Determination of IGF-I in horse plasma by LC electrospray ionisation mass spectrometry

被引:22
作者
Popot, Marie-Agnes [1 ]
Woolfitt, Adrian R. [2 ]
Garcia, Patrice [1 ]
Tabet, Jean-Claude [3 ]
机构
[1] Lab Courses Hippiques, F-91370 Verrieres Le Buisson, France
[2] Ctr Dis Control & Prevent, Atlanta, GA 30341 USA
[3] Univ Paris 06, CNRS, UMR 7613, Grp Spectrometrie Masse,Struct & Fonct Mol Bio Ac, F-75225 Paris 05, France
关键词
bioanalytical methods; biological samples; mass spectrometry;
D O I
10.1007/s00216-008-1889-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The insulin-like-growth factor (IGF-I) peptide is considered to be the main indirect marker for growth hormone administration (GH) in a horse. Further to a previous investigation on measurement of IGF-I in plasma samples by mass spectrometry, this study focuses on quantitative and qualitative analysis of intact IGF-I in horse plasma. First, protein-transposing software has been developed for IGF-I to facilitate its quantification by HPLC-electrospray-ion-trap mass spectrometry. Second, product-ion scan experiments on IGF-I have been conducted on standard samples, non-fortified equine plasma samples, fortified plasma samples, and equine GH post-administration samples. This "top-down" approach method enables characterisation of fragment ions corresponding to the carboxy terminal end, which can be useful for the confirmation of the presence of IGF-I in plasma samples.
引用
收藏
页码:1843 / 1852
页数:10
相关论文
共 40 条
[31]   Ion trap collisional activation of the (M+2H)2+-(M+17H)17+ ions of human hemoglobin β-chain [J].
Schaaff, TG ;
Cargile, BJ ;
Stephenson, JL ;
McLuckey, SA .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :899-907
[32]   COLLISIONAL ACTIVATION AND COLLISION-ACTIVATED DISSOCIATION OF LARGE MULTIPLY CHARGED POLYPEPTIDES AND PROTEINS PRODUCED BY ELECTROSPRAY IONIZATION [J].
SMITH, RD ;
LOO, JA ;
BARINAGA, CJ ;
EDMONDS, CG ;
UDSETH, HR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (01) :53-65
[33]   Doping control analysis of intact rapid-acting insulin analogues in human urine by liquid chromatography -: Tandem mass spectrometry [J].
Thevis, M ;
Thomas, A ;
Delahaut, P ;
Bosseloir, A ;
Schänzer, W .
ANALYTICAL CHEMISTRY, 2006, 78 (06) :1897-1903
[34]   Qualitative determination of synthetic analogues of insulin in human plasma by immunoaffinity purification and liquid chromatography-tandem mass spectrometry for doping control purposes [J].
Thevis, M ;
Thomas, A ;
Delahaut, P ;
Bosseloir, A ;
Schänzer, W .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3579-3585
[35]   Recommended criteria for the mass spectrometric identification of target peptides and proteins (<8 kDa) in sports drug testing [J].
Thevis, Mario ;
Loo, Joseph A. ;
Loo, Rachel R. Ogorzalek ;
Schaenzer, Wilhelm .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (03) :297-304
[36]   Combined infrared multiphoton dissociation and electron capture dissociation with a hollow electron beam in Fourier transform ion cyclotron resonance mass spectrometry [J].
Tsybin, YO ;
Witt, M ;
Baykut, G ;
Kjeldsen, F ;
Håkansson, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (15) :1759-1768
[37]   Charge state dependent ion trap collision-induced dissociation of reduced bovine and porcine trypsin cations [J].
Watson, Dawn J. ;
McLuckey, Scott A. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 255 :53-64
[38]   MULTIPLE CHARGING IN ELECTROSPRAY IONIZATION OF POLY(ETHYLENE GLYCOLS) [J].
WONG, SF ;
MENG, CK ;
FENN, JB .
JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (02) :546-550
[39]   Determination of binding sites in carboplatin-bound cytochrome c using electrospray ionization mass spectrometry and tandem mass spectrometry [J].
Yang, GS ;
Miao, R ;
Jin, C ;
Mei, YH ;
Tang, HW ;
Hong, J ;
Guo, ZJ ;
Zhu, LG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08) :1005-1016
[40]   Consecutive ion activation for top down mass spectrometry: Improved protein sequencing by nozzle-skimmer dissociation [J].
Zhai, H ;
Han, XM ;
Breuker, K ;
McLafferty, FW .
ANALYTICAL CHEMISTRY, 2005, 77 (18) :5777-5784