Breakage and migration of a high-speed dental hand-piece bur during mandibular third molar extraction: Two case reports

被引:10
作者
Matsuda, Shinpei [1 ]
Yoshimura, Hitoshi [1 ]
Yoshida, Hisato [1 ]
Sano, Kazuo [1 ,2 ]
机构
[1] Univ Fukui, Fac Med Sci, Dept Dent & Oral Surg, Unit Sensory & Locomotor Med,Div Med, 23-3 Matsuokashimoaizuki,Eiheiji Cho, Fukui 9101193, Japan
[2] Fukui Dent Assoc, Oral Care Support Ctr, Fukui, Japan
关键词
high-speed dental hand-piece bur; iatrogenic foreign body; mandibular third molar extraction;
D O I
10.1097/MD.0000000000019177
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rationale:Tooth extraction is a common dental surgical procedure. There is a possibility that various complications often occur during third molar tooth extractions.Patient concerns:The authors report herein 2 cases of migration of a high-speed dental hand-piece bur during mandibular third molar extraction-one case with the iatrogenic foreign body migrating into the mandibular body and another case with the iatrogenic foreign body migrating into the floor of mouth are reported.Diagnosis:The patient was diagnosed with the iatrogenic foreign body associated with mandibular third molar extraction by imaging examinations.Interventions:The authors performed elective surgery to remove the foreign body under general anesthesia in Case 1, and performed emergency surgery to remove the foreign body under local anesthesia in Case 2.Outcomes:The foreign bodies were removed, and complete removal of the foreign bodies was confirmed by postoperative x-ray examination. The patients' postoperative courses were uneventful.Lessons:The selection of adequate surgical procedures and instruments will prevent the occurrence of iatrogenic foreign bodies. If migration accidents occur, their positions should first be confirmed by imaging examinations. Dentists and/or oral surgeons should perform removal operations considering the degree of emergency based on the results of imaging examinations.
引用
收藏
页数:3
相关论文
共 9 条
[1]  
Ali FM., 2016, MOJ Clin Med Case Rep, V4, P152
[2]  
Bouloux Gary F, 2007, Oral Maxillofac Surg Clin North Am, V19, P117, DOI 10.1016/j.coms.2006.11.013
[3]   Application of a real-time 3-dimensional navigation system for treatment of synovial chondromatosis of the temporomandibular joint A case report [J].
Matsuda, Shinpei ;
Yoshimura, Hitoshi ;
Sano, Kazuo .
MEDICINE, 2019, 98 (18)
[4]   Application of a Real-Time Three-Dimensional Navigation System to Dental Implant Removal: A Five-Year Single-Institution Experience [J].
Matsuda, Shinpei ;
Yoshimura, Hitoshi ;
Yoshida, Hisato ;
Ohta, Keiichi ;
Ueno, Takashi ;
Sano, Kazuo .
JOURNAL OF HARD TISSUE BIOLOGY, 2018, 27 (04) :359-362
[5]   Usefulness of Computed Tomography Image Processing by OsiriX Software in Detecting Wooden and Bamboo Foreign Bodies [J].
Matsuda, Shinpei ;
Yoshimura, Hitoshi ;
Yoshida, Hisato ;
Ryoke, Takashi ;
Yoshida, Takashi ;
Aikawa, Naoyuki ;
Sano, Kazuo .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[6]   Assessment of Migrated Foreign Bodies in the Maxillae by X-ray Fluorescence Spectrometry [J].
Matsuda, Shinpei ;
Ohba, Seigo ;
Yoshimura, Hitoshi ;
Kobayashi, Junichi ;
Watanabe, Ikuya ;
Sano, Kazuo .
JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) :E233-E235
[7]   Investigation of the Electric Handpiece-related Pneumomediastinum and Cervicofacial Subcutaneous Emphysema in Third Molar Surgery [J].
Ohta, Keiichi ;
Yoshimura, Hitoshi ;
Ryoke, Takashi ;
Matsuda, Shinpei ;
Yoshida, Hisato ;
Omori, Masahiro ;
Yamamoto, Satoshi ;
Ueno, Takaaki ;
Sano, Kazuo .
JOURNAL OF HARD TISSUE BIOLOGY, 2019, 28 (01) :79-85
[8]  
Rajaran JR, 2017, BMJ CASE REP, P2017
[9]   Accidental displacement of a high-speed handpiece bur during mandibular third molar surgery: a case report [J].
Yalcin, Serhat ;
Aktas, Irem ;
Emes, Yusuf ;
Atalay, Belir .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (03) :E29-E31