Numerical analysis of axially loaded circular high strength concrete-filled double steel tubular short columns

被引:80
作者
Ahmed, Mizan [1 ]
Liang, Qing Quan [1 ]
Patel, Vipulkumar Ishvarbhai [2 ]
Hadi, Muhammad N. S. [3 ]
机构
[1] Victoria Univ, Coll Engn & Sci, POB 14428, Melbourne, Vic 8001, Australia
[2] La Trobe Univ, Sch Engn & Math Sci, Bendigo, Vic 3552, Australia
[3] Univ Wollongong, Sch Civil Min & Environm Engn, Wollongong, NSW 2522, Australia
关键词
Concrete-filled double steel tubes; Composite columns; High-strength concrete; Numerical modeling; PERFORMANCE-BASED ANALYSIS; STRESS-STRAIN MODEL; NONLINEAR-ANALYSIS; STUB COLUMNS; BEAM-COLUMNS; BEHAVIOR; RANGE; DESIGN; TUBES;
D O I
10.1016/j.tws.2019.02.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Circular high-strength concrete-filled double steel tubular (CFDST) columns are high performance members where the internal and external steel tubes offer significant confinement to the concrete infill. The confinement remarkably improves the concrete compressive strength and ductility. However, no fiber element models have been formulated for computing the responses of CFDST columns with circular steel tubes filled with high strength concrete incorporating accurate confinement to the core and sandwiched concrete. In this paper, a new fiber-based numerical model is developed that computes the axial load-strain responses of circular high-strength CFDST short columns under axial loading. Based on existing experimental results, a new confining pressure model is developed for the determination of the confining pressures on the core-concrete in CFDST columns with circular sections. A new strength degradation parameter is also proposed that allows the concrete post-peak characteristics to be quantified. The fiber-based numerical model validated by experimental data is used to assess the responses of high-strength CFDST columns considering important parameters, which include the inner steel tube, external tube diameter-to-thickness ratio and concrete and steel strengths. A simple expression is derived for the estimation of the axial load-carrying capacities of circular short CFDST columns and comparisons with several design codes are made. The proposed fiber-based analysis technique and design equation can accurately determine the responses of short circular high-strength CFDST columns.
引用
收藏
页码:105 / 116
页数:12
相关论文
共 43 条
[1]   Nonlinear analysis of rectangular concrete-filled double steel tubular short columns incorporating local buckling [J].
Ahmed, Mizan ;
Liang, Qing Quan ;
Patel, Vipulkumar Ishvarbhai ;
Hadi, Muhammad N. S. .
ENGINEERING STRUCTURES, 2018, 175 :13-26
[2]  
American Concrete Institute, 2011, ACI 318-11
[3]  
[Anonymous], 2016, AISC 360 16
[4]  
[Anonymous], 1983, THESIS
[5]   Study on concrete-filled stainless steel carbon steel tubular (CFSCT) stub columns under compression [J].
Chang, Xu ;
Ru, Zhong Liang ;
Zhou, Wei ;
Zhang, Yong-Bin .
THIN-WALLED STRUCTURES, 2013, 63 :125-133
[6]   STRAIN OF CONCRETE AT PEAK COMPRESSIVE STRESS FOR A WIDE-RANGE OF COMPRESSIVE STRENGTHS [J].
DENICOLO, B ;
PANI, L ;
POZZO, E .
MATERIALS AND STRUCTURES, 1994, 27 (168) :206-210
[7]   Concrete filled double circular steel tube (CFDCST) stub columns [J].
Ekmekyapar, Talha ;
Al-Eliwi, Baraa J. M. .
ENGINEERING STRUCTURES, 2017, 135 :68-80
[8]   Behaviour of normal and high strength concrete-filled compact steel tube circular stub columns [J].
Ellobody, Ehab ;
Young, Ben ;
Lam, Dennis .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (07) :706-715
[9]  
European Committee for Standardization, 2004, DES COMP STEEL CONCR
[10]   Axial capacity of circular concrete-filled tube columns [J].
Giakoumelis, G ;
Lam, D .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (07) :1049-1068