Actuator and sensor placement for closed-loop control of convective instabilities

被引:5
|
作者
Freire, Guilherme A. [1 ]
Cavalieri, Andre V. G. [1 ]
Silvestre, Flavio J. [1 ]
Hanifi, A. [2 ]
Henningson, D. S. [2 ]
机构
[1] Inst Tecnol Aeronaut ITA, Div Aeronaut Engn, Sao Jose Dos Campos, Brazil
[2] KTH Royal Inst Technol, Linne FLOW Ctr, S-10044 Stockholm, Sweden
关键词
Convective instabilities; Closed-loop control; Sensor-actuator placement; MODEL-REDUCTION; GLOBAL INSTABILITIES; FLOW; STABILITY;
D O I
10.1007/s00162-020-00537-9
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This work deals with the characterization of the closed-loop control performance aiming at the delay of transition. We focus on convective wavepackets, typical of the initial stages of transition to turbulence, starting with the linearized Kuramoto-Sivashinsky equation as a model problem representative of the transitional 2D boundary layer; its simplified structure and reduced order provide a manageable framework for the study of fundamental concepts involving the control of linear wavepackets. The characterization is then extended to the 2D Blasius boundary layer. The objective of this study is to explore how the sensor-actuator placement affects the optimal control problem, formulated using linear quadratic Gaussian (LQG) regulators. This is carried out by evaluating errors of the optimal estimator at positions where control gains are significant, through a proposed metric, labelled as gamma. Results show, in quantitative manner, why some choices of sensor-actuator placement are more effective than others for flow control: good (respectively, bad) closed-loop performance is obtained when estimation errors are low (respectively, high) in the regions with significant gains in the full-state-feedback problem. Unsatisfactory performance is further understood as dominant estimation error modes that overlap spatially with control gains, which shows directions for improvement of a given set-up by moving sensors or actuators. The proposed metric and analysis explain most trends in closed-loop performance as a function of sensor and actuator position, obtained for the model problem and for the 2D Blasius boundary layer. The spatial characterization of the gamma-metric provides thus a valuable and intuitive tool for the problem of sensor-actuator placement, targeting here transition delay but possibly extending to other amplifier-type flows.
引用
收藏
页码:619 / 641
页数:23
相关论文
共 50 条
  • [31] A self-sensing soft pneumatic actuator with closed-Loop control for haptic feedback wearable devices
    Yu, Meng
    Cheng, Xiang
    Peng, Shigang
    Cao, Yingze
    Lu, Yamei
    Li, Bingyang
    Feng, Xiangchao
    Zhang, Yan
    Wang, Haoyu
    Jiao, Zhiwei
    Wang, Pengfei
    Zhao, Liangyu
    MATERIALS & DESIGN, 2022, 223
  • [32] DEVELOPMENT OF FLEXIBLE FABRIC BASED TACTILE SENSOR FOR CLOSED LOOP CONTROL OF SOFT ROBOTIC ACTUATOR
    Ponraj, Godwin
    Kirthika, Senthil Kumar
    Thakor, Nitish V.
    Yeow, Chen-Hua
    Kukreja, Sunil L.
    Ren, Hongliang
    2017 13TH IEEE CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING (CASE), 2017, : 1451 - 1456
  • [33] Comparisons between Quantum Open-Loop Control and Closed-Loop Control
    Bo, Qi
    Lei, Guo
    PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 7, 2008, : 393 - 397
  • [34] OPEN-LOOP VERSUS CLOSED-LOOP CONTROL OF PROCESSOR LOADING
    SCHOUTE, FC
    PERFORMANCE EVALUATION, 1990, 11 (03) : 201 - 208
  • [35] Closed-loop control of power system transient stability(5): calculation of control quantity
    Zhang, Baohui, 1600, Electric Power Automation Equipment Press (34): : 1 - 5
  • [36] Closed-loop based detection of debonding of piezoelectric actuator patches in controlled beams
    Sun, DC
    Tong, LY
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2003, 40 (10) : 2449 - 2471
  • [37] A multiple feedback parameter contact force closed-loop control piezoelectric actuator with high working performance retention
    Gao, Jingwen
    Zhang, Jianhai
    Wang, Zhiming
    She, Mingyun
    Tian, Hailong
    Li, Jianping
    Zhou, Dudu
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 212
  • [38] On closed-loop vibrational control of underactuated mechanical systems
    Tahmasian, Sevak
    Woolsey, Craig A.
    NONLINEAR DYNAMICS, 2022, 108 (01) : 329 - 347
  • [39] Closed-loop control of power system transient stability(6): control location selection
    Zhang, Baohui
    Wang, Huaiyuan
    Yang, Songhao
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (01): : 1 - 5and12
  • [40] Active Closed-Loop Gap Control for Aerostatic Bearing
    Renn, Jyh-Chyang
    Chiou, Yaw-Ming
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON INTELLIGENT TECHNOLOGIES AND ENGINEERING SYSTEMS (ICITES2014), 2016, 345 : 1 - 7