Transient deflection response in microcantilever array integrated with polydimethylsiloxane (PDMS) microfluidics

被引:21
作者
Anderson, Ryan R. [1 ]
Hu, Weisheng [1 ]
Noh, Jong Wook [1 ]
Dahlquist, William C. [1 ]
Ness, Stanley J. [1 ]
Gustafson, Timothy M. [1 ]
Richards, Danny C. [1 ]
Kim, Seunghyun [1 ]
Mazzeo, Brian A. [1 ]
Woolley, Adam T. [2 ]
Nordin, Gregory P. [1 ]
机构
[1] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
BOVINE SERUM-ALBUMIN; PHOTONIC TRANSDUCTION; BIOLOGICAL SENSORS; READ-OUT; BIOSENSORS; DIFFUSION; SURFACES; PLATFORM; STICK;
D O I
10.1039/c1lc20025a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the integration of a nanomechanical sensor consisting of 16 silicon microcantilevers with polydimethylsiloxane (PDMS) microfluidics. For microcantilevers positioned near the bottom of a microfluidic flow channel, a transient differential analyte concentration for the top versus bottom surface of each microcantilever is created when an analyte-bearing fluid is introduced into the flow channel (which is initially filled with a non-analyte containing solution). We use this effect to characterize a bare (nonfunctionalized) microcantilever array in which the microcantilevers are simultaneously read out with our recently developed high sensitivity in-plane photonic transduction method. We first examine the case of non-specific binding of bovine serum albumin (BSA) to silicon. The average maximum transient microcantilever deflection in the array is -1.6 nm, which corresponds to a differential surface stress of only -0.23 mN m(-1). This is in excellent agreement with the maximum differential surface stress calculated based on a modified rate equation in conjunction with finite element simulation. Following BSA adsorption, buffer solutions with different pH are introduced to further study microcantilever array transient response. Deflections of 20-100 nm are observed (2-14 mN m(-1) differential surface stress). At a flow rate of 5 mu L min(-1), the average measured temporal width (FWHM) of the transient response is 5.3 s for BSA non-specific binding and 0.74 s for pH changes.
引用
收藏
页码:2088 / 2096
页数:9
相关论文
共 41 条
  • [1] Nanowatt chemical vapor detection with a self-sensing, piezoelectric microcantilever array
    Adams, JD
    Parrott, G
    Bauer, C
    Sant, T
    Manning, L
    Jones, M
    Rogers, B
    McCorkle, D
    Ferrell, TL
    [J]. APPLIED PHYSICS LETTERS, 2003, 83 (16) : 3428 - 3430
  • [2] CYTOPLASMIC HYDROGEN-ION DIFFUSION-COEFFICIENT
    ALBALDAWI, NF
    ABERCROMBIE, RF
    [J]. BIOPHYSICAL JOURNAL, 1992, 61 (06) : 1470 - 1479
  • [3] Microcantilever-based platforms as biosensing tools
    Alvarez, Mar
    Lechuga, Laura M.
    [J]. ANALYST, 2010, 135 (05) : 827 - 836
  • [4] A label-free immunosensor array using single-chain antibody fragments
    Backmann, N
    Zahnd, C
    Huber, F
    Bietsch, A
    Plückthun, A
    Lang, HP
    Güntherodt, HJ
    Hegner, M
    Gerber, C
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (41) : 14587 - 14592
  • [5] Nanomechanical detection of DNA melting on microcantilever surfaces
    Biswal, Sibani Lisa
    Raorane, Digvijay
    Chaiken, Alison
    Birecki, Henryk
    Majumdar, Arun
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (20) : 7104 - 7109
  • [6] Environmental sensors based on micromachined cantilevers with integrated read-out
    Boisen, A
    Thaysen, J
    Jensenius, H
    Hansen, O
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 11 - 16
  • [7] Processing of kinetic microarray signals
    Braun, Thomas
    Huber, Francois
    Ghatkesar, Murali Krishna
    Backmann, Natalija
    Lang, Hans Peter
    Gerber, Christoph
    Hegner, Martin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 128 (01) : 75 - 82
  • [8] A sensitive method to measure changes in the surface stress of solids
    Butt, HJ
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 180 (01) : 251 - 260
  • [9] Highly sensitive polymer-based cantilever-sensors for DNA detection
    Calleja, M
    Nordström, M
    Alvarez, M
    Tamayo, J
    Lechuga, LM
    Boisen, A
    [J]. ULTRAMICROSCOPY, 2005, 105 (1-4) : 215 - 222
  • [10] DAHLQUIST WC, 2010, J MICRONANOLIT UNPUB