Performance enhancements of compound semiconductor radiation detectors using digital pulse processing techniques

被引:24
作者
Abbene, L. [1 ]
Gerardi, G. [1 ]
机构
[1] Univ Palermo, Dipartimento Fis, I-90128 Palermo, Italy
关键词
Compound semiconductors; CdTe detectors; X-ray and gamma ray spectroscopy; Digital pulse processing; Pulse height analysis; Pulse shape analysis; X-RAY SPECTROSCOPY; CDTE DETECTOR; GAMMA; RESOLUTION; MAMMOGRAPHY; PROGRESS;
D O I
10.1016/j.nima.2011.06.107
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The potential benefits of using compound semiconductors for X-ray and gamma ray spectroscopy are already well known. Radiation detectors based on high atomic number and wide band gap compound semiconductors show high detection efficiency and good spectroscopic performance even at room temperature. Despite these appealing properties, incomplete charge collection is a critical issue. Generally, incomplete charge collection, mainly due to the poor transport properties of the holes, produces energy resolution worsening and the well known hole tailing in the measured spectra. In this work, we present a digital pulse processing (DPP) system for high resolution spectroscopy with compound semiconductor radiation detectors. The DPP method, implemented on a PC platform, performs a height and shape analysis of the detector pulses (preamplifier output pulses), digitized by a 14-bit, 100 MHz ADC. Fast and slow shaping, automatic pole-zero adjustment, baseline restoration and pile-up rejection allow precise pulse height measurements both at low and high counting rate environments. Pulse shape analysis techniques (pulse shape discrimination, linear and nonlinear pulse shape corrections) to compensate for incomplete charge collection were also implemented. The results of spectroscopic measurements on a planar CdTe detector show the high potentialities of the system, obtaining low tailing in the measured spectra and energy resolution quite close to the theoretical limit. High-rate measurements (up to 820 kcps) exhibit the excellent performance of the pulse height analysis and the benefits of pulse shape techniques for peak pile-up reduction in the measured spectra. This work was carried out in the framework of the development of portable X-ray spectrometers for both laboratory research and medical applications. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:340 / 348
页数:9
相关论文
共 40 条
  • [1] Spectroscopic response of a CdZnTe multiple electrode detector
    Abbene, L.
    Del Sordo, S.
    Fauci, F.
    Gerardi, G.
    La Manna, A.
    Raso, G.
    Cola, A.
    Perillo, E.
    Raulo, A.
    Gostilo, V.
    Stumbo, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (2-3) : 324 - 331
  • [2] High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach
    Abbene, L.
    Gerardi, G.
    Principato, F.
    Del Sordo, S.
    Ienzi, R.
    Raso, G.
    [J]. MEDICAL PHYSICS, 2010, 37 (12) : 6147 - 6156
  • [3] Performance of a digital CdTe X-ray spectrometer in low and high counting rate environment
    Abbene, L.
    Gerardi, G.
    Del Sordo, S.
    Raso, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3) : 447 - 452
  • [4] Hard x-ray response of pixellated CdZnTe detectors
    Abbene, L.
    Del Sordo, S.
    Caroli, E.
    Gerardi, G.
    Raso, G.
    Caccia, S.
    Bertuccio, G.
    [J]. JOURNAL OF APPLIED PHYSICS, 2009, 105 (12)
  • [5] X-ray spectroscopy and dosimetry with a portable CdTe device
    Abbene, Leonardo
    La Manna, Angelo
    Fauci, Francesco
    Gerardi, Gaetano
    Stumbo, Simone
    Raso, Giuseppe
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) : 373 - 377
  • [6] GAMMA RESPONSE OF SEMI-INSULATING MATERIAL IN PRESENCE OF TRAPPING AND DETRAPPING
    AKUTAGAWA, W
    ZANIO, K
    [J]. JOURNAL OF APPLIED PHYSICS, 1969, 40 (09) : 3838 - +
  • [7] [Anonymous], 2003, N4231 IEEE ANSI, P1
  • [8] Twin shaping filter techniques to compensate the signals from CZT/CdTe detectors
    Auricchio, N
    Amati, L
    Basili, A
    Caroli, E
    Donati, A
    Franceschini, T
    Frontera, F
    Landini, G
    Roggio, A
    Schiavone, F
    Stephen, JB
    Ventura, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1982 - 1988
  • [9] Digital pulse-shape processing for CdTe detectors
    Bargholtz, C
    Fumero, E
    Mårtensson, L
    Wachtmeister, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) : 290 - 292
  • [10] CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS
    BARRETT, HH
    ESKIN, JD
    BARBER, HB
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (01) : 156 - 159