Transient deflection response in microcantilever array integrated with polydimethylsiloxane (PDMS) microfluidics

被引:21
作者
Anderson, Ryan R. [1 ]
Hu, Weisheng [1 ]
Noh, Jong Wook [1 ]
Dahlquist, William C. [1 ]
Ness, Stanley J. [1 ]
Gustafson, Timothy M. [1 ]
Richards, Danny C. [1 ]
Kim, Seunghyun [1 ]
Mazzeo, Brian A. [1 ]
Woolley, Adam T. [2 ]
Nordin, Gregory P. [1 ]
机构
[1] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
BOVINE SERUM-ALBUMIN; PHOTONIC TRANSDUCTION; BIOLOGICAL SENSORS; READ-OUT; BIOSENSORS; DIFFUSION; SURFACES; PLATFORM; STICK;
D O I
10.1039/c1lc20025a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the integration of a nanomechanical sensor consisting of 16 silicon microcantilevers with polydimethylsiloxane (PDMS) microfluidics. For microcantilevers positioned near the bottom of a microfluidic flow channel, a transient differential analyte concentration for the top versus bottom surface of each microcantilever is created when an analyte-bearing fluid is introduced into the flow channel (which is initially filled with a non-analyte containing solution). We use this effect to characterize a bare (nonfunctionalized) microcantilever array in which the microcantilevers are simultaneously read out with our recently developed high sensitivity in-plane photonic transduction method. We first examine the case of non-specific binding of bovine serum albumin (BSA) to silicon. The average maximum transient microcantilever deflection in the array is -1.6 nm, which corresponds to a differential surface stress of only -0.23 mN m(-1). This is in excellent agreement with the maximum differential surface stress calculated based on a modified rate equation in conjunction with finite element simulation. Following BSA adsorption, buffer solutions with different pH are introduced to further study microcantilever array transient response. Deflections of 20-100 nm are observed (2-14 mN m(-1) differential surface stress). At a flow rate of 5 mu L min(-1), the average measured temporal width (FWHM) of the transient response is 5.3 s for BSA non-specific binding and 0.74 s for pH changes.
引用
收藏
页码:2088 / 2096
页数:9
相关论文
共 41 条
[1]   Nanowatt chemical vapor detection with a self-sensing, piezoelectric microcantilever array [J].
Adams, JD ;
Parrott, G ;
Bauer, C ;
Sant, T ;
Manning, L ;
Jones, M ;
Rogers, B ;
McCorkle, D ;
Ferrell, TL .
APPLIED PHYSICS LETTERS, 2003, 83 (16) :3428-3430
[2]   CYTOPLASMIC HYDROGEN-ION DIFFUSION-COEFFICIENT [J].
ALBALDAWI, NF ;
ABERCROMBIE, RF .
BIOPHYSICAL JOURNAL, 1992, 61 (06) :1470-1479
[3]   Microcantilever-based platforms as biosensing tools [J].
Alvarez, Mar ;
Lechuga, Laura M. .
ANALYST, 2010, 135 (05) :827-836
[4]   A label-free immunosensor array using single-chain antibody fragments [J].
Backmann, N ;
Zahnd, C ;
Huber, F ;
Bietsch, A ;
Plückthun, A ;
Lang, HP ;
Güntherodt, HJ ;
Hegner, M ;
Gerber, C .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (41) :14587-14592
[5]   Nanomechanical detection of DNA melting on microcantilever surfaces [J].
Biswal, Sibani Lisa ;
Raorane, Digvijay ;
Chaiken, Alison ;
Birecki, Henryk ;
Majumdar, Arun .
ANALYTICAL CHEMISTRY, 2006, 78 (20) :7104-7109
[6]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[7]   Processing of kinetic microarray signals [J].
Braun, Thomas ;
Huber, Francois ;
Ghatkesar, Murali Krishna ;
Backmann, Natalija ;
Lang, Hans Peter ;
Gerber, Christoph ;
Hegner, Martin .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 128 (01) :75-82
[8]   A sensitive method to measure changes in the surface stress of solids [J].
Butt, HJ .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 180 (01) :251-260
[9]   Highly sensitive polymer-based cantilever-sensors for DNA detection [J].
Calleja, M ;
Nordström, M ;
Alvarez, M ;
Tamayo, J ;
Lechuga, LM ;
Boisen, A .
ULTRAMICROSCOPY, 2005, 105 (1-4) :215-222
[10]  
DAHLQUIST WC, 2010, J MICRONANOLIT UNPUB