Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement

被引:47
|
作者
Cheng, Li-Sheng [2 ]
Tsai, Ching-Yao [3 ,4 ,5 ]
Tsai, Ray Jui-Fang [6 ]
Liou, Shiow-Wen [3 ,6 ,7 ]
Ho, Jau-Der [1 ,6 ]
机构
[1] Taipei Med Univ Hosp, Dept Ophthalmol, Taipei 110, Taiwan
[2] Buddhist Tzu Chi Gen Hosp, Dept Ophthalmol, Taichung, Taiwan
[3] Taipei City Hosp, Dept Ophthalmol, Taipei, Taiwan
[4] Natl Yang Ming Univ, Community Med Res Ctr, Taipei 112, Taiwan
[5] Natl Yang Ming Univ, Inst Publ Hlth, Taipei 112, Taiwan
[6] Taipei Med Univ, Dept Ophthalmol, Taipei, Taiwan
[7] Natl Taiwan Univ, Dept Ophthalmol, Taipei 10764, Taiwan
关键词
cataract; phacoemulsification; posterior cornea; surgically induced astigmatism; KERATOMETRIC INDEX; ANTERIOR; POWER; INCISIONS; VALIDITY; PENTACAM; THICKNESS; AXIS;
D O I
10.1111/j.1755-3768.2009.01732.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of corneal surgically induced astigmatism (SIA) estimation when neglecting the posterior corneal surface measurement. Methods: Fifty right eyes undergoing phacoemulsification were measured with a rotating Scheimpflug camera (Pentacam; Oculus Inc., Wetzlar, Germany) both before and after surgery. Clear corneal incisions with one suture were used in the phacoemulsification surgery. The keratometric corneal SIA (KSIA) was derived using the anterior corneal surface measurement and the keratometric index (1.3375) while neglecting the posterior corneal surface measurement. The Pentacam-derived total corneal SIA (PSIA) was derived by vergence tracing and polar value analysis [KP(135) and KP(180)] of the measurements on both corneal surfaces. Results: The mean arithmetic estimation errors of the KSIA for the PSIA were 0.16 +/- 0.32 (-0.52 to 1.14) D for the KP(135), and) -0.02 +/- 0.30 (-0.75 to 1.29) D for the KP(180). There was a significant difference between the KP(135) components of the KSIA and PSIA. Bivariate analysis revealed a statistically significant difference between the combined means of the KSIA and PSIA. Overall, 24% had either a KP(135) component of the KSIA that differed by > 0.50 D from that of the PSIA or a KP(180) component of the KSIA that differed by > 0.50 D from that of the PSIA. The blurring strength caused by neglecting the posterior corneal measurement was > 0.50 D in 24% of eyes. Conclusion: Neglecting the posterior corneal surface measurement may lead to significant deviation in the corneal SIA estimation after phacoemulsification in a proportion of eyes.
引用
收藏
页码:417 / 422
页数:6
相关论文
共 50 条
  • [41] The comparison of corneal higher-order aberration and surgically induced astigmatism between the clear corneal incision and the limbus tunnel incision of posterior chamber implantable collamer lens implantation
    Dan, Ting-Ting
    Liu, Tai-Xiang
    Luo, Hong-yang
    Liao, Yi-Lu
    Li, Zong-Ze
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [42] The comparison of corneal higher-order aberration and surgically induced astigmatism between the clear corneal incision and the limbus tunnel incision of posterior chamber implantable collamer lens implantation
    Ting-Ting Dan
    Tai-Xiang Liu
    Hong-yang Luo
    Yi-Lu Liao
    Zong-Ze Li
    BMC Ophthalmology, 24
  • [43] Characteristics of Corneal Astigmatism of Anterior and Posterior Surface in a Normal Control Group and Patients With Keratoconus
    Shajari, Mehdi
    Friderich, Stefan
    Sadeghian, Miad Pour
    Schmack, Ingo
    Kohnen, Thomas
    CORNEA, 2017, 36 (04) : 457 - 462
  • [44] SURGICALLY INDUCED ASTIGMATISM AFTER 2.8 MM TEMPORAL AND NASAL CLEAR CORNEAL INCISIONS IN PHACOEMULSIFICATION CATARACT SURGERY OF SAME PATIENT
    Garg, Preeti
    Gupta, Chetanya P.
    Gupta, Daya Chand
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (31): : 5308 - 5313
  • [45] Comparison of surgically induced astigmatism between femtosecond laser and manual clear corneal incisions for cataract surgery
    Diakonis, Vasilios F.
    Yesilirmak, Nilufer
    Cabot, Florence
    Kankariya, Vardhaman P.
    Kounis, George A.
    Warren, Daniel
    Sayed-Ahmed, Ibrahim O.
    Yoo, Sonia H.
    Donaldson, Kendall
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10) : 2075 - 2080
  • [46] Tomographic analysis of anterior and posterior surgically induced astigmatism after 2.2 mm temporal clear corneal incisions in femtosecond laser-assisted cataract surgery
    Kohnen, Thomas
    Loeffler, Franziska
    Herzog, Michael
    Petermann, Kerstin
    Boehm, Myriam
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) : 1602 - 1611
  • [47] Effects of clear corneal incision location and morphology on corneal surgically induced astigmatism and higher-order aberrations after ICL V4c implantation
    Wang, Jun
    He, Xiaoying
    He, Qin
    Han, Jin
    Yang, Zixuan
    Wang, Xuze
    Han, Wei
    FRONTIERS IN MEDICINE, 2024, 11
  • [48] The influence of corneal incision size on endothelial cell loss and surgically induced astigmatism following phacoemulsification cataract surgery
    Hepokur, Mustafa
    Kizilay, Esra Bulut
    Durmus, Ebubekir
    Aykut, Veysel
    Esen, Fehim
    Oguz, Halit
    NORTHERN CLINICS OF ISTANBUL, 2022, 9 (04) : 385 - 390
  • [49] Comparative analysis of surgically induced astigmatism following cataract surgery: influence of previous myopic correction and corneal parameters
    Mularoni, Alessandro
    Date, Purva
    Banno, Paola
    Avitabile, Teresio
    Marcheggiani, Eleonora Benedetta
    Forlini, Matteo
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [50] Postoperative Corneal and Surgically Induced Astigmatism following Superior Approach Manual Small Incision Cataract Surgery in Patients with Preoperative Against-the-Rule Astigmatism
    Arthur, Edmund
    Sadik, Ahmed Abdul
    Ben Kumah, David
    Osae, Eugene Appenteng
    Mireku, Felix Agyemang
    Asiedu, Frank Yeboah
    Ablordeppey, Reynolds Kwame
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016