Feasibility of sub-dermal soft tissue deformation assessment using B-mode ultrasound for pressure ulcer prevention

被引:8
|
作者
Doridam, J. [1 ,3 ]
Macron, A. [1 ,2 ]
Vergari, C. [1 ]
Verney, A. [2 ]
Rohan, P. -Y. [1 ]
Pillet, H. [1 ]
机构
[1] LBM Inst Biomecan Humaine Georges Charpak, Arts & Metiers ParisTech, 151 Bd Hop, F-75013 Paris, France
[2] CEA, LIST, Interact Robot Lab, F-91191 Gif Sur Yvette, France
[3] Univ Paris XIII, Dept Anat, UFR Sante Med Biol Humaine, Bobigny, France
关键词
pressure ulcer; Ultrasound; Subdermal soft tissue; Strains; SPINAL-CORD-INJURY; MUSCLE; COMPRESSION; STRAINS; DAMAGE; DEEP; ISCHEMIA; PATTERNS; BUTTOCKS; RISK;
D O I
10.1016/j.jtv.2018.08.002
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Pressure Ulcer (PU) prevention remains a main public health issue. The physio-pathology of this injury is not fully understood, and a satisfactory therapy is currently not available. Recently, several works suggested that mechanical strains are responsible of deformation-induced damage involved in the initiation of Deep Tissue Injury (DTI). A better assessment of the internal behavior could allow to enhance the modeling of the transmission of loads into the different structures composing the buttock. A few studies focused on the experimental in vivo buttock deformation quantification using Magnetic Resonance Imaging (MRI), but its use has important drawbacks. In clinical practice, ultrasound imaging is an accessible, low cost, and real-time technic to study the soft tissue. The objective of the present work was to show the feasibility of using B-mode ultrasound imaging for the quantification of localised soft-tissue strains of buttock tissues during sitting. An original protocol was designed, and the intra-operator reliability of the method was assessed. Digital Image Correlation was used to compute the displacement field of the soft tissue of the buttock during a full realistic loading while sitting. Reference data of the strains in the frontal and sagittal planes under the ischium were reported for a population of 7 healthy subjects. The average of shear strains over the region of interest in the fat layer reached levels up to 117% higher than the damage thresholds previously quantified for the muscular tissue in rats. In addition, the observation of the muscles displacements seems to confirm previous results which already reported the absence of muscular tissue under the ischium in the seated position, questioning the assumption commonly made in Finite Element modeling that deep tissue injury initiates in the muscle underlying the bone.
引用
收藏
页码:238 / 243
页数:6
相关论文
共 9 条
  • [1] Reliability of B-mode ultrasound and shear wave elastography in evaluating sacral bone and soft tissue characteristics in young adults with clinical feasibility in elderly
    Abou Karam, Maher
    Mukhina, Ekaterina
    Daras, Nils
    Rivals, Isabelle
    Pillet, Helene
    Skalli, Wafa
    Connesson, Nathanael
    Payan, Yohan
    Rohan, Pierre-Yves
    JOURNAL OF TISSUE VIABILITY, 2022, 31 (02) : 245 - 254
  • [2] Real-Time Finite Element Monitoring of Sub-Dermal Tissue Stresses in Individuals with Spinal Cord Injury: Toward Prevention of Pressure Ulcers
    Linder-Ganz, Eran
    Yarnitzky, Gilad
    Yizhar, Ziva
    Siev-Ner, Itzhak
    Gefen, Amit
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (02) : 387 - 400
  • [3] LIVER FIBROSIS ASSESSMENT USING TRANSIENT ELASTOGRAPHY GUIDED WITH REAL-TIME B-MODE ULTRASOUND IMAGING: A FEASIBILITY STUDY
    Mak, Tak-Man
    Huang, Yan-Ping
    Zheng, Yong-Ping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (06) : 956 - 966
  • [4] Technical considerations for accurate measurement of subcutaneous adipose tissue thickness using B-mode ultrasound
    Toomey, C.
    McCreesh, K.
    Leahy, S.
    Jakeman, P.
    ULTRASOUND, 2011, 19 (02) : 91 - 96
  • [5] Assessment of carotid atherosclerosis from B-mode ultrasound images using directional multiscale texture features
    Tsiaparas, N. N.
    Golemati, S.
    Andreadis, I.
    Stoitsis, J.
    Valavanis, I.
    Nikita, K. S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (11)
  • [6] Feasibility of high-frequency ultrasound for seminiferous tubule assessment and correlation of B-mode imaging with pathological findings in the testis in azoospermia
    Ohta, Tomoyuki
    Kojo, Kosuke
    Kurobe, Masahiro
    Numahata, Daisuke
    Tatsuya, Takayama
    Okada, Shinya
    Iwamoto, Teruaki
    JOURNAL OF MEDICAL ULTRASONICS, 2024, 51 (03) : 465 - 475
  • [7] Liver Fibrosis Assessment Using Transient Elastography Guided with Real-Time B-Mode Ultrasound Imaging
    Zheng, Yong-Ping
    Mak, Tak-Man
    Huang, Zheng-Ming
    Cheung, Chung-Wai James
    Zhou, Yong-Jin
    He, Jun-Feng
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1036 - 1039
  • [8] Assessment of Early Therapy Response of Non-Hodgkin's and Hodgkin's Lymphoma Using B-Mode Ultrasound and Dynamic Contrast-Enhanced Ultrasound
    Trenker, Corinna
    Kuempel, Jessica
    Michel, Christian
    Zadeh, Ehsan Safai
    Dietrich, Christoph F.
    Timmesfeld, Nina
    Neubauer, Andreas
    Burchert, Andreas
    Goerg, Christian
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (08) : 2033 - 2040
  • [9] Assessment of Human Instantaneous Arterial Diameter Using B-Mode Ultrasound Imaging and Artificial Neural Networks: Determination of Wall Mechanical Properties
    Pessana, F.
    Venialgo, E.
    Rubstein, J.
    Furfaro, A.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1409 - 1412