Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures

被引:77
|
作者
String, A
Berber, E
Foroutani, A
Macho, JR
Pearl, JM
Siperstein, AE
机构
[1] Cleveland Clin Fdn, Dept Gen Surg, Cleveland, OH 44195 USA
[2] Univ Pacific, Dept Surg, Mt Zion Med Ctr, San Francisco, CA 94115 USA
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 2001年 / 15卷 / 06期
关键词
laparoscopic surgery; optical access trocar; pneumoperitoneum; Veress needle;
D O I
10.1007/s004640080056
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The use of the Veress needle in laparoscopy to create the pneumoperitoneum has inherent risks; it may cause vascular and visceral injuries. The open technique is compromised by the leakage of carbon dioxide and can also be time consuming. One alternative is to enter the abdomen using an optical trocar under direct view. Our aim was to determine whether the optical access trocar can be used to effect a safe and rapid entry in various laparoscopic procedures. Methods: Over a 4-year period, the Optiview trocar was used for initial entry in 650 laparoscopic procedures. The procedures included cholecystectomy (n = 282), transabdominal inguinal hernia repair (n = 76), radiofrequency ablation of liver tumors (n = 73), adrenalectomy (n = 54), appendectomy(n = 41), colorectal surgery (n = 39), and various other procedures (n = 85). The following parameters were analyzed: presence of previous abdominal operations, site and duration of entry, and complications. Results: Of the 650 patients, 156 (24%) had had previous abdominal operations. In 25 cases, previous trocar sites were reused for optical access. The optical trocar was inserted at the umbilicus in 495 patients (76%), in the right upper quadrant in 77 (12%), in the left upper quadrant in 26 (4%), in the upper midline in eight (1%), in the right Lower quadrant in six (0.9%), and in the left lower quadrant in three (0.5%). In 35 patients undergoing posterior adrenalectomy, optical trocars were used to enter Gerota's space. Mean (SD) entry times were 92 (45) sec at the umbilical site, 114 (30) sec at the back, and 77 (35) sec at the remaining sites. Complications (0.3%) included one injury to the bowel and one injury to the gallbladder; however, they were recognized and repaired immediately. Conclusions: To our knowledge, this report comprises the largest series in which the optical access trocar was used for laparoscopic surgery. This device provides the basis for a safe and fast technique for initial trocar placement: it also has the potential to reduce costs. Thanks to our favorable experience, the optical trocar method has become the standard technique for abdominal access in our laparoscopic practice since 1995.
引用
收藏
页码:570 / 573
页数:4
相关论文
共 12 条
  • [1] Experience with the optical access trocar for safe and rapid entry in the performance of laparoscopic gastric bypass
    Berch, Barry R.
    Torquati, Alfonso
    Lutfi, Rami Edward
    Richards, William O.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (08): : 1238 - 1241
  • [2] Experience with the optical access trocar for safe and rapid entry in the performance of laparoscopic gastric bypass
    Barry R. Berch
    Alfonso Torquati
    Rami Edward Lutfi
    William O. Richards
    Surgical Endoscopy And Other Interventional Techniques, 2006, 20 : 1238 - 1241
  • [3] Experience with optical trocar in performing laparoscopic procedures
    McKernan, JB
    Finley, CR
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2002, 12 (02) : 96 - 99
  • [4] PNEUMOPERITONEUM BY DIRECT TROCAR INSERTION: SAFE LAPAROSCOPIC ACCESS
    Kumar, Rajneesh
    Hastir, Ankur
    Bandlish, M. K.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (15): : 2432 - 2437
  • [5] Bladeless Direct Optical Trocar Insertion in Laparoscopic Procedures on the Obese Patient
    Tinelli, Andrea
    Malvasi, Antonio
    Mynbaev, Ospan A.
    Tsin, Daniel Alberto
    Davila, Fausto
    Dominguez, Guillermo
    Perrone, Emanuele
    Nezhat, Farr R.
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2013, 17 (04) : 521 - 528
  • [6] Initial laparoscopic access using an optical trocar without pneumoperitoneum is safe and effective in the morbidly obese
    Rabl, Charlotte
    Palazzo, Francesco
    Aoki, Hisae
    Campos, Guilherme M.
    SURGICAL INNOVATION, 2008, 15 (02) : 126 - 131
  • [7] Optical trocar access for initial trocar placement in laparoscopic gastrointestinal surgery: A propensity score-matching analysis
    Tanaka, Chie
    Fujiwara, Michitaka
    Kanda, Mitsuro
    Murotani, Kenta
    Iwata, Naoki
    Hayashi, Masamichi
    Kobayashi, Daisuke
    Yamada, Suguru
    Kodera, Yasuhiro
    ASIAN JOURNAL OF ENDOSCOPIC SURGERY, 2019, 12 (01) : 37 - 42
  • [8] Using an Optical Trocar for Laparoscopic Access in Overweight and Obese Children
    Livesey, Emily
    Jones, Niall
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2010, 20 (02): : 205 - 206
  • [9] Primary midline peritoneal access with optical trocar is safe and effective in morbidly obese patients
    Sabeti, Nari
    Tarnoff, Michael
    Kim, Julie
    Shikora, Scott
    SURGERY FOR OBESITY AND RELATED DISEASES, 2009, 5 (05) : 610 - 614
  • [10] Safe and Rapid Laparoscopic Access—a New Approach
    Jared L. Antevil
    Sunil Bhoyrul
    Mathew E. Brunson
    Mark A. Vierra
    Nayan D. Swadia
    World Journal of Surgery, 2005, 29 : 800 - 803