A deep learning-based whole-body solution for PET/MRI attenuation correction

被引:12
作者
Ahangari, Sahar [1 ,2 ]
Olin, Anders Beck [1 ,2 ]
Federspiel, Marianne Kinggard [1 ,2 ]
Jakoby, Bjoern [3 ]
Andersen, Thomas Lund [1 ,2 ]
Hansen, Adam Espe [1 ,2 ,4 ,5 ]
Fischer, Barbara Malene [1 ,2 ,4 ]
Andersen, Flemming Littrup [1 ,2 ,4 ]
机构
[1] Rigshosp, Dept Clin Physiol, Nucl Med, Copenhagen, Denmark
[2] Rigshosp, PET, Copenhagen, Denmark
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
PET; MRI; MR-AC; Attenuation correction; Deep learning; Whole body; QUANTITATIVE-EVALUATION; MRI; TRUNCATION;
D O I
10.1186/s40658-022-00486-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. Materials and methods Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. Results Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R-2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. Conclusions Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.
引用
收藏
页数:15
相关论文
共 43 条
[1]   Multi-parametric PET/MRI for enhanced tumor characterization of patients with cervical cancer [J].
Ahangari, Sahar ;
Andersen, Flemming Littrup ;
Hansen, Naja Liv ;
Nottrup, Trine Jakobi ;
Berthelsen, Anne Kiil ;
Kallehauge, Jesper Folsted ;
Vogelius, Ivan Richter ;
Kjaer, Andreas ;
Hansen, Adam Espe ;
Fischer, Barbara Malene .
EUROPEAN JOURNAL OF HYBRID IMAGING, 2022, 6 (01)
[2]   Toward PET/MRI as one-stop shop for radiotherapy planning in cervical cancer patients [J].
Ahangari, Sahar ;
Hansen, Naja Liv ;
Olin, Anders Beck ;
Nottrup, Trine Jakobi ;
Ryssel, Heidi ;
Berthelsen, Anne Kiil ;
Lofgren, Johan ;
Loft, Annika ;
Vogelius, Ivan Richter ;
Schnack, Tine ;
Jakoby, Bjoern ;
Kjaer, Andreas ;
Andersen, Flemming Littrup ;
Fischer, Barbara Malene ;
Hansen, Adam Espe .
ACTA ONCOLOGICA, 2021, 60 (08) :1045-1053
[3]   MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers [J].
Arabi, Hossein ;
Zaidi, Habib .
MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) :686-701
[4]   Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET/MRI [J].
Arabi, Hossein ;
Zeng, Guodong ;
Zheng, Guoyan ;
Zaidi, Habib .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (13) :2746-2759
[5]   MR-Based Field-of-View Extension in MR/PET: B0 Homogenization Using Gradient Enhancement (HUGE) [J].
Blumhagen, Jan O. ;
Ladebeck, Ralf ;
Fenchel, Matthias ;
Scheffler, Klaus .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) :1047-1057
[6]   Feasibility of Deep Learning-Based PET/MR Attenuation Correction in the Pelvis Using Only Diagnostic MR Images [J].
Bradshaw, Tyler J. ;
Zhao, Gengyan ;
Jang, Hyungseok ;
Liu, Fang ;
McMillan, Alan B. .
TOMOGRAPHY, 2018, 4 (03) :138-147
[7]   The effect of limited MR field of view in MR/PET attenuation correction [J].
Delso, Gaspar ;
Martinez-Moeller, Axel ;
Bundschuh, Ralph A. ;
Nekolla, Stephan G. ;
Ziegler, Sibylle I. .
MEDICAL PHYSICS, 2010, 37 (06) :2804-2812
[8]   Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging [J].
Dong, Xue ;
Lei, Yang ;
Wang, Tonghe ;
Higgins, Kristin ;
Liu, Tian ;
Curran, Walter J. ;
Mao, Hui ;
Nye, Jonathon A. ;
Yang, Xiaofeng .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)
[9]   Synthetic CT generation from non-attenuation corrected PET images for whole-body PET imaging [J].
Dong, Xue ;
Wang, Tonghe ;
Lei, Yang ;
Higgins, Kristin ;
Liu, Tian ;
Curran, Walter J. ;
Mao, Hui ;
Nye, Jonathon A. ;
Yang, Xiaofeng .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)
[10]   The promise of multiparametric imaging in oncology: how do we move forward? [J].
Even, Aniek J. G. ;
De Ruysscher, Dirk ;
van Elmpt, Wouter .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (07) :1195-1198