Effective lengths of braced frame columns

被引:1
|
作者
Girgin, Konuralp [1 ]
Ozmen, Gunay [1 ]
机构
[1] Istanbul Tech Univ, Fac Civil Engn, TR-34469 Istanbul, Turkey
关键词
buckling load; buckling length; effective length; non-sway mode; braced frames; isolated subassembly; multi-storey frames; design codes;
D O I
10.12989/sem.2008.28.2.189
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In several design codes and specifications, simplified formulae and charts are given for determining the effective lengths of frame columns. It is shown that these formulae may yield rather erroneous results in certain cases. This is due to the fact that, the code formulae utilise only local stiffness distributions. In this paper, a simplified procedure for determining approximate values for the buckling loads of braced frames is developed. The procedure utilises a fictitious load analysis of frames and yields errors less than 10%, which may be considered suitable for design purposes. The proposed procedure is applied to several numerical examples and it is shown that all the errors are in the acceptable range.
引用
收藏
页码:189 / 206
页数:18
相关论文
共 33 条
  • [21] Direct Evaluation of Effective Lengths of Vibrating Cables Using Responses from Dual/Three Transducers
    Yu, Chih-Peng
    Lai, Jiunnren
    Cheng, Chia-Chi
    Chiang, Chih-Hung
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2013, 16 (01): : 51 - 60
  • [22] Improved stiffness distribution factors for evaluation of effective buckling lengths in multi-story sway frames
    Gantes, CJ
    Mageirou, GE
    ENGINEERING STRUCTURES, 2005, 27 (07) : 1113 - 1124
  • [23] Method of determining effective length factor of column within frame-corewall structures
    Fan Z.
    Xu Y.
    Mu Z.
    Liu T.
    Han W.
    Wu H.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 26 - 37
  • [24] Analytical and experimental studies on a two-level yielding rocking steel frame with buckling-restrained columns (TYRSFB)
    Jiang, Qing
    Wang, Hanqin
    Feng, Yulong
    Chong, Xun
    Hou, Linbing
    ENGINEERING STRUCTURES, 2021, 235
  • [25] Improved system buckling analysis of effective lengths of girder and tower members in steel cable-stayed bridges
    Yoo, Hoon
    Choi, Dong-Ho
    COMPUTERS & STRUCTURES, 2009, 87 (13-14) : 847 - 860
  • [26] Effective bending stiffness of steel-concrete composite columns with multiple encased steel profiles
    Chrzanowski, M.
    Odenbreit, C.
    Obiala, R.
    Bogdan, T.
    Degee, H.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 181
  • [27] Seismic response evaluation of a five-story buckling-restrained braced frame using multi-element pseudo-dynamic hybrid simulations
    Mojiri, Saeid
    Mortazavi, Pedram
    Kwon, Oh-Sung
    Christopoulos, Constantin
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (12) : 3243 - 3265
  • [28] Fillet weld effective lengths in CHS X-connections. II: Finite element modelling, parametric study and design
    Tousignant, Kyle
    Packer, Jeffrey A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 141 : 77 - 90
  • [29] Column effective lengths considering inter-story and inter-column interactions in sway-permitted frames
    Tong, GS
    Wang, JP
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (05) : 413 - 423
  • [30] Tension force identification for cable of various end-restraints using equivalent effective vibration lengths of mode pairs
    Syamsi, Muhammad Ibnu
    Wang, Chung-Yue
    Nguyen, Van-Son
    MEASUREMENT, 2022, 197