Interaction Between Electric and Acoustic Stimulation Influences Speech Perception in Ipsilateral EAS Users

被引:24
作者
Imsiecke, Marina [1 ]
Krueger, Benjamin [1 ,2 ]
Buechner, Andreas [1 ,2 ]
Lenarz, Thomas [1 ,2 ]
Nogueira, Waldo [1 ,2 ]
机构
[1] Hannover Med Sch, Dept Otorhinolaryngol, Hannover, Germany
[2] Cluster Excellence Hearing4all, Hannover, Germany
关键词
Cochlear implant; Electric-acoustic stimulation; Fitting strategy; Ipsilateral masking; Residual hearing; Speech reception; COCHLEAR IMPLANT USERS; LOW-FREQUENCY HEARING; AUDITORY-SYSTEM; ELECTROACOUSTIC STIMULATION; SPIRAL GANGLION; INSERTION DEPTH; HAIR-CELLS; PRESERVATION; NOISE; BENEFITS;
D O I
10.1097/AUD.0000000000000807
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: The aim of this study was to determine electric-acoustic masking in cochlear implant users with ipsilateral residual hearing and different electrode insertion depths and to investigate the influence on speech reception. The effects of different fitting strategies-meet, overlap, and a newly developed masking adjusted fitting (UNMASKfit)-on speech reception are compared. If electric-acoustic masking has a detrimental effect on speech reception, the individualized UNMASKfit map might be able to reduce masking and thereby enhance speech reception. Design: Fifteen experienced MED-EL Flex electrode recipients with ipsilateral residual hearing participated in a crosssover design study using three fitting strategies for 4 weeks each. The following strategies were compared: (1) a meet fitting, dividing the frequency range between electric and acoustic stimulation, (2) an overlap fitting, delivering part of the frequency range both acoustically and electrically, and (3) the UNMASKfit, reducing the electric stimulation according to the individual electric-on-acoustic masking strength. A psychoacoustic masking procedure was used to measure the changes in acoustic thresholds due to the presence of electric maskers. Speech reception was measured in noise with the Oldenburg Matrix Sentence test. Results: Behavioral thresholds of acoustic probe tones were significantly elevated in the presence of electric maskers. A maximum of masking was observed when the difference in location between the electric and acoustic stimulation was around one octave in place frequency. Speech reception scores and strength of masking showed a dependency on residual hearing, and speech reception was significantly reduced in the overlap fitting strategy. Electric- acoustic stimulation significantly improved speech reception over electric stimulation alone, with a tendency toward a larger benefit with the UNMASKfit map. In addition, masking was significantly inversely correlated to the speech reception performance difference between the overlap and the meet fitting. Conclusions: (1) This study confirmed the interaction between ipsilateral electric and acoustic stimulation in a psychoacoustic masking experiment. (2) The overlap fitting yielded poorer speech reception performance in stationary noise especially in subjects with strong masking. (3) The newly developed UNMASKfit strategy yielded similar speech reception thresholds with an enhanced acoustic benefit, while at the same time reducing the electric stimulation. This could be beneficial in the long-term if applied as a standard fitting, as hair cells are exposed to less possibly adverse electric stimulation. In this study, the UNMASKfit allowed the participants a better use of their natural hearing even after 1 month of adaptation. It might be feasible to transfer these results to the clinic, by fitting patients with the UNMASKfit upon their first fitting appointment, so that longer adaptation times can further improve speech reception.
引用
收藏
页码:868 / 882
页数:15
相关论文
共 73 条
[1]   Impact of electrode insertion depth on intracochlear trauma [J].
Adunka, Oliver ;
Kiefer, Jan .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2006, 135 (03) :374-382
[2]   Speech and music perception with the new fine structure speech coding strategy: preliminary results [J].
Arnoldner, Christoph ;
Riss, Dominik ;
Brunner, Markus ;
Durisin, Martin ;
Baumgartner, Wolf-Dieter ;
Hamzavi, Jafar-Sasan .
ACTA OTO-LARYNGOLOGICA, 2007, 127 (12) :1298-1303
[3]   Cochlear implant channel separation and its influence on speech perception - Implications for a new electrode design [J].
Arnoldner, Christoph ;
Riss, Dominik ;
Baumgartner, Wolf-Dieter ;
Kaider, Alexandra ;
Hamzavi, Jafar-Sasan .
AUDIOLOGY AND NEURO-OTOLOGY, 2007, 12 (05) :313-324
[4]   The Effect of Different Cochlear Implant Microphones on Acoustic Hearing Individuals' Binaural Benefits for Speech Perception in Noise [J].
Aronoff, Justin M. ;
Freed, Daniel J. ;
Fisher, Laurel M. ;
Pal, Ivan ;
Soli, Sigfrid D. .
EAR AND HEARING, 2011, 32 (04) :468-484
[5]  
Baumgarte F, 1997, 103RD AES CONVENTION, V4511
[6]  
Buchman CA, 2014, OTOL NEUROTOL, V35, P1773, DOI 10.1097/MAO.0000000000000541
[7]   Impact of Low-Frequency Hearing [J].
Buechner, A. ;
Schuessler, M. ;
Battmer, R. D. ;
Stoever, T. ;
Lesinski-Schiedat, A. ;
Lenarz, T. .
AUDIOLOGY AND NEURO-OTOLOGY, 2009, 14 :8-13
[8]   Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis [J].
Buechner, Andreas ;
Illg, Angelika ;
Majdani, Omid ;
Lenarz, Thomas .
PLOS ONE, 2017, 12 (05)
[9]  
Buechner Andreas, 2011, Cochlear Implants Int, V12, P194, DOI 10.1179/1754762811Y0000000009
[10]   Does cochlear implantation and electrical stimulation affect residual hair cells and spiral ganglion neurons? [J].
Coco, Anne ;
Epp, Stephanie B. ;
Fallon, James B. ;
Xu, Jin ;
Millard, Rodney E. ;
Shepherd, Robert K. .
HEARING RESEARCH, 2007, 225 (1-2) :60-70