The effect of laryngeal mask airway insertion on the position of the internal jugular vein

被引:26
作者
Nandwani, N
Fairfield, MC
Krarup, K
Thompson, J
机构
[1] University Dept. of Anaesthesia, Leicester Royal Infirmary
关键词
equipment; airway; laryngeal mask; veins; jugular; cannulation;
D O I
10.1111/j.1365-2044.1997.012-az012.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A high-quality ultrasound system (Dyasonics Prisma) was used to study the effect of laryngeal mask airway insertion and cuff inflation on the position and relations of the internal jugular vein in eight healthy young patients undergoing elective surgery. On insertion of the laryngeal mask, with the cuff pre-inflated with 10 mi of air, some minor movement was discernible in the larynx. Neither the larynx nor surrounding structures changed significantly in position. However, on full inflation of the laryngeal mask cuff there was a more noticeable movement of the larynx, which visibly distended in an anterior direction. The mean anterior displacement was 0.8 cm (range 0.6-1.1 cm). There was no significant lateral displacement of the carotid artery or internal jugular vein and there was no significant compression of these structures. We conclude that in the presence of a laryngeal mask airway fixed landmarks such as the sternal notch and angle of the jaw should be used to identify the likely position of the internal jugular vein. Difficulty in cannulation may be experienced lithe mobile laryngeal structures are used as landmarks.
引用
收藏
页码:77 / 79
页数:3
相关论文
共 8 条