共 5 条
A Combination Bismuth Bulk Electrode and Its Use in Adsorptive Constant-Current Stripping Chronopotentiometry for Iron Using Solochrome Violet RS
被引:3
|作者:
Pimrote, Wachirawan
[2
,3
]
Ratana-Ohpas, Roongroje
[3
]
Renman, Lars
[1
]
机构:
[1] Karlstad Univ, Dept Chem & Biomed Sci, SE-65188 Karlstad, Sweden
[2] Naresuan Univ, Dept Chem, Phayao 56000, Thailand
[3] Walailak Univ, Dept Chem, Nakhon Si Thammarat 80161, Thailand
关键词:
Bismuth bulk electrode;
Adsorptive constant-current stripping chronopotentiometry;
Iron;
Solochrome Violet RS;
Partial least squares calibration;
LEAST-SQUARES REGRESSION;
FILM ELECTRODE;
VOLTAMMETRY;
POTENTIOMETRY;
COMPLEXES;
ELECTROANALYSIS;
CALIBRATION;
IRON(III);
NICKEL;
SYSTEM;
D O I:
10.1002/elan.201100013
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
A new combination bismuth bulk electrode allowing potentiostatic control to be maintained in a suspended sample drop is described. The electrode was tested by adsorptive constant-current stripping chronopotentiometry for iron( III) using Solochrome Violet RS. Optimum conditions were similar to those established with mercury-based electrodes. With an electropolishing scheme, a reproducibility better than 2% (n = 54) was attainable. The limit of detection was 0.6 mu g L(-1) in deoxygenated samples. A partial least squares calibration gave a result of 972 +/- 78 mu g L(-1) (95%, n = 5) for a 1000 +/- 5 mu g L(-1) iron reference solution.
引用
收藏
页码:1607 / 1614
页数:8
相关论文