Initial experience with three-dimensional heads-up display system for cataract surgery - A comparative study

被引:13
作者
Kelkar, Jai A. [1 ]
Kelkar, Aditya S. [1 ]
Bolisetty, Mounika [1 ]
机构
[1] Natl Inst Ophthalmol, Dept Ophthalmol, Pune, Maharashtra, India
关键词
Conventional microscope; phacoemulsification; viewing system; 3-D Heads up display system; NATIONAL-SURVEY; BACK; PAIN;
D O I
10.4103/ijo.IJO_231_21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the complication rates, surgical time and learning curve using the 3-D Heads up display system in comparison with the conventional microscope for routine cataract surgery. Methods: Consecutive consenting adults with uncomplicated cataract were offered phacoemulsification using the 3-D Heads up display system (ARTEVO 800 Carl Zeiss Meditec) or the conventional microscope (Zeiss Lumera 700) by two experienced surgeons. Surgical time, measured from start of corneal incision to removal of microscope from the surgical field and complication rates were compared between the groups. Results: Of the 343 eyes enrolled, 100 (29%) underwent surgery using the 3-D Heads up display system. The surgical time for 3-D Heads up display system was significantly higher in the 3-D group (8.4 +/- 2.1 vs. 6.5 +/- 1.8 minutes, P < 0.001). There were no group differences in surgical complications (2% in 3-D vs. 2.5% in conventional microscope, P = 0.28). Comparing across 4 quartiles within the 3-D group, the mean surgical time was slightly higher during the 1st quartile (n = 25, 9.1 +/- 1.9 minutes) compared to the last quartile (n = 25, 8.2 +/- 1.9 minutes) (p = 0.17). Complications in the 3-D group occurred only in the initial 50% of cases. Seven (7%) cases in the 3-D group were converted to conventional binocular microscope of which 3 each were due to difficulty in depth perception and low illumination while one was due to intraoperative pupillary constriction. Conclusion: Phacoemulsification with the 3-D Heads up display system takes longer time but offers excellent visualization, ergonomics and safety compared to conventional microscopes. Experienced surgeons should be able to adapt easily after their first 50 surgeries.
引用
收藏
页码:2304 / +
页数:6
相关论文
共 18 条
[1]   Comparing Heads-Up versus Binocular Microscope Visualization Systems in Anterior and Posterior Segment Surgeries: A Retrospective Study [J].
Berquet, Florence ;
Henry, Adrien ;
Barbe, Coralie ;
Cheny, Thibault ;
Afriat, Mickael ;
Benyelles, Abdel-Karim ;
Bartolomeu, David ;
Arndt, Carl .
OPHTHALMOLOGICA, 2020, 243 (05) :347-354
[2]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[3]   HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES An Experimental and Clinical Study [J].
Eckardt, Claus ;
Paulo, Erica B. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (01) :137-147
[4]   RESOLUTION, DEPTH OF FIELD, AND PHYSICIAN SATISFACTION DURING DIGITALLY ASSISTED VITREORETINAL SURGERY [J].
Freeman, William R. ;
Chen, Kevin C. ;
Ho, Joseph ;
Chao, Daniel L. ;
Ferreyra, Henry A. ;
Tripathi, A. Burton ;
Nudleman, Eric ;
Bartsch, Dirk-Uwe .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (09) :1768-1771
[5]   National survey of back & neck pain amongst consultant ophthalmologists in the United Kingdom [J].
Hyer, Jonathan N. ;
Lee, Richard M. ;
Chowdhury, Haziq R. ;
Smith, Henry B. ;
Dhital, Anish ;
Khandwala, Mona .
INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (06) :769-775
[6]   Three-dimensional heads up display in anterior segment surgeries- Expanding frontiers in the COVID-19 era [J].
Kaur, Manpreet ;
Titiyal, Jeewan S. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) :2338-2340
[7]   Heads-Up 3D Surgery under Low Light Intensity Conditions: New High-Sensitivity HD Camera for Ophthalmological Microscopes [J].
Matsumoto, Celso Soiti ;
Shibuya, Masayuki ;
Makita, Jun ;
Shoji, Takuhei ;
Ohno, Hisato ;
Shinoda, Kei ;
Matsumoto, Harue .
JOURNAL OF OPHTHALMOLOGY, 2019, 2019
[8]  
Miyake K, 1999, ARCH OPHTHALMOL-CHIC, V117, P1623
[9]   Comparison of microscopic illumination between a three-dimensional heads-up system and eyepiece in cataract surgery [J].
Nariai, Yui ;
Horiguchi, Masayuki ;
Mizuguchi, Tadashi ;
Sakurai, Ryota ;
Tanikawa, Atsuhiro .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) :1817-1821
[10]   Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries [J].
Ohno, Hisato .
CLINICAL OPHTHALMOLOGY, 2019, 13 :2071-2073