Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty

被引:6
|
作者
Gosens, T
van Langelaan, EJ
机构
[1] St Elizabeth Hosp, NL-5022 GC Tilburg, Netherlands
[2] Rijnland Hosp, NL-2353 GA Leiderdorp, Netherlands
关键词
D O I
10.1007/s00264-005-0659-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We used a proximally hydroxyapatite-coated femoral stem in revision arthroplasty of 48 cases with aseptic loosening and Paprosky defect class 1 or 2. We reviewed the outcome after 6.1 (4-9.3) years. The clinical outcome was good, with a mean postoperative HHS of 90 (51-100) points. There were five reoperations all on the acetabular side and none for the femoral stem. At follow-up, we observed cancellous sclerosis radiographically in 19 cases-especially in non-tightly fitted stems and mainly in Gruen zones 2 and 6. In 13 cases, cortical thickening was seen, mainly in Gruen zones 3 and 5 and especially in tightly fitted stems. These bony changes were significant and not related to any clinical parameter. They started to appear from 6 months onward, with increasing frequency with longer follow-up. We find that the standard Mallory-Head hydroxyapatite-coated femoral stem is suitable for revision in cases with lower-class femoral defects.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 50 条
  • [1] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    T. Gosens
    E. J. van Langelaan
    International Orthopaedics, 2005, 29 : 219 - 223
  • [2] Survivorship and Radiological Analysis of a Monoblock, Hydroxyapatite-Coated Titanium Stem in Revision Hip Arthroplasty
    Saunders, Paul R. J.
    Shaw, Debbie A.
    Sidharthan, Sijin K.
    Siney, Paul D.
    Young, Stephen K.
    Board, Tim N.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : 1678 - 1685
  • [3] Extensively hydroxyapatite-coated long femoral stem revision hip arthroplasty: Clinical outcome and survivorship in 11 to 17.5 years follow up
    Hong, Liu Wing
    Yin, Chung Kwong
    Wing, Cheung Kin
    Hing, Chiu Kwok
    Kevin, Ho Ki Wai
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2022, 29 (02)
  • [4] The use of a hydroxyapatite-coated primary stem in revision total hip arthroplasty
    Kelly, SJ
    Incavo, SJ
    Beynnon, B
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01): : 64 - 71
  • [5] The effect of intramedullary bone plug on femoral stem migration of hydroxyapatite-coated hip arthroplasty
    Kligman, M
    Roffman, M
    ORTHOPEDICS, 2000, 23 (07) : 681 - 685
  • [6] Femoral revision using long hydroxyapatite-coated interlocking stem
    Malhotra, R.
    Dua, Aman
    Kiran, E. Krishna
    Bhan, S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) : 355 - 362
  • [7] Hip offset and leg-length restoration in revision hip arthroplasty with a monoblock, hydroxyapatite-coated stem
    Saunders, Paul
    Shaw, Debbie
    Sidharthan, Sijin
    Young, Stephen K.
    Board, Tim
    HIP INTERNATIONAL, 2023, 33 (05) : 880 - 888
  • [8] Femoral revision using long hydroxyapatite-coated interlocking stem
    R. Malhotra
    Aman Dua
    E. Krishna Kiran
    S. Bhan
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 355 - 362
  • [9] Femoral component revision using an extensively hydroxyapatite-coated stem
    Crawford, CH
    Malkani, AL
    Incavo, SJ
    Morris, HB
    Krupp, RJ
    Baker, D
    JOURNAL OF ARTHROPLASTY, 2004, 19 (01): : 8 - 13
  • [10] RADIOGRAPHIC PATTERNS IN TOTAL HIP-ARTHROPLASTY - HYDROXYAPATITE-COATED AND UNCOATED FEMORAL STEM PROSTHESES
    FOX, MG
    RAK, KM
    LISECKI, EJ
    CASTELLO, PH
    RADIOLOGY, 1995, 197 : 396 - 396