Electron beam inactivation of Tulane virus on fresh produce, and mechanism of inactivation of human norovirus surrogates by electron beam irradiation

被引:32
作者
Predmore, Ashley [1 ]
Sanglay, Gabriel C. [1 ]
DiCaprio, Erin [2 ]
Li, Jianrong [2 ]
Uribe, R. M. [3 ]
Lee, Ken [1 ]
机构
[1] Ohio State Univ, Coll Food Agr & Environm Sci, Dept Food Sci & Technol, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Vet Med, Dept Vet Biosci, Columbus, OH 43210 USA
[3] Kent State Univ, Coll Technol, Kent, OH 44242 USA
关键词
Electron beam; Irradiation; Norovirus; Virus; Produce; E-beam; MURINE NOROVIRUS; FOODBORNE VIRUSES; NORWALK VIRUS; COLI O157H7; TEXTURE; QUALITY; CALICIVIRUS; LETTUCE; STORAGE;
D O I
10.1016/j.ijfoodmicro.2014.12.024
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Ionizing radiation, whether by electron beams or gamma rays, is a non-thermal processing technique used to improve the microbial safety and shelf-life of many different food products. This technology is highly effective against bacterial pathogens, but data on its effect against foodborne viruses is limited. A mechanism of viral inactivation has been proposed with gamma irradiation, but no published study discloses a mechanism for electron beam (e-beam). This study had three distinct goals: 1) evaluate the sensitivity of a human norovirus surrogate, Tulane virus (TV), to e-beam irradiation in foods, 2) compare the difference in sensitivity of TV and murine norovirus (MNV-1) to e-beam irradiation, and 3) determine the mechanism of inactivation of these two viruses by e-beam irradiation. TV was reduced from 7 log10 units to undetectable levels at target doses of 16 kGy or higher in two food matrices (strawberries and lettuce). MNV-1 was more resistant to e-beam treatment than TV. At target doses of 4 kGy, e-beam provided a 1.6 and 1.2 log reduction of MNV-1 in phosphate buffered saline (PBS) and Dulbecco's Modified Eagle Medium (DMEM), compared to a 1.5 and 1.8 log reduction of TV in PBS and Opti-MEM, respectively. Transmission electron microscopy revealed that increased e-beam doses negatively affected the structure of both viruses. Analysis of viral proteins by SDS-PAGE found that irradiation also degraded viral proteins. Using RT-PCR, irradiation was shown to degrade viral genomic RNA. This suggests that the mechanism of inactivation of e-beam was likely the same as gamma irradiation as the damage to viral constituents led to inactivation. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 48 条
  • [1] Effect of oxygen and carbon dioxide absorbers on strawberry quality
    Aday, Mehmet Seckin
    Caner, Cengiz
    Rahvali, Fatih
    [J]. POSTHARVEST BIOLOGY AND TECHNOLOGY, 2011, 62 (02) : 179 - 187
  • [2] Norwalk virus shedding after experimental human infection
    Atmar, Robert L.
    Opekun, Antone R.
    Gilger, Mark A.
    Estes, Mary K.
    Crawford, Sue E.
    Neill, Frederick H.
    Graham, David Y.
    [J]. EMERGING INFECTIOUS DISEASES, 2008, 14 (10) : 1553 - 1557
  • [3] Determination of the 50% Human Infectious Dose for Norwalk Virus
    Atmar, Robert L.
    Opekun, Antone R.
    Gilger, Mark A.
    Estes, Mary K.
    Crawford, Sue E.
    Neill, Frederick H.
    Ramani, Sasirekha
    Hill, Heather
    Ferreira, Jennifer
    Graham, David Y.
    [J]. JOURNAL OF INFECTIOUS DISEASES, 2014, 209 (07) : 1016 - 1022
  • [4] Barbosa-Canovas GV, 1998, FOOD IRRADIATION NON, P161
  • [5] Foodborne viral gastroenteritis: Challenges and opportunities
    Bresee, JS
    Widdowson, MA
    Monroe, SS
    Glass, RI
    [J]. CLINICAL INFECTIOUS DISEASES, 2002, 35 (06) : 748 - 753
  • [6] Centers for Disease Control and Prevention, 2009, NOR Q A
  • [7] Dickson J.S., 2001, FOOD IRRADIATION PRI, P23
  • [8] Diehl J.F., 1995, Safety of Irradiated Foods, V2nd, P9
  • [9] Diehl J.F., 1999, Safety of Irradiated Foods, DOI DOI 10.1016/j.foodres.2014.06.022
  • [10] Characterization of a rhesus monkey calicivirus representing a new genus of Calicivitidae
    Farkas, Tibor
    Sestak, Karol
    Wei, Chao
    Jiang, Xi
    [J]. JOURNAL OF VIROLOGY, 2008, 82 (11) : 5408 - 5416