Non-Contrast Renal Magnetic Resonance Imaging to Assess Perfusion and Corticomedullary Differentiation in Health and Chronic Kidney Disease

被引:52
|
作者
Gillis, Keith A. [1 ]
McComb, Christie [1 ]
Patel, Rajan K. [1 ]
Stevens, Kathryn K. [1 ]
Schneider, Markus P. [4 ]
Radjenovic, Aleksandra [1 ]
Morris, Scott T. W. [2 ]
Roditi, Giles H. [3 ]
Delles, Christian [1 ]
Mark, Patrick B. [1 ]
机构
[1] Univ Glasgow, Inst Cardiovasc & Med Sci, 126 Univ Pl, Glasgow G12 8TA, Lanark, Scotland
[2] Queen Elizabeth Univ Hosp, Glasgow Renal & Transplant Unit, Glasgow, Lanark, Scotland
[3] Glasgow Royal Infirm, Dept Radiol, Glasgow, Lanark, Scotland
[4] Univ Erlangen Nurnberg, Dept Hypertens & Nephrol, Erlangen, Germany
关键词
Magnetic resonance imaging; Arterial spin labeling; Renal perfusion; Chronic kidney disease; SPIN-LABELING MRI; TRANSPLANTED KIDNEYS; INITIAL-EXPERIENCE; FLOW; ASL; REPRODUCIBILITY; QUANTIFICATION; VOLUNTEERS;
D O I
10.1159/000447601
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims: Arterial spin labelling (ASL) MRI measures perfusion without administration of contrast agent. While ASL has been validated in animals and healthy volunteers (HVs), application to chronic kidney disease (CKD) has been limited. We investigated the utility of ASL MRI in patients with CKD. Methods: We studied renal perfusion in 24 HVs and 17 patients with CKD (age 22-77 years, 40% male) using ASL MRI at 3.0T. Kidney function was determined using estimated glomerular filtration rate (eGFR). T1 relaxation time was measured using modified look-locker inversion and flow-sensitive alternating inversion recovery true-fast imaging and steady precession was performed to measure cortical and whole kidney perfusion. Results: T1 was higher in CKD within cortex and whole kidney, and there was association between T1 time and eGFR. No association was seen between kidney size and volume and either T1, or ASL perfusion. Perfusion was lower in CKD in cortex (136 +/- 37 vs. 279 +/- 69 ml/min/100 g; p < 0.001) and whole kidney (146 +/- 24 vs. 221 +/- 38 ml/min/100 g; p < 0.001). There was significant, negative, association between T1 longitudinal relaxation time and ASL perfusion in both the cortex (r = -0.75, p < 0.001) and whole kidney (r = -0.50, p < 0.001). There was correlation between eGFR and both cortical (r = 0.73, p < 0.01) and whole kidney (r = 0.69, p < 0.01) perfusion. Conclusions: Significant differences in renal structure and function were demonstrated using ASL MRI. T1 may be representative of structural changes associated with CKD; however, further investigation is required into the pathological correlates of reduced ASL perfusion and increased T1 time in CKD. (C) 2016 S. Karger AG, Basel
引用
收藏
页码:183 / 192
页数:10
相关论文
共 50 条
  • [31] Rapid non-contrast magnetic resonance imaging for post appendectomy intra-abdominal abscess in children
    Lee, Megan H.
    Eutsler, Eric P.
    Sheybani, Elizabeth F.
    Khanna, Geetika
    PEDIATRIC RADIOLOGY, 2017, 47 (08) : 935 - 941
  • [32] Non-contrast magnetic resonance imaging for guiding left ventricular lead position in cardiac resynchronization therapy
    Mads Brix Kronborg
    Won Yong Kim
    Peter Thomas Mortensen
    Jens Cosedis Nielsen
    Journal of Interventional Cardiac Electrophysiology, 2012, 33 : 27 - 35
  • [33] Glenohumeral Articular Cartilage Lesions: Prospective Comparison of Non-Contrast Magnetic Resonance Imaging and Findings at Arthroscopy
    Spencer, Brian A.
    Dolinskas, Carol A.
    Seymour, Peter A.
    Thomas, Stephen J.
    Abboud, Joseph A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (09): : 1466 - 1470
  • [34] Evaluation of Renal Tissue Oxygenation Using Blood Oxygen Level-Dependent Magnetic Resonance Imaging in Chronic Kidney Disease
    Chen, Fen
    Yan, Han
    Yang, Fan
    Cheng, Li
    Zhang, Siwei
    Li, Shulin
    Liu, Caixia
    Xu, Kai
    Sun, Dong
    KIDNEY & BLOOD PRESSURE RESEARCH, 2021, 46 (04): : 441 - 451
  • [35] Quantitative assessment of renal structural and functional changes in chronic kidney disease using multi-parametric magnetic resonance imaging
    Buchanan, Charlotte E.
    Mahmoud, Huda
    Cox, Eleanor F.
    McCulloch, Thomas
    Prestwich, Benjamin L.
    Taal, Maarten W.
    Selby, Nicholas M.
    Francis, Susan T.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 (06) : 955 - 964
  • [36] Diffusion-weighted imaging versus non-contrast magnetic resonance imaging in the diagnosis of acute appendicitis during pregnancy
    Kulali, Fatma
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2023, 69 (01): : 56 - 60
  • [37] Best non-contrast magnetic resonance imaging sequence and role of intravenous contrast administration in evaluation of perianal fistula with surgical correlation
    Das, Gaurav Chayan
    Chakrabartty, Deba Kumar
    ABDOMINAL RADIOLOGY, 2021, 46 (02) : 469 - 475
  • [38] Best non-contrast magnetic resonance imaging sequence and role of intravenous contrast administration in evaluation of perianal fistula with surgical correlation
    Gaurav Chayan Das
    Deba Kumar Chakrabartty
    Abdominal Radiology, 2021, 46 : 469 - 475
  • [39] Magnetic Resonance Imaging-Derived Microvascular Perfusion Modeling to Assess Peripheral Artery Disease
    Gimnich, Olga A.
    Belousova, Tatiana
    Short, Christina M.
    Taylor, Addison A.
    Nambi, Vijay
    Morrisett, Joel D.
    Ballantyne, Christie M.
    Bismuth, Jean
    Shah, Dipan J.
    Brunner, Gerd
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (03):
  • [40] Non-contrast Magnetic Resonance Imaging for Diagnosis and Monitoring of Vestibular Schwannomas: A Systematic Review and Meta-analysis
    Kim, Do Hyun
    Lee, Seoungmin
    Hwang, Se Hwan
    OTOLOGY & NEUROTOLOGY, 2019, 40 (09) : 1126 - 1133