Experimental investigation of heat and moisture transfer performance of CaCl2/H2O-SiO2 nanofluid in a gas-liquid microporous hollow fiber membrane contactor

被引:34
作者
Zheng, Yuanzhou [1 ,2 ]
Yang, Haoran [1 ,2 ]
Fazilati, Mohammad Ali [3 ]
Toghraie, Davood [3 ]
Rahimi, Hossein [3 ]
Afrand, Masoud [4 ,5 ]
机构
[1] Wuhan Univ Technol, Hubei Key Lab Inland Shipping Technol, 588 Youyi Ave, Wuhan, Peoples R China
[2] Wuhan Univ Technol, Sch Nav, 588 Youyi Ave, Wuhan, Peoples R China
[3] Islamic Azad Univ, Dept Mech Engn, Khomeinishahr Branch, Khomeinishahr, Iran
[4] Ton Duc Thang Univ, Adv Inst Mat Sci, Lab Magnetism & Magnet Mat, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
基金
中国国家自然科学基金;
关键词
Hollow fiber membrane; Air dehumidification; Aqueous solution of calcium chloride; SiO2; nanoparticles; AIR-CONDITIONING SYSTEM; MASS-TRANSFER; THERMAL-CONDUCTIVITY; HYBRID NANOFLUID; CO2; ABSORPTION; DEHUMIDIFICATION PERFORMANCE; REGENERATION PERFORMANCE; RHEOLOGICAL BEHAVIOR; NATURAL-CONVECTION; LICL SOLUTION;
D O I
10.1016/j.icheatmasstransfer.2020.104533
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, aqueous solution of CaCl2/SiO2 nanoparticles has been used as a desiccant in a gas-liquid hollow fiber membrane (HFM) air dehumidifier contactor system. The heat and mass (H/M) transfer properties HFM energy exchanger with CaCl2/H2O-SiO2 as desiccant solution studied experimentally for first time. Effects of different parameters on H/M transfer characteristics of system, including the nanoparticle concentration, liquid flow rate and liquid temperature were examined experimentally. The experiments arranged for desiccant temperatures of 20 degrees C and 26 degrees C, desiccant solutions of 0, 1%wt and 2%wt concentration and flow rates of 1.1, 1.25, 1.4 and 1.7 ml/s. The results indicated that the influence of particles on moisture removal rate is the greatest for the conditions of highest solution temperature and the highest particle. By introducing nanofluid solution as liquid desiccant in system the enhancing effect of reducing desiccant temperature on moisture removal lessens and declined to zero by increasing the solution flow rate with a high descending rate. For 2%wt nanoparticle concentration by 53% increase of absorbent flow rate, the value of temperature effectiveness reduced by 30%. This justifies adiabatic application of hollow fiber membrane systems with nanofluid desiccant.
引用
收藏
页数:14
相关论文
共 40 条
  • [1] State-of-the-art in liquid desiccant air conditioning equipment and systems
    Abdel-Salam, Ahmed H.
    Simonson, Carey J.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 58 : 1152 - 1183
  • [2] Experimental investigation of rheological behavior of the hybrid nanofluid of MWCNT-alumina/water (80%)-ethylene-glycol (20%)
    Afshari, Ashkan
    Akbari, Mohammad
    Toghraie, Davood
    Yazdi, Mohammad Eftekhari
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2018, 132 (02) : 1001 - 1015
  • [3] An experimental study on the stability and thermal conductivity of water-ethylene glycol/TiO2-MWCNTs hybrid nanofluid: Developing a new correlation
    Akhgar, Alireza
    Toghraie, Davood
    [J]. POWDER TECHNOLOGY, 2018, 338 : 806 - 818
  • [4] Mass transfer in nanofluids: A review
    Ashrafmansouri, Seyedeh-Saba
    Esfahany, Mohsen Nasr
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 82 : 84 - 99
  • [5] State-of-art in modelling methods of membrane-based liquid desiccant heat and mass exchanger: A comprehensive review
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Chu, Junze
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 : 445 - 470
  • [6] Coleman H.W., 2010, Noise Control Eng. J, V58, P343, DOI DOI 10.3397/1.3383084
  • [7] Experimental study on dehumidification performance enhancement by TiO2 superhydrophilic coating for liquid desiccant plate dehumidifiers
    Dong, Chuanshuai
    Lu, Lin
    Wen, Tao
    [J]. BUILDING AND ENVIRONMENT, 2017, 124 : 219 - 231
  • [8] Evaluation of the removal of CO2 using membrane contactors: Membrane wettability
    El-Naas, Muftah H.
    Al-Marzouqi, Mohamed
    Marzouk, Sayed A.
    Abdullatif, Nadia
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2010, 350 (1-2) : 410 - 416
  • [9] A new correlation for predicting the thermal conductivity of ZnO-Ag (50%-50%)/water hybrid nanofluid: An experimental study
    Esfahani, Navid Nasajpour
    Toghraie, Davood
    Afrand, Masoud
    [J]. POWDER TECHNOLOGY, 2018, 323 : 367 - 373
  • [10] Natural convection liquid desiccant loop as an auxiliary air conditioning system: investigating the operational parameters
    Fazilati, Mohammad Ali
    Alemrajabi, Ali Akbar
    Sedaghat, Ahmad
    [J]. HEAT AND MASS TRANSFER, 2018, 54 (03) : 903 - 913