Fast high-resolution T1 mapping of the human brain

被引:78
|
作者
Deichmann, R [1 ]
机构
[1] Inst Neurol, Wellcome Dept Imaging Neurosci, London WC1N 3BG, England
基金
英国惠康基金;
关键词
T-1; mapping; quantitative brain imaging; relaxometry; quantification; high resolution;
D O I
10.1002/mrm.20552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A sequence for the acquisition of high-resolution T, maps, based on magnetization-prepared multislice fast low-angle shot (FLASH) imaging, is presented. In contrast to similar methods, no saturation pulses are used, resulting in an increased dynamic range of the relaxation process. Furthermore, it is possible to acquire data during all relaxation delays because only slice-selective radiofrequency (RF) pulses are used for inversion and excitation. This allows for a reduction of the total acquisition time, or scanning with a reduced bandwidth, which improves the signal-to-noise ratio (SNR). The method generates quantitative T-1 maps with an in-plane resolution of 1 mm, slice thickness of 4 mm, and whole-brain coverage in a clinically acceptable imaging time of about 19s per slice. It is shown that the use of off-center RF pulses does not result in imperfect inversion or magnetization transfer (MT) effects. In addition, an improved fitting algorithm based on smoothed flip angle maps is presented and tested successfully. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [41] High-resolution mapping of human glioma genomes
    Bredel, M
    Bredel, C
    Juric, D
    Harsh, GR
    Vogel, H
    Recht, LD
    Sikic, BI
    NEUROSURGERY, 2005, 57 (02) : 427 - 428
  • [42] Rapid high-resolution volumetric T1 mapping using a highly accelerated stack-of-stars Look Locker technique
    Li, Zhitao
    Fu, Zhiyang
    Keerthivasan, Mahesh
    Bilgin, Ali
    Johnson, Kevin
    Galons, Jean-Philippe
    Vedantham, Srinivasan
    Martin, Diego R.
    Altbach, Maria, I
    MAGNETIC RESONANCE IMAGING, 2021, 79 : 28 - 37
  • [43] Simultaneous high-resolution cardiac T1 mapping and cine imaging using model-based iterative image reconstruction
    Becker, Kirsten M.
    Schulz-Menger, Jeanette
    Schaeffter, Tobias
    Kolbitsch, Christoph
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1080 - 1091
  • [44] Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    Cheng, HLM
    Wright, GA
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 566 - 574
  • [45] FAST INVERSION RECOVERY T1 CONTRAST AND CHEMICAL-SHIFT CONTRAST IN HIGH-RESOLUTION SNAPSHOT FLASH MR IMAGES
    MATTHAEI, D
    HAASE, A
    HENRICH, D
    DUHMKE, E
    MAGNETIC RESONANCE IMAGING, 1992, 10 (01) : 1 - 6
  • [46] USE OF HIGH-RESOLUTION CYTOMETRY IN PREDICTING THE BIOLOGIC BEHAVIOR OF T1 ADENOCARCINOMA OF THE LUNG
    IKEDA, N
    MACAULAY, C
    LAM, S
    GARNER, DM
    PAYNE, PW
    KATO, H
    KONAKA, C
    PALCIC, B
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1995, 17 (01): : 69 - 74
  • [47] High-resolution temporal and regional mapping of MAPT expression and splicing in human brain development
    Hefti, Marco M.
    Farrell, Kurt
    Kim, SoongHo
    Bowles, Kathryn R.
    Fowkes, Mary E.
    Raj, Towfique
    Crary, John F.
    PLOS ONE, 2018, 13 (04):
  • [48] Human myocardium: Single-breath-hold MR T1 mapping with high spatial resolution - Reproducibility study
    Messroghli, DR
    Plein, S
    Higgins, DM
    Walters, K
    Jones, TR
    Ridgway, JP
    Sivananthan, MU
    RADIOLOGY, 2006, 238 (03) : 1004 - 1012
  • [49] Fast T1 mapping on a whole-body scanner
    Deichmann, R
    Hahn, D
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 206 - 209
  • [50] Performance Comparison of Compressed Sensing Algorithms for Accelerating T1ρ Mapping of Human Brain
    Menon, Rajiv G.
    Zibetti, Marcelo V. W.
    Jain, Rajan
    Ge, Yulin
    Regatte, Ravinder R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1130 - 1139