Hybrid total knee arthroplasty

被引:21
作者
Faris, Philip M. [1 ]
Keating, E. Michael [1 ]
Farris, Alex [1 ]
Meding, John B. [1 ]
Ritter, Merrill A. [1 ]
机构
[1] St Francis Hosp, Ctr Hip & Knee Surg, Mooresville, IN 46158 USA
关键词
D O I
10.1007/s11999-008-0195-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A retrospective study of 201 anatomic graduated component total knee arthroplasties implanted with hybrid fixation at the authors' center was performed in response to conflicting data in the literature concerning the benefits of a hybrid method. Selection for hybrid fixation was nonrandomized and based on femoral component fit. Survivorship analysis was performed, and rates of radiolucent lines surrounding the femoral component and occurrence of osteolysis were noted. At 7 and 13 years, survivorship with tibial or femoral revision as the end point was 0.9926 and 0.9732, respectively. Radiolucencies were found adjacent to 15 femoral components at final followup (seven in Zone 1, three in Zone 2, five in Zone 3, one in Zone 4, two in Zone 5, zero in Zone 6). Osteolysis was observed in one knee after secondary evaluation. Hybrid fixation in a selected patient population can result in excellent results in middle to long-term followup. Level of Evidence: Level IV, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:1204 / 1209
页数:6
相关论文
共 58 条
[1]   Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement [J].
Arora, J ;
Ogden, AC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (11) :1502-1506
[2]   WHAT PRICE PROGRESS - FAILED INNOVATIONS OF THE KNEE PROSTHESIS [J].
BAUER, GCH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :245-246
[3]  
BERRY DJ, 1993, CLIN ORTHOP RELAT R, P204
[4]   Implant survivorship and complication rates after total knee arthroplasty with a third-generation cemented system [J].
Bozic, KJ ;
Kinder, J ;
Menegini, M ;
Zurakowski, D ;
Rosenberg, AG ;
Galante, JO .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) :117-124
[5]   DESIGNER HIPS [J].
BULSTRODE, CJK ;
MURRAY, DW ;
CARR, AJ ;
PYNSENT, PB ;
CARTER, SR .
BRITISH MEDICAL JOURNAL, 1993, 306 (6880) :732-733
[6]  
Campbell MD, 1998, CLIN ORTHOP RELAT R, P58
[7]   Cemented tibial component fixation performs better than cementless fixation -: A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years [J].
Carlsson, Å ;
Björkman, A ;
Besjakov, J ;
Önsten, I .
ACTA ORTHOPAEDICA, 2005, 76 (03) :362-369
[8]  
Collier J P, 1991, Instr Course Lect, V40, P89
[9]   Osteolysis after total knee arthroplasty: Influence of tibial baseplate surface finish and sterilization of polyethylene insert - Findings at five to ten years postoperatively [J].
Collier, MB ;
Engh, CA ;
McAuley, JP ;
Ginn, SD ;
Engh, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (12) :2702-2708
[10]   Backside wear of polyethylene tibial inserts: Mechanism and magnitude of material loss [J].
Conditt, MA ;
Thompson, MT ;
Usrey, MM ;
Ismaily, SK ;
Noble, PC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (02) :326-331