A deep learning-based whole-body solution for PET/MRI attenuation correction

被引:8
作者
Ahangari, Sahar [1 ,2 ]
Olin, Anders Beck [1 ,2 ]
Federspiel, Marianne Kinggard [1 ,2 ]
Jakoby, Bjoern [3 ]
Andersen, Thomas Lund [1 ,2 ]
Hansen, Adam Espe [1 ,2 ,4 ,5 ]
Fischer, Barbara Malene [1 ,2 ,4 ]
Andersen, Flemming Littrup [1 ,2 ,4 ]
机构
[1] Rigshosp, Dept Clin Physiol, Nucl Med, Copenhagen, Denmark
[2] Rigshosp, PET, Copenhagen, Denmark
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
PET; MRI; MR-AC; Attenuation correction; Deep learning; Whole body; QUANTITATIVE-EVALUATION; MRI; TRUNCATION;
D O I
10.1186/s40658-022-00486-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. Materials and methods Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. Results Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R-2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. Conclusions Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.
引用
收藏
页数:15
相关论文
共 43 条
  • [1] Multi-parametric PET/MRI for enhanced tumor characterization of patients with cervical cancer
    Ahangari, Sahar
    Andersen, Flemming Littrup
    Hansen, Naja Liv
    Nottrup, Trine Jakobi
    Berthelsen, Anne Kiil
    Kallehauge, Jesper Folsted
    Vogelius, Ivan Richter
    Kjaer, Andreas
    Hansen, Adam Espe
    Fischer, Barbara Malene
    [J]. EUROPEAN JOURNAL OF HYBRID IMAGING, 2022, 6 (01):
  • [2] Toward PET/MRI as one-stop shop for radiotherapy planning in cervical cancer patients
    Ahangari, Sahar
    Hansen, Naja Liv
    Olin, Anders Beck
    Nottrup, Trine Jakobi
    Ryssel, Heidi
    Berthelsen, Anne Kiil
    Lofgren, Johan
    Loft, Annika
    Vogelius, Ivan Richter
    Schnack, Tine
    Jakoby, Bjoern
    Kjaer, Andreas
    Andersen, Flemming Littrup
    Fischer, Barbara Malene
    Hansen, Adam Espe
    [J]. ACTA ONCOLOGICA, 2021, 60 (08) : 1045 - 1053
  • [3] MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers
    Arabi, Hossein
    Zaidi, Habib
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 686 - 701
  • [4] Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET/MRI
    Arabi, Hossein
    Zeng, Guodong
    Zheng, Guoyan
    Zaidi, Habib
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (13) : 2746 - 2759
  • [5] MR-Based Field-of-View Extension in MR/PET: B0 Homogenization Using Gradient Enhancement (HUGE)
    Blumhagen, Jan O.
    Ladebeck, Ralf
    Fenchel, Matthias
    Scheffler, Klaus
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 1047 - 1057
  • [6] Feasibility of Deep Learning-Based PET/MR Attenuation Correction in the Pelvis Using Only Diagnostic MR Images
    Bradshaw, Tyler J.
    Zhao, Gengyan
    Jang, Hyungseok
    Liu, Fang
    McMillan, Alan B.
    [J]. TOMOGRAPHY, 2018, 4 (03) : 138 - 147
  • [7] The effect of limited MR field of view in MR/PET attenuation correction
    Delso, Gaspar
    Martinez-Moeller, Axel
    Bundschuh, Ralph A.
    Nekolla, Stephan G.
    Ziegler, Sibylle I.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2804 - 2812
  • [8] Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging
    Dong, Xue
    Lei, Yang
    Wang, Tonghe
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)
  • [9] Synthetic CT generation from non-attenuation corrected PET images for whole-body PET imaging
    Dong, Xue
    Wang, Tonghe
    Lei, Yang
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)
  • [10] The promise of multiparametric imaging in oncology: how do we move forward?
    Even, Aniek J. G.
    De Ruysscher, Dirk
    van Elmpt, Wouter
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (07) : 1195 - 1198