cataract; phacoemulsification; posterior cornea; surgically induced astigmatism; KERATOMETRIC INDEX; ANTERIOR; POWER; INCISIONS; VALIDITY; PENTACAM; THICKNESS; AXIS;
D O I
10.1111/j.1755-3768.2009.01732.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of corneal surgically induced astigmatism (SIA) estimation when neglecting the posterior corneal surface measurement. Methods: Fifty right eyes undergoing phacoemulsification were measured with a rotating Scheimpflug camera (Pentacam; Oculus Inc., Wetzlar, Germany) both before and after surgery. Clear corneal incisions with one suture were used in the phacoemulsification surgery. The keratometric corneal SIA (KSIA) was derived using the anterior corneal surface measurement and the keratometric index (1.3375) while neglecting the posterior corneal surface measurement. The Pentacam-derived total corneal SIA (PSIA) was derived by vergence tracing and polar value analysis [KP(135) and KP(180)] of the measurements on both corneal surfaces. Results: The mean arithmetic estimation errors of the KSIA for the PSIA were 0.16 +/- 0.32 (-0.52 to 1.14) D for the KP(135), and) -0.02 +/- 0.30 (-0.75 to 1.29) D for the KP(180). There was a significant difference between the KP(135) components of the KSIA and PSIA. Bivariate analysis revealed a statistically significant difference between the combined means of the KSIA and PSIA. Overall, 24% had either a KP(135) component of the KSIA that differed by > 0.50 D from that of the PSIA or a KP(180) component of the KSIA that differed by > 0.50 D from that of the PSIA. The blurring strength caused by neglecting the posterior corneal measurement was > 0.50 D in 24% of eyes. Conclusion: Neglecting the posterior corneal surface measurement may lead to significant deviation in the corneal SIA estimation after phacoemulsification in a proportion of eyes.
引用
收藏
页码:417 / 422
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF CORNEAL PACHYMETRY CHANGES AND SURGICALLY INDUCED ASTIGMATISM OF MICROCOAXIAL PHACOEMULSIFICATION SURGERY AND COAXIAL PHACOEMULSIFICATION SURGERY
    Altikurt, Emre
    Gozum, Nilufer
    Cebeci, Zafer
    Tas, Aye Yildiz
    Gucukoglu, Ahmet
    JOURNAL OF ISTANBUL FACULTY OF MEDICINE-ISTANBUL TIP FAKULTESI DERGISI, 2018, 81 (03): : 77 - 83
  • [32] Measurement centration and zone diameter in anterior, posterior and total corneal astigmatism in keratoconus
    Fredriksson, Anneli
    Behndig, Anders
    ACTA OPHTHALMOLOGICA, 2017, 95 (08) : 826 - 833
  • [33] Effect of the posterior corneal surface on total corneal astigmatism in patients with age-related cataract
    Ying-Ying Jin
    Zhen Zhou
    Xiao-Yong Yuan
    Hui Song
    Xin Tang
    International Journal of Ophthalmology, 2018, (06) : 958 - 965
  • [34] Correction of Asymmetric Bowtie Corneal Astigmatism with a Toric Intraocular Lens: Outcomes and Accuracy of Measurement Modes
    Li, Hao
    He, Wenwen
    Guo, Donglin
    Fang, Yanwen
    Meng, Jiaqi
    Zhang, Keke
    Zhu, Xiangjia
    Lu, Yi
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (03):
  • [35] Accuracy of Toric Intraocular Lens Formulas With Measured Posterior Corneal Astigmatism of Different Orientations
    Stewart, Stephen
    Yeo, Tun Kuan
    Moutari, Salissou
    McNeely, Richard
    Moore, Jonathan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 266 : 26 - 36
  • [36] Effect of Diabetes on Surgically Induced Astigmatism in 4 mm Corneal Tunnel Phacoemulsification Surgery
    Sevim, Sahin
    Gencer, Suleyman
    Sakaoglu, Naci
    Uludogan, Gursel
    Acar, Suphi
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2005, 35 (01): : 23 - 28
  • [37] Site of clear corneal incision in cataract surgery and its effects on surgically induced astigmatism
    Piao, Junjie
    Joo, Choun-Ki
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [38] Effect of Corneal Incision Enlargement on Surgically Induced Astigmatism in Biaxial Microincision Cataract Surgery
    Tetikoglu, Mehmet
    Yeter, Celal
    Helvacioglu, Firat
    Aktas, Serdar
    Sagdik, Haci Murat
    Ozcura, Fatih
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2016, 46 (03): : 99 - 103
  • [39] Surgically induced astigmatism after 3.0 mm temporal and nasal clear corneal incisions in bilateral cataract surgery
    Yoon, Je Hwan
    Kim, Kyun-Hyung
    Lee, Jong Yeon
    Nam, Dong Heun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (11) : 645 - 648
  • [40] The Influence of Corneal Thickness on Surgically Induced Corneal Astigmatism Derived from Total Keratometry Measured by Anterior Segment Swept-Source OCT
    Zhao, Fangyu
    Yin, Yufan
    Pazo, Emmanuel Eric
    Tian, Fang
    Jiang, Yuanfeng
    Bu, Shaochong
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (09) : 2381 - 2391