Technological quality requirements for stereotactic radiotherapy Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy

被引:106
作者
Schmitt, Daniela [1 ]
Blanck, Oliver [2 ]
Gauer, Tobias [3 ]
Fix, Michael K. [4 ,5 ]
Brunner, Thomas B. [6 ]
Fleckenstein, Jens [7 ]
Loutfi-Krauss, Britta [8 ]
Manser, Peter [4 ,5 ]
Werner, Rene [9 ]
Wilhelm, Maria-Lisa [10 ]
Baus, Wolfgang W. [11 ]
Moustakis, Christos [12 ]
机构
[1] Univ Klinikum Heidelberg, Heidelberger Inst Radioonkol HIRO, Natl Ctr Radiat Res Oncol NCRO, Klin Radioonkol & Strahlentherapie, Heidelberg, Germany
[2] Univ Klinikum Schleswig Holstein, Klin Strahlentherapie, Kiel, Germany
[3] Univ Klinikum Hamburg Eppendorf, Klin Strahlentherapie & Radioonkol, Hamburg, Germany
[4] Univ Bern, Abt Med Strahlenphys, Inselspital, Univ Spital Bern, Bern, Switzerland
[5] Univ Bern, Univ Radioonkol, Inselspital, Univ Spital Bern, Bern, Switzerland
[6] Univ Magdeburg, Univ Klin Strahlentherapie, Magdeburg, Germany
[7] Heidelberg Univ, Univ Med Mannheim, Klin Strahlentherapie & Radioonkol, Mannheim, Germany
[8] Univ Klinikum Frankfurt, Klin Strahlentherapie & Onkol, Frankfurt, Germany
[9] Univ Klinikum Hamburg Eppendorf, Inst Computat Neurosci, Hamburg, Germany
[10] Univ Med Rostock, Klin Strahlentherapie, Rostock, Germany
[11] Univ Klinikum Koln, Klin Radioonkol, CyberKnife & Strahlentherapie, Cologne, Germany
[12] Univ Klinikum Munster, Klin Strahlentherapie Radioonkol, Munster, Germany
关键词
Radiosurgery; Recommendations; Technique; SRS; FSRT; SBRT; BODY RADIATION-THERAPY; CONE-BEAM CT; DOSE CALCULATION ALGORITHMS; GUIDED CRANIAL RADIOSURGERY; ULTRASOUND IMAGE GUIDANCE; TARGET VOLUME DEFINITION; LUNG-CANCER PATIENTS; TIME TUMOR-TRACKING; MONTE-CARLO; GAMMA-KNIFE;
D O I
10.1007/s00066-020-01583-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
引用
收藏
页码:421 / 443
页数:23
相关论文
共 220 条
[1]   Dosimetric analysis of Tomotherapy-based intracranial stereotactic radiosurgery of brain metastasis [J].
Agostinelli, S. ;
Garelli, S. ;
Gusinu, M. ;
Zeverino, M. ;
Cavagnetto, F. ;
Pupillo, F. ;
Bellini, A. ;
Taccini, G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 :48-55
[2]   Evaluation of potential internal target volume of liver tumors using [J].
Akino, Yuichi ;
Oh, Ryoong-Jin ;
Masai, Norihisa ;
Shiomi, Hiroya ;
Inoue, Toshihiko .
MEDICAL PHYSICS, 2014, 41 (11)
[3]   Evaluation of stability of stereotactic space defined by cone-beam CT for the Leksell Gamma Knife Icon [J].
AlDahlawi, Ismail ;
Prasad, Dheerendra ;
Podgorsak, Matthew B. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03) :67-72
[4]   Dosimetric effect of multileaf collimator leaf width on volumetric modulated arc stereotactic radiotherapy for spine tumors [J].
Amoush, Ahmad ;
Long, Huang ;
Subedi, Laxmi ;
Qi, Peng ;
Djemil, Toufik ;
Xia, Ping .
MEDICAL DOSIMETRY, 2017, 42 (02) :111-115
[5]  
[Anonymous], 2016, ACC REQ UNC RAD THER
[6]  
[Anonymous], 2018, 68098 DIN
[7]   To frame or not to frame? Cone-beam CT-based analysis of head immobilization devices specific to linac-based stereotactic radiosurgery and radiotherapy [J].
Babic, Steven ;
Lee, Young ;
Ruschin, Mark ;
Lochray, Fiona ;
Lightstone, Alex ;
Atenafu, Eshetu ;
Phan, Nic ;
Mainprize, Todd ;
Tsao, May ;
Soliman, Hany ;
Sahgal, Arjun .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02) :111-120
[8]  
Badakhshi H, 2013, ANTICANCER RES, V33, P4639
[9]   4D-CT imaging with synchronized intravenous contrast injection to improve delineation of liver tumors for treatment planning [J].
Beddar, A. Sam ;
Briere, Tina Marie ;
Batter, Peter ;
Pan, Tinsu ;
Totani, Naresh ;
Ng, Chaan ;
Szklaruk, Janio ;
Krishnan, Sunil .
RADIOTHERAPY AND ONCOLOGY, 2008, 87 (03) :445-448
[10]   Plan delivery quality assurance for CyberKnife: Statistical process control analysis of 350 film-based patient-specific QAs [J].
Bellec, J. ;
Delaby, N. ;
Jouyaux, F. ;
Perdrieux, M. ;
Bouvier, J. ;
Sorel, S. ;
Henry, O. ;
Lafond, C. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 :50-58