A novel high-throughput assay for the measurement of salivary progesterone by liquid chromatography tandem mass spectrometry

被引:9
|
作者
Schiffer, Lina [1 ,2 ]
Adaway, Joanne E. [3 ]
Baranowski, Elizabeth S. [1 ,2 ]
Arlt, Wiebke [1 ,2 ]
Keevil, Brian G. [3 ]
机构
[1] Univ Birmingham, Inst Metab & Syst Res, Birmingham, W Midlands, England
[2] Birmingham Hlth Partners, Ctr Endocrinol Diabet & Metab, Birmingham, W Midlands, England
[3] Manchester Univ NHS Trust, Manchester Acad Hlth Sci Ctr, Wythenshawe Hosp, Biochem Dept, Manchester, Lancs, England
基金
英国医学研究理事会;
关键词
Progesterone; saliva; liquid chromatography tandem mass spectrometry; DIRECT RADIOIMMUNOASSAY; ENZYME-IMMUNOASSAY; COLLECTION DEVICES; STEROID-HORMONES; PRETERM BIRTH; PLASMA; PHASE; WOMEN; VALIDATION; ADULT;
D O I
10.1177/0004563218780904
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Liquid chromatography tandem mass spectrometry (LC-MS/MS) enables specific and sensitive quantification of steroids with a high throughput. Saliva sampling is advantageous for multisample profiling over longer periods of time, as it is non-invasive, cheap, can be carried out at home and does not require the attendance of clinical personnel. We developed a rapid LC-MS/MS for the measurement of salivary progesterone, frequently assessed as ovulation marker in patients desiring fertility. Methods Samples (300 mu L) were prepared by supported liquid extraction using dichloromethane and were reconstituted in 40% methanol. Chromatography was performed using a C8 column with a water/methanol gradient containing 0.1% formic acid and 2 mmol/L ammonium acetate. Quantification was performed with a Waters TQ-S mass spectrometer. Results Total run time was 5.5 min. The lower limit of quantification was 20 pmol/L (1.2 fmol on column). Inter- and intra-assay comparison showed coefficients of variation and bias between measured and nominal concentrations of less than 11%. Mean recovery was 91%. Interference with a large set of natural and synthetic steroids was excluded. The assay was successfully applied to measure progesterone variation during the menstrual cycle (n = 9) and diurnal variations during luteal phase (n = 7) in regularly cycling women. Discussion We present a novel LC-MS/MS assay for the determination of salivary progesterone with high-throughput potential. The applicability of the assay for progesterone profiling during the menstrual cycle is demonstrated.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [41] A fully validated high-throughput liquid chromatography tandem mass spectrometry method for automatic extraction and quantitative determination of endogenous nutritional biomarkers in dried blood spot samples
    Lin, Yun
    Chen, Jie-Hua
    He, Ruikun
    Tang, Bingxuan
    Jiang, Limiao
    Zhang, Xuguang
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1622
  • [42] Liquid chromatography-tandem mass spectrometry measurement of 26 steroid hormones in human serum and plasma samples
    Jia, Yongjuan
    Liu, Xingli
    Xu, Li
    Zhao, Jinbao
    Ni, Junjun
    Zhang, Yuanyuan
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (12) : 2358 - 2370
  • [43] Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry
    Matysik, Silke
    Liebisch, Gerhard
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1526 : 112 - 118
  • [44] Development of a high-throughput ultra performance liquid chromatography-mass spectrometry assay to profile 18 eicosanoids as exploratory biomarkers for atherosclerotic diseases
    Rago, Brian
    Fu, Cexiong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 936 : 25 - 32
  • [45] A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays
    Sangoi, Maximiliano da Silva
    Wrasse, Micheli
    D'Avila, Felipe Bianchini
    Bernardi, Raquel Martini
    de Oliveira, Paulo Renato
    Dalmora, Sergio Luiz
    Bueno Rolim, Clarice Madalena
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (06) : 723 - 730
  • [46] Quantitative high-throughput analysis of 16 (Fluoro)quinolones in honey using automated extraction by turbulent flow chromatography coupled to liquid chromatography-tandem mass Spectrometry
    Mottier, Pascal
    Hammel, Yves-Alexis
    Gremaud, Eric
    Guy, Philippe A.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (01) : 35 - 43
  • [47] Measurement of steroid hormones by liquid chromatography-tandem mass spectrometry with small amounts of hair
    Hobo, Yoshitaka
    Nishikawa, Jun
    Miyashiro, Yoshimichi
    Fujikata, Akira
    STEROIDS, 2020, 164
  • [48] High-throughput screening of salivary polyamine markers for discrimination of colorectal cancer by multisegment injection capillary electrophoresis tandem mass spectrometry
    Igarashi, Kaori
    Ota, Sana
    Kaneko, Miku
    Hirayama, Akiyoshi
    Enomoto, Masanobu
    Katumata, Kenji
    Sugimoto, Masahiro
    Soga, Tomoyoshi
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1652
  • [49] Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay for the quantification of Dexamphetamine in human plasma
    Herbrink, M.
    Thijssen, B.
    Hillebrand, M. J. X.
    Rosing, H.
    Schellens, J. H. M.
    Nuijen, B.
    Beijnen, J. H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 148 : 259 - 264
  • [50] Is calibration the cause of variation in liquid chromatography tandem mass spectrometry testosterone measurement?
    Owen, L. J.
    MacDonald, P. R.
    Keevil, B. G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2013, 50 (04) : 368 - 370