eligible for federal meaningful use incentives. Little is known about the safety effects of transitioning between systems. OBJECTIVE: To assess the effect of transitioning between EHR systems on rates and types of prescribing errors, as well as provider perceptions about the effect on prescribing safety. DESIGN, PARTICIPANTS: Prospective, case study of 17 physicians at an academic-affiliated ambulatory clinic from February 2008 through August 2009. All physicians transitioned from an older EHR with minimal clinical decision support (CDS) for e-prescribing to a newer EHR with more robust CDS. MAIN MEASUREMENTS: Prescribing errors were identified by standardized prescription and chart review. A novel survey instrument was administered to evaluate provider perceptions about prescribing safety. KEY RESULTS: We analyzed 1298 prescriptions at baseline, 1331 prescriptions 12 weeks post-implementation, and 1303 prescriptions one year post-implementation. Overall prescribing error rates were highest at baseline (35.7 per 100 prescriptions, 95% confidence interval (CI) 23.2-54.8) and lowest one year post-implementation (12.2 per 100 prescriptions, 95% CI 8.6-17.4) (p < 0.001). Improvement in prescribing safety was mainly a result of reducing inappropriate abbreviation errors. However, rates for non-abbreviation prescribing errors were significantly higher at 12 weeks post-implementation than at baseline (17.7 per 100 prescriptions, 95% CI 9.5-33.0 versus 8.5 per 100 prescriptions, 95% CI 4.6-15.9) (p < 0.001) and no different at baseline than one year (10.2 per 100 prescriptions, 95% CI 6.2-18.6) (p = 0.337). Survey results complemented quantitative findings. CONCLUSIONS: Results from this case study suggest that transitioning between systems, even to those with more robust CDS, may pose important safety threats. Recognizing the challenges associated with transitions and refining CDS within systems may help maximize safety benefits.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 42 条
  • [1] ABRAMSON EL, 2011, PHYS EXPERIENC UNPUB
  • [2] The effect of electronic prescribing on medication errors and adverse drug events: A systematic review
    Ammenwerth, Elske
    Schnell-Inderst, Petra
    Machan, Christof
    Siebert, Uwe
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2008, 15 (05) : 585 - 600
  • [3] A qualitative study of the implementation of a bioinformatics tool in a biological research laboratory
    Anderson, Nicholas R.
    Ash, Joan S.
    Tarczy-Hornoch, Peter
    [J]. INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2007, 76 (11-12) : 821 - 828
  • [4] [Anonymous], 2009, PR newswire
  • [5] Bates D, 2005, CHARTERS AND CHARTER SCHOLARSHIP IN BRITAIN AND IRELAND, P1
  • [6] Effect of computerized physician order entry and a team intervention on prevention of serious medication errors
    Bates, DW
    Leape, LL
    Cullen, DJ
    Laird, N
    Petersen, LA
    Teich, JM
    Burdick, E
    Hickey, M
    Kleefield, S
    Shea, B
    Vander Vliet, M
    Seger, DL
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (15): : 1311 - 1316
  • [7] The impact of computerized physician order entry on medication error prevention
    Bates, DW
    Teich, JM
    Lee, J
    Seger, D
    Kuperman, GJ
    Ma'Luf, N
    Boyle, D
    Leape, L
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1999, 6 (04) : 313 - 321
  • [8] Recommendations for comparing electronic prescribing systems: Results of an expert consensus process
    Bell, DS
    Marken, RS
    Meili, RC
    Wang, CJ
    Rosen, M
    Brook, RH
    [J]. HEALTH AFFAIRS, 2004, 23 (04) : W305 - W317
  • [9] E-prescribing and the Medicare Modernization Act of 2003
    Bell, DS
    Friedman, MA
    [J]. HEALTH AFFAIRS, 2005, 24 (05) : 1159 - 1169
  • [10] *CERT COMM HLTH IN, 2009, CERT COMM HLTH INF T