Evaluation of computed tomography dose profiler probe for computed tomography dose index and geometric efficiency measurements

被引:2
作者
Akhilesh, Philomina [1 ]
Pathan, M. S. [1 ]
Sharma, S. D. [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
关键词
CT dose profiler; solid state sensor; CTDI100; metric; geometric efficiency; radiochromic film; CT; DOSIMETRY;
D O I
10.1088/2057-1976/ac8e71
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the performance of solid-state sensor based computed tomography dose profiler (CTDP) probe for measurement of standard computed tomography dose metric CTDI100 and free in air geometric efficiency for various beam widths available in a 128-slice CT scanner and also to estimate the efficiency of CTDI100 metric. The response accuracy of CTDP probe was verified using a standard 100 mm long ionization chamber. The geometric efficiency measurements performed by the CTDP probe were validated using XR-QA2 radiochromic film measurements. The efficiency of CTDI100 metric was assessed by calculating the ratio of CTDI100 measured in the center hole position to CTDI infinity measured in the same position of both head and body phantoms. The weighted CTDI values derived from CTDI100 measured by the CTDP probe showed an average difference of 8% from ionization chamber measured values. The efficiency of CTDI100 metric estimated using CTDP probe and 150 mm long phantoms was in the range of 82% to 86% and 76% to 80% for head and body phantom measurements respectively. The differences in the geometric efficiency values for various beam settings and tube voltages measured by the CTDP probe and films were within 7%. Taken together, the results of this study proved that unlike the 100 mm long ionization chamber, the CTDP probe can be efficiently used to determine CTDI for any length over which dose integration is desired and also measure geometric efficiency of MDCT scanners for various beam widths in helical mode of operation.
引用
收藏
页数:10
相关论文
共 21 条
[1]  
ABAQUS, 2014, PROFILER USERS MANUA
[2]   ESTIMATION OF EYE LENS DOSE DURING BRAIN SCANS USING GAFCHROMIC XR-QA2 FILM IN VARIOUS MULTIDETECTOR CT SCANNERS [J].
Akhilesh, Philomina ;
Kulkarni, Arti R. ;
Jamhale, Shramika H. ;
Sharma, S. D. ;
Kumar, Rajesh ;
Datta, D. .
RADIATION PROTECTION DOSIMETRY, 2017, 174 (02) :236-241
[3]  
[Anonymous], 2008, MEASUREMENT REPORTIN
[4]  
[Anonymous], 2009, IEC 60601-2-44 ed3.0
[5]   CT dosimetry: comparison of measurement techniques and devices [J].
Bauhs, John A. ;
Vrieze, Thomas J. ;
Primak, Andrew N. ;
Bruesewitz, Michael R. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2008, 28 (01) :245-253
[6]   Comparison of methods for assessing geometric efficiency on multi-detector CT scanners [J].
Berris, Theocharis ;
Perisinakis, Kostas ;
Papadakis, Antonios E. ;
Damilakis, John .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (03) :312-322
[7]   The trouble with CTDI100 [J].
Boone, John M. .
MEDICAL PHYSICS, 2007, 34 (04) :1364-1371
[8]   Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography [J].
Chuang, Chun-Chao ;
Wu, Jay .
SCIENTIFIC REPORTS, 2018, 8
[9]  
Gronlund E., 2013, CALIBRATION CLIN MEA
[10]  
International Electrotechnical Commission, 2002, INT STANDARD AMENDME