Bearing capacity of spread footings on aggregate pier-reinforced clay: updates and stress concentration

被引:12
作者
Bong, Taeho [1 ]
Stuedlein, Armin W. [2 ]
Martin, John [2 ]
Kim, Byoung-Il [3 ]
机构
[1] Seoul Natl Univ, Inst Construct & Environm Engn, Seoul 08826, South Korea
[2] Oregon State Univ, 101 Kearney Hall, Corvallis, OR 97331 USA
[3] Myongji Univ, Yongin 17058, Gyeonggi Do, South Korea
基金
加拿大自然科学与工程研究理事会;
关键词
ground improvement; aggregate pier; load tests; bearing capacity; stress concentration ratio; RELIABILITY-BASED DESIGN; PILES;
D O I
10.1139/cgj-2019-0026
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Aggregate piers represent an economical ground improvement technique used to increase bearing capacity and reduce settlements of weak soils. Several approaches have been developed to estimate the bearing capacity of aggregate pier-reinforced clay, but these models exhibit large prediction bias and uncertainty. This study uses newly developed footing loading test data to investigate the relationship between the bearing capacity and the area replacement and slenderness ratios. The bearing capacity of a single aggregate pier, whether isolated or in groups, below a loaded footing increases as the area replacement ratio decreases due to increase in extent of confined soil surrounding the pier. The length and diameter of an aggregate pier is also shown to result in significantly increased bearing capacity, an effect that diminishes with increasing slenderness. New modifications are proposed to existing simplified and cavity expansion models to account for the effect of confinement, area replacement ratio, and slenderness ratio using a leave-one-out cross-validation technique. The cross-validation analysis resulted in robust bearing capacity models that are more accurate than existing analytical models. Additionally, the stress concentration ratio for shallow foundations supported by aggregate pier-reinforced plastic soils at failure was estimated and compared with the available data, indicating its sensitivity to design variables and showing that this critical design parameter may be predicted using the updated models.
引用
收藏
页码:717 / 727
页数:11
相关论文
共 30 条
[11]  
Duncan J.M., 2007, DENSITIES FRICTION A
[12]  
Giancristofaro R. A., 2003, STATISTICA, V63, P375
[13]  
Hughes J.M.O., 1974, P I CIVIL ENG GROUND, V5, P42, DOI [10.1016/0148-9062(74)90643-3.Crossref,GoogleScholar, DOI 10.1016/0148-9062(74)90643-3]
[14]   FIELD TRIAL OF REINFORCING EFFECT OF A STONE COLUMN IN SOIL [J].
HUGHES, JMO ;
WITHERS, NJ ;
GREENWOOD, DA .
GEOTECHNIQUE, 1975, 25 (01) :31-44
[15]   Bayesian Updating of Bearing Capacity Models for Individual Stone Columns [J].
Jimenez, Rafael ;
Feng, Xianda ;
Alonso-Pollan, Jose A. .
JOURNAL OF COMPUTING IN CIVIL ENGINEERING, 2017, 31 (05)
[16]  
Kahiel A, 2017, GEORISK, V11, P75, DOI 10.1080/17499518.2016.1221980
[17]  
Lu N., 2004, UNSATURATED SOIL MEC
[18]   STRIP FOOTING ON WEAK CLAY STABILIZED WITH A GRANULAR TRENCH OR PILE [J].
MADHAV, MR ;
VITKAR, PP .
CANADIAN GEOTECHNICAL JOURNAL, 1978, 15 (04) :605-609
[19]  
Martin J., 2018, THESIS
[20]  
Meyerhof G.G., 1965, J SOIL MECH FDN DIVI, V91, P21, DOI [10.1061/JSFEAQ.000071, DOI 10.1061/JSFEAQ.0000719]