Differential Refractometric Biosensor for Reliable Human IgG Detection: Proof of Concept

被引:9
|
作者
Mendes, Joao P. [1 ,2 ,3 ]
Coelho, Luis C. C. [2 ,4 ]
Jorge, Pedro A. S. [2 ,4 ]
Pereira, Carlos M. [1 ,3 ]
机构
[1] Univ Porto, Fac Ciencias, Ctr Invest Quim UP CIQUP, Inst Ciencias Moleculares IMS,Dept Quim & Bioquim, Rua Campo Alegre 687, P-4169007 Porto, Portugal
[2] Univ Porto, Fac Ciencias, INESC TEC Inst Engn Sistemas & Computadores Tecno, Dept Fis & Astron, Rua Campo Alegre 687, P-4169007 Porto, Portugal
[3] Univ Porto, Fac Ciencias, Dept Quim & Bioquim, Rua Campo Alegre 687, P-4169007 Porto, Portugal
[4] Univ Porto, Fac Ciencias, Dept Fis & Astron, Rua Campo Alegre 687, P-4169007 Porto, Portugal
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 07期
关键词
refractometric platform; optical sensing; long period fiber gratings; molecular imprinting; IgG antibodies; LONG-PERIOD FIBER; MOLECULARLY IMPRINTED POLYMER; SURFACE-PLASMON RESONANCE; OPTICAL-FIBERS; SENSOR; NANOPARTICLES; PERSPECTIVES; TEMPERATURE; PERFORMANCE; FABRICATION;
D O I
10.3390/bios12070515
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensing platform based on long-period fiber gratings (LPFGs) for direct, fast, and selective detection of human immunoglobulin G (IgG; Mw = 150 KDa) was developed and characterized. The transducer's high selectivity is based on the specific interaction of a molecularly imprinted polymer (MIPs) design for IgG detection. The sensing scheme is based on differential refractometric measurements, including a correction system based on a non-imprinted polymer (NIP)-coated LPFG, allowing reliable and more sensitive measurements, improving the rejection of false positives in around 30%. The molecular imprinted binding sites were performed on the surface of a LPFG with a sensitivity of about 130 nm/RIU and a FOM of 16 RIU-1. The low-cost and easy to build device was tested in a working range from 1 to 100 nmol/L, revealing a limit of detection (LOD) and a sensitivity of 0.25 nmol/L (0.037 mu g/mL) and 0.057 nm.L/nmol, respectively. The sensor also successfully differentiates the target analyte from the other abundant elements that are present in the human blood plasma.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] A split aptamer-labeled ratiometric fluorescent biosensor for specific detection of adenosine in human urine
    You, Junhui
    You, Zhengyi
    Xu, Xin
    Ji, Jiangrong
    Lu, Tian
    Xia, Yuhong
    Wang, Lipin
    Zhang, Liying
    Du, Shuhu
    MICROCHIMICA ACTA, 2019, 186 (01)
  • [22] Electrochemical Biosensor for Sensitive Detection of Hepatitis B in Human Plasma
    Honorato de Castro, Ana Cristina
    Kochi, Leandro Toshio
    Rodrigueiro Flauzino, Jose Manuel
    Costa Nunes Soares, Marcia Maria
    Alves, Valeria Almeida
    da Silva, Luis Antonio
    Madurro, Joao Marcos
    Brito-Madurro, Ana Graci
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2022, 194 (06) : 2604 - 2619
  • [23] Application of a Plasmonic Biosensor for Detection of Human-Liver Tissues
    V. A. Popescu
    Plasmonics, 2018, 13 : 575 - 582
  • [24] Enhancing sensitivity of surface plasmon resonance biosensor by Ag nanocubes/chitosan composite for the detection of mouse IgG
    Zhang, Di
    Sun, Ying
    Wu, Qiong
    Ma, Pinyi
    Zhang, Hua
    Wang, Yuanpeng
    Song, Daqian
    TALANTA, 2016, 146 : 364 - 368
  • [25] Ag(I)-cysteamine complex based electrochemical stripping immunoassay: Ultrasensitive human IgG detection
    Noh, Hui-Bog
    Rahman, Md Aminur
    Yang, Jee Eun
    Shim, Yoon-Bo
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) : 4429 - 4435
  • [26] Electropolymerised molecularly imprinted polymers for the heat-transfer based detection of microorganisms: A proof-of-concept study using yeast
    Jamieson, O.
    Betlem, K.
    Mansouri, N.
    Crapnell, R. D.
    Vieira, F. S.
    Hudson, A.
    Banks, C. E.
    Liauw, C. M.
    Gruber, J.
    Zubko, M.
    Whitehead, K. A.
    Peeters, M.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 24
  • [27] Photonic crystal-based biosensor for detection of human red blood cells parasitized by plasmodium falciparum
    Rashidnia, Ali
    Pakarzadeh, Hassan
    Hatami, Mohsen
    Ayyanar, Natesan
    OPTICAL AND QUANTUM ELECTRONICS, 2022, 54 (01)
  • [28] Development and characterization of an electrochemical biosensor for creatinine detection in human urine based on functional molecularly imprinted polymer
    Diouf, A.
    Motia, S.
    El Hassani, N. El Alami
    El Bari, N.
    Bouchikhi, B.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 44 - 53
  • [29] Microwave biosensor for the detection of growth inhibition of human liver cancer cells at different concentrations of chemotherapeutic drug
    Zhao, Jun-Ming
    Wang, Yi-Ke
    Shi, Bo-Wen
    Wang, Yan-Xiong
    Jiang, Yan-Feng
    Yang, Gang-Long
    Gao, Xiao-Dong
    Qiang, Tian
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [30] MoSe2-Au Based Sensitivity Enhanced Optical Fiber Surface Plasmon Resonance Biosensor for Detection of Goat-Anti-Rabbit IgG
    Liu, Kun
    Zhang, Jiahang
    Jiang, Junfeng
    Xu, Tianhua
    Wang, Shuang
    Chang, Pengxiang
    Zhang, Zhao
    Ma, Jinying
    Liu, Tiegen
    IEEE ACCESS, 2020, 8 : 660 - 668