Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla

被引:98
作者
Frauenrath, Tobias [1 ]
Hezel, Fabian [1 ]
Renz, Wolfgang [1 ,2 ]
d'Orth, Thibaut de Geyer [1 ]
Dieringer, Matthias [1 ,3 ,4 ]
von Knobelsdorff-Brenkenhoff, Florian [3 ,4 ]
Prothmann, Marcel [4 ]
Schulz-Menger, Jeanette [1 ,3 ,4 ]
Niendorf, Thoralf [1 ,3 ]
机构
[1] Max Delbruck Ctr Mol Med, Berlin Ultrahigh Field Facil, Berlin, Germany
[2] Siemens Healthcare, Erlangen, Germany
[3] Humboldt Univ, Expt & Clin Res Ctr, Charite Campus Buch, Berlin, Germany
[4] Med Univ Berlin, HELIOS Klinikum Berlin Buch, Working Grp Cardiovasc Magnet Resonance, Charite Campus Buch, Berlin, Germany
关键词
CINE MRI; CLINICAL-APPLICATIONS; FEASIBILITY; STETHOSCOPE; MOTION;
D O I
10.1186/1532-429X-12-67
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results: ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Delta t = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Delta t = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 +/- 0.5, ACT = 2.4 +/- 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 +/- 0.5, POX = 2.0 +/- 0.5, p = 0.34). Conclusions: The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.
引用
收藏
页数:14
相关论文
共 33 条
  • [1] BECKER M, 2009, EUR RADIOL
  • [2] BLAND JM, 1986, LANCET, P307
  • [3] BRANDTS A, 2010, MAGN RESON MED
  • [4] BRANTS A, 2010, P INT SOC MAG RES ME, P1299
  • [5] Fiber-optic stethoscope: A cardiac monitoring and gating system for magnetic resonance microscopy
    Brau, ACS
    Wheeler, CT
    Hedlund, LW
    Johnson, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) : 314 - 321
  • [6] Prospective self-gating for simultaneous compensation of cardiac and respiratory motion
    Buehrer, Martin
    Curcic, Jelena
    Boesiger, Peter
    Kozerke, Sebastian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 683 - 690
  • [7] THE RF COIL AS A SENSITIVE MOTION DETECTOR FOR MAGNETIC-RESONANCE IMAGING
    BUIKMAN, D
    HELZEL, T
    ROSCHMANN, P
    [J]. MAGNETIC RESONANCE IMAGING, 1988, 6 (03) : 281 - 289
  • [8] Chia JM, 2000, J MAGN RESON IMAGING, V12, P678, DOI 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO
  • [9] 2-5
  • [10] Automated rectilinear self-gated cardiac cine imaging
    Crowe, ME
    Larson, AC
    Zhang, Q
    Carr, J
    White, RD
    Li, DB
    Simonetti, OP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 782 - 788