A deep learning-based whole-body solution for PET/MRI attenuation correction

被引:8
作者
Ahangari, Sahar [1 ,2 ]
Olin, Anders Beck [1 ,2 ]
Federspiel, Marianne Kinggard [1 ,2 ]
Jakoby, Bjoern [3 ]
Andersen, Thomas Lund [1 ,2 ]
Hansen, Adam Espe [1 ,2 ,4 ,5 ]
Fischer, Barbara Malene [1 ,2 ,4 ]
Andersen, Flemming Littrup [1 ,2 ,4 ]
机构
[1] Rigshosp, Dept Clin Physiol, Nucl Med, Copenhagen, Denmark
[2] Rigshosp, PET, Copenhagen, Denmark
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
PET; MRI; MR-AC; Attenuation correction; Deep learning; Whole body; QUANTITATIVE-EVALUATION; MRI; TRUNCATION;
D O I
10.1186/s40658-022-00486-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. Materials and methods Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. Results Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R-2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. Conclusions Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.
引用
收藏
页数:15
相关论文
共 43 条
  • [11] Dosimetric evaluation of an atlas-based synthetic CT generation approach for MR-only radiotherapy of pelvis anatomy
    Farjam, Reza
    Tyag, Neelam
    Deasy, Joseph O.
    Hun, Margie A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 101 - 109
  • [12] Ge Y., 2019, UNPAIRED WHOLE BODY, P4
  • [13] Gong K, 2021, IEEE T RADIAT PLASMA, V5, P185, DOI [10.1109/TRPMS.2020.3006844, 10.1109/trpms.2020.3006844]
  • [14] Evaluation of improved attenuation correction in whole-body PET/MR on patients with bone metastasis using various radiotracers
    Grafe, Hong
    Lindemann, Maike E.
    Ruhlmann, Verena
    Oehmigen, Mark
    Hirmas, Nader
    Umutlu, Lale
    Herrmann, Ken
    Quick, Harald H.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (10) : 2269 - 2279
  • [15] MR-based synthetic CT generation using a deep convolutional neural network method
    Han, Xiao
    [J]. MEDICAL PHYSICS, 2017, 44 (04) : 1408 - 1419
  • [16] MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods
    Hofmann, Matthias
    Bezrukov, Ilja
    Mantlik, Frederic
    Aschoff, Philip
    Steinke, Florian
    Beyer, Thomas
    Pichler, Bernd J.
    Schoelkopf, Bernhard
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (09) : 1392 - 1399
  • [17] Hwang D, 2019, J NUCL MED, V60
  • [18] Generation of PET Attenuation Map for Whole-Body Time-of-Flight 18F-FDG PET/MRI Using a Deep Neural Network Trained with Simultaneously Reconstructed Activity and Attenuation Maps
    Hwang, Donghwi
    Kang, Seung Kwan
    Kim, Kyeong Yun
    Seo, Seongho
    Paeng, Tin Chul
    Lee, Dong Soo
    Lee, Jae Sung
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (08) : 1183 - 1189
  • [19] Keereman V, 2010, J NUCL MED, V51, P812, DOI 10.2967/jnumed.109.065425
  • [20] Region specific optimization of continuous linear attenuation coefficients based on UTE (RESOLUTE): application to PET/MR brain imaging
    Ladefoged, Claes N.
    Benoit, Didier
    Law, Ian
    Holm, Soren
    Kjaer, Andreas
    Hojgaard, Liselotte
    Hansen, Adam E.
    Andersen, Flemming L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 8047 - 8065