Accuracy assessment of pedicle screw insertion with patient specific 3D-printed guides through superimpose CT-analysis in thoracolumbar spinal deformity surgery

被引:14
作者
Cool, J. [1 ,2 ]
van Schuppen, J. [3 ]
de Boer, M. A. [1 ,2 ]
van Royen, B. J. [1 ,2 ,4 ]
机构
[1] Univ Amsterdam, Amsterdam UMC, Dept Orthoped Surg, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[2] Vrije Univ, Amsterdam Movement Sci, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam Movement Sci, Amsterdam, Netherlands
[4] Univ Amsterdam, Amsterdam UMC, Emma Childrens Hosp, Amsterdam, Netherlands
关键词
3D-printed guides; Pedicle screws; Superimpose CT-analysis; Spinal deformity surgery; RADIATION-EXPOSURE; FREE-HAND; PLACEMENT; CANCER;
D O I
10.1007/s00586-021-06951-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose In order to avoid pedicle screw misplacement in posterior spinal deformity surgery, patient specific 3D-printed guides can be used. An accuracy assessment of pedicle screw insertion can be obtained by superimposing CT-scan images from a preoperative plan over those of the postoperative result. The aim of this study is to report on the accuracy of drill guide assisted pedicle screw placement in thoracolumbar spinal deformity surgery by means of a superimpose CT-analysis. Methods Concomitant with the clinical introduction of a new technique for drill guide assisted pedicle screw placement, the accuracy of pedicle screw insertion was analyzed in the first patients treated with this technique by using superimpose CT-analysis. Deviation from the planned ideal intrapedicular screw trajectory was classified according to the Gertzbein scale. Results Superimpose CT-analysis of 99 pedicle screws in 5 patients was performed. The mean linear deviation was 0.92 mm, the mean angular deviation was 2.92 degrees with respect to the preoperatively planned pedicle screw trajectories. According to the Gertzbein scale, 100% of screws were found to be positioned within the "safe zone". Conclusion The evaluated patient specific 3D-printed guide technology was demonstrated to constitute a safe and accurate tool for precise pedicle screw insertion in spinal deformity surgeries. Superimpose CT-analysis showed a 100% accuracy of pedicle screw placement without any violation of the pedicle wall or other relevant structures. We recommend a superimpose CT-analysis for the first consecutive patients when introducing new technologies into daily clinical practice, such as intraoperative imaging, navigation or robotics.
引用
收藏
页码:3216 / 3224
页数:9
相关论文
共 22 条
[1]   Freehand Thoracic Pedicle Screw Placement: Review of Existing Strategies and a Step-by-Step Guide Using Uniform Landmarks for All Levels [J].
Avila, Mauricio J. ;
Baaj, Ali A. .
CUREUS, 2016, 8 (02)
[2]   Pedicle screw insertion with patient-specific 3D-printed guides based on low-dose CT scan is more accurate than free-hand technique in spine deformity patients: a prospective, randomized clinical trial [J].
Cecchinato, Riccardo ;
Berjano, Pedro ;
Zerbi, Alberto ;
Damilano, Marco ;
Redaelli, Andrea ;
Lamartina, Claudio .
EUROPEAN SPINE JOURNAL, 2019, 28 (07) :1712-1723
[3]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[4]  
Etemadifar Mohammadreza, 2017, Adv Biomed Res, V6, P19, DOI 10.4103/2277-9175.201331
[5]   Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study [J].
Farshad, Mazda ;
Betz, Michael ;
Farshad-Amacker, Nadja A. ;
Moser, Manuel .
EUROPEAN SPINE JOURNAL, 2017, 26 (03) :738-749
[6]   Improving safety in spinal deformity surgery: advances in navigation and neurologic monitoring [J].
Flynn, John M. ;
Sakai, Denis S. .
EUROPEAN SPINE JOURNAL, 2013, 22 :S131-S137
[7]   Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques [J].
Gelalis, Ioannis D. ;
Paschos, Nikolaos K. ;
Pakos, Emilios E. ;
Politis, Angelos N. ;
Arnaoutoglou, Christina M. ;
Karageorgos, Athanasios C. ;
Ploumis, Avraam ;
Xenakis, Theodoros A. .
EUROPEAN SPINE JOURNAL, 2012, 21 (02) :247-255
[8]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[9]   Cortical pedicle screw placement in lumbar spinal surgery with a patient-matched targeting guide: A cadaveric study [J].
Kaito, Takashi ;
Matsukawa, Keitaro ;
Abe, Yuichiro ;
Fiechter, Meinrad ;
Zhu, Xia ;
Fantigrossi, Alfonso .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (06) :865-869
[10]   Improving Patient Safety in the ICU by Prospective Identification of Missing Safety Barriers Using the Bow-Tie Prospective Risk Analysis Model [J].
Kerckhoffs, Monika C. ;
van der Sluijs, Alexander E. ;
Binnekade, Jan M. ;
Dongelmans, Dave A. .
JOURNAL OF PATIENT SAFETY, 2013, 9 (03) :154-159