QRS Fragmentation Is Not Associated with Poor Response to Cardiac Resynchronization Therapy

被引:19
|
作者
Rickard, John [1 ]
Zardkoohi, Omeed [1 ]
Popovic, Zoran [1 ]
Verhaert, David [1 ]
Sraow, Dan [1 ]
Baranowski, Bryan [1 ]
Martin, David O. [1 ]
Grimm, Richard A. [1 ]
Chung, Mina K. [1 ]
Tchou, Patrick [1 ]
Lindsay, Bruce A. [1 ]
Wilkoff, Bruce L. [1 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Inst Heart & Vasc, Cleveland, OH 44195 USA
关键词
cardiac resynchronization therapy; electrocardiogram; ECG; QRS fragmentation; left ventricular scar; 12-LEAD ECG; Q-WAVE; MARKER; SCAR; PREDICTOR; COMPLEXES; MORTALITY; EVENTS;
D O I
10.1111/j.1542-474X.2011.00424.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: We reviewed the preimplant and follow-up echocardiograms in 233 patients undergoing the new implantation of a CRT device between December 2001 and November 2006. Patients were included if they had a pre-CRT ECG with appropriate filter settings (filter 0.16-100 or 0.16-150 Hz, 25 mm/s, 10 mm/mV), a left ventricular ejection fraction (LVEF) < 40%, and New York Heart Association class II-IV symptoms on standard medical therapy. The 12-lead electrocardiogram (ECG) was interpreted by two blinded reviewers for the presence of fQRS. Remodeling end points, including changes in LVEF and left ventricular end-diastolic (LVEDV) and systolic (LVESV) volumes, were compared between patients with and without contiguous fQRS, and an assessment of all-cause mortality was made. Results: Two hundred thirty-two patients met inclusion criteria, of which 50 demonstrated fQRS in contiguous leads. There was no difference in improvement in LVEF (%) (7.9 +/- 12.9 vs 6.8 +/- 11.0, P = 0.60) or reduction in LVEDV (mL) (-30.1 +/- 57.2 vs -15.7 +/- 47.6) or LVESV (mL) (-33.7 +/- 58.1 vs -22.7 +/- 50.6, P = 0.40) between patients with and without contiguous fQRS. At a mean follow-up of 4.4 +/- 1.9 years, there were a total of 89 deaths, 22 (44.0%) in patients with contiguous fQRS and 67 (36.8%) without (log rank P = 0.31). Conclusions: QRS fragmentation is not a predictor of progressive ventricular remodeling or mortality in heart failure patients undergoing CRT. Ann Noninvasive Electrocardiol 2011;16(2):165-171.
引用
收藏
页码:165 / 171
页数:7
相关论文
共 50 条
  • [31] Notched QRS Complex in Lateral Leads as a Novel Predictor of Response to Cardiac Resynchronization Therapy
    Pan, Wenzhi
    Su, Yangang
    Zhu, Wenqin
    Shu, Xianhong
    Ge, Junbo
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2013, 18 (02) : 181 - 187
  • [32] Usefulness of notched duration to predict response to cardiac resynchronization therapy
    Balci, Mustafa Mucahit
    Balci, Kevser Gulcihan
    Sen, Fatih
    Maden, Orhan
    Unal, Sefa
    Selcuk, Mehmet Timur
    Selcuk, Hatice
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2015, 49 (04) : 200 - 206
  • [33] Impaired Renal Function Is Associated With Echocardiographic Nonresponse and Poor Prognosis After Cardiac Resynchronization Therapy
    Van Bommel, Rutger J.
    Mollema, Sjoerd A.
    Borleffs, Jan Willem
    Bertini, Matteo
    Ypenburg, Claudia
    Marsan, Nina Ajmone
    Delgado, Victoria
    Van Der Wall, Ernst E.
    Schalij, Martin J.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) : 549 - 555
  • [34] Ventricular arrhythmia risk is associated with myocardial scar but not with response to cardiac resynchronization therapy
    Linhart, Markus
    Doltra, Adelina
    Acosta, Juan
    Borras, Roger
    Jauregui, Beatriz
    Fernandez-Armenta, Juan
    Anguera, Ignasi
    Bisbal, Felipe
    Marti-Almor, Julio
    Tolosana, Jose M.
    Penela, Diego
    Soto-Iglesias, David
    Villuendas, Roger
    Perea, Rosario J.
    Ortiz, Jose T.
    Bosch, Xavier
    Auricchio, Angelo
    Mont, Lluis
    Berruezo, Antonio
    EUROPACE, 2020, 22 (09): : 1391 - 1400
  • [35] Characteristics of heart failure patients associated with good and poor response to cardiac resynchronization therapy: a PROSPECT (Predictors of Response to CRT) sub-analysis
    van Bommel, Rutger J.
    Bax, Jeroen J.
    Abraham, William T.
    Chung, Eugene S.
    Pires, Luis A.
    Tavazzi, Luigi
    Zimetbaum, Peter J.
    Gerritse, Bart
    Kristiansen, Nina
    Ghio, Stefano
    EUROPEAN HEART JOURNAL, 2009, 30 (20) : 2470 - 2477
  • [36] Precision of automated QRS duration measurement in patients treated with cardiac resynchronization therapy
    Lund-Andersen, Casper
    Petersen, Helen H.
    Jons, Christian
    Philbert, Berit T.
    Tfelt-Hansen, Jacob
    Skovgaard, Lene T.
    Svendsen, Jesper H.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 52 (01) : 103 - 110
  • [37] QRS prolongation after cardiac resynchronization therapy is a predictor of persistent mechanical dyssynchrony
    Karaca, Oguz
    Omaygenc, Onur
    Cakal, Beytullah
    Cakal, Sinem Deniz
    Barutcu, Irfan
    Boztosun, Bilal
    Kilicaslan, Fethi
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 46 (02) : 105 - 113
  • [38] Precision of automated QRS duration measurement in patients treated with cardiac resynchronization therapy
    Casper Lund-Andersen
    Helen H. Petersen
    Christian Jøns
    Berit T. Philbert
    Jacob Tfelt-Hansen
    Lene T. Skovgaard
    Jesper H. Svendsen
    Journal of Interventional Cardiac Electrophysiology, 2018, 52 : 103 - 110
  • [39] Biomarkers to predict the response to cardiac resynchronization therapy
    Heggermont, Ward
    Auricchio, Angelo
    Vanderheyden, Marc
    EUROPACE, 2019, 21 (11): : 1609 - 1620
  • [40] Cardiac resynchronization therapy in patients with narrow QRS: what benefits?
    Vincenti, Antonio
    GIORNALE ITALIANO DI CARDIOLOGIA, 2012, 13 (10) : 157S - 159S