Safety and efficacy of using 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures

被引:8
作者
Chen, Michael J. [1 ]
DeBaun, Malcolm R. [1 ]
Salazar, Brett P. [1 ]
Lai, Cara [1 ]
Bishop, Julius A. [1 ]
Gardner, Michael J. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Med Ctr, 450 Broadway St,Pavil C,4th Floor, Stanford, CA 94063 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2020年 / 51卷 / 03期
关键词
Clavicle fracture; Dual plating; Symptomatic implants; Implant removal;
D O I
10.1016/j.injury.2020.01.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The purpose of this study was to evaluate the safety and efficacy of using lower profile 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate constructs for fixation of diaphyseal clavicle fractures. Methods: This was a retrospective case series of all displaced diaphyseal clavicle fractures treated with 2.4/2.4 and 2.0/2.4 dual mini-fragment plate constructs at a single level-one trauma center. Postoperative complications and fracture healing rates were recorded. A subset of patients with long-term follow up was used to determine the rate of reoperation for symptomatic implant removal. Results: All 36 identified fractures healed without loss of reduction or implant failure. There was one superficial infection and no deep infections or cases of wound dehiscence. Twenty patients from the entire cohort had longer-term follow up available to assess the reoperation rate for symptomatic implant removal. Two patients (10%) underwent symptomatic implant removal, and one patient with retained implants was planning on future removal due to soft-tissue irritation; this combined to a projected reoperation rate of 15% for symptomatic implant removal. Conclusion: Dual mini-fragment plating of diaphyseal clavicle fractures, using 2.4/2.4 mm and 2.0/2.4 mm plate combinations, creates a lower profile construct that reliably maintains fracture reduction to healing, and has a low rate of reoperation for symptomatic implant removal. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:647 / 650
页数:4
相关论文
共 11 条
  • [1] Surgical Treatment of Displaced Midshaft Clavicle Fractures: Precontoured Plates Versus Noncontoured Plates
    Ao Rongguang
    Jian Zhen
    Zhou Jianhua
    Shi Jifei
    Jiang Xinhua
    Yu Baoqing
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (09): : E263 - E266
  • [2] Are commercially-available precontoured anatomical clavicle plating systems offering the purported superior optimum fitting to the clavicle? A cadaveric analysis and review of literature
    Bauer, D. E.
    Hingsammer, A.
    Schenk, P.
    Vlachopoulos, L.
    Imam, M. A.
    Fuernstahl, P.
    Meyer, D. C.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (06) : 755 - 758
  • [3] Czajka Cory M, 2017, J Orthop Trauma, V31, P236, DOI 10.1097/BOT.0000000000000760
  • [4] Clavicular anatomy and the applicability of precontoured plates
    Huang, Jerry I.
    Toogood, Paul
    Chen, Michael R.
    Wilber, John H.
    Cooperman, Daniel R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10) : 2260 - 2265
  • [5] Anteroinferior versus superior plating of clavicular fractures
    Hulsmans, Martijn H. J.
    van Heijl, Mark
    Houwert, R. Marijn
    Timmers, Tim K.
    van Olden, Ger
    Verleisdonk, Egbert Jan M. M.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (03) : 448 - 454
  • [6] Rate of and Risk Factors for Reoperations After Open Reduction and Internal Fixation Midshaft Clavicle Fractures A Population-Based Study in Ontario, Canada
    Leroux, Timothy
    Wasserstein, David
    Henry, Patrick
    Khoshbin, Amir
    Dwyer, Tim
    Ogilvie-Harris, Darrell
    Mahomed, Nizar
    Veillette, Christian
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (13) : 1119 - 1125
  • [7] How well do contoured superior midshaft clavicle plates fit the clavicle? A cadaveric study
    Malhas, Amar M.
    Skarparis, Yiannis G.
    Sripada, Sankar
    Soames, Roger W.
    Jariwala, Arpit C.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 954 - 959
  • [8] Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation
    Prasarn, Mark L.
    Meyers, Kathleen N.
    Wilkin, Geoffrey
    Wellman, David S.
    Chan, Daniel B.
    Ahn, Jaimo
    Lorich, Dean G.
    Helfet, David L.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (12) : 1655 - 1662
  • [9] Plate fixation compared with nonoperative treatment of displaced midshaft clavicular fractures: a randomized clinical trial
    Qvist, A. H.
    Vaesel, M. T.
    Jensen, C. M.
    Jensen, S. L.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (10) : 1385 - 1391
  • [10] Precontoured Plating of Clavicle Fractures: Decreased Hardware-related Complications?
    VanBeek, Corinne
    Boselli, Karen J.
    Cadet, Edwin R.
    Ahmad, Christopher S.
    Levine, William N.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) : 3337 - 3343