Novel Surfaces in Extracorporeal Membrane Oxygenation Circuits

被引:93
作者
Ontaneda, Andrea [1 ]
Annich, Gail M. [1 ]
机构
[1] Univ Toronto, Hosp Sick Children, Dept Crit Care Med, Toronto, ON, Canada
关键词
extracorporeal circuit; anticoagulation; blood-surface interaction; surface coating; nitric oxide; endothelium; CARDIOPULMONARY BYPASS CIRCUITS; NITRIC-OXIDE RELEASE; IN-SITU ENDOTHELIALIZATION; HEPARIN-COATED CIRCUITS; LIFE-SUPPORT; INFLAMMATORY RESPONSE; CATALYTIC GENERATION; REDUCED COMPLEMENT; PLATELET-ADHESION; BLOOD COMPONENTS;
D O I
10.3389/fmed.2018.00321
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The balance between systemic anticoagulation and clotting is challenging. In normal hemostasis, the endothelium regulates the balance between anticoagulant and prothrombotic systems. It becomes particularly more challenging to maintain this physiologic hemostasis when we are faced with extracorporeal life support therapies, where blood is continuously in contact with a foreign extracorporeal circuit surface predisposing a prothrombotic state. The blood-surface interaction during extracorporeal life support therapies requires the use of systemic anticoagulation to decrease the risk of clotting. Unfractionated heparin is the most common anticoagulant agent widely used in this setting. New trends include the use of direct thrombin inhibitor agents for systemic anticoagulation; and surface modifications that aim to overcome the blood-biomaterial surface interaction by modifying the hydrophilicity or hydrophobicity of the polymer surface; and coating the circuit with substances that will mimic the endothelium or anti-thrombotic agents. To improve hemocompatibility in an extracorporeal circuit, replication of the anti-thrombotic and anti-inflammatory properties of the endothelium is ideal. Surface modifications can be classified into three major groups: biomimetic surfaces (heparin, nitric oxide, and direct thrombin inhibitors); biopassive surfaces [phosphorylcholine, albumin, and poly-2-methoxyethylacrylate]; and endothelialization of blood contacting surface. The focus of this paper will be to review both present and future novel surface modifications that can obviate the need for systemic anticoagulation during extracorporeal life support therapies.
引用
收藏
页数:9
相关论文
共 82 条
[1]   Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters [J].
Amoako, Kagya A. ;
Archangeli, Christopher ;
Handa, Hitesh ;
Major, Terry ;
Meyerhoff, Mark E. ;
Annich, Gail M. ;
Bartlett, Robert H. .
ASAIO JOURNAL, 2012, 58 (03) :238-246
[2]   Extracorporeal life support: the precarious balance of hemostasis [J].
Annich, G. M. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 :S336-S342
[3]   Reduced platelet activation and thrombosis in extracorporeal circuits coated with nitric oxide release polymers [J].
Annich, GM ;
Meinhardt, JP ;
Mowery, KA ;
Ashton, BA ;
Merz, SI ;
Hirschl, RB ;
Meyerhoff, ME ;
Bartlett, RH .
CRITICAL CARE MEDICINE, 2000, 28 (04) :915-920
[4]   Induction of EPC homing on biofunctionalized vascular grafts for rapid in vivo self-endothelialization - A review of current strategies [J].
Avci-Adali, Meltem ;
Ziemer, Gerhard ;
Wendel, Hans P. .
BIOTECHNOLOGY ADVANCES, 2010, 28 (01) :119-129
[5]   An omniphobic lubricant-infused coating produced by chemical vapor deposition of hydrophobic organosilanes attenuates clotting on catheter surfaces [J].
Badv, Maryam ;
Jaffer, Iqbal H. ;
Weitz, Jeffrey I. ;
Didar, Tohid F. .
SCIENTIFIC REPORTS, 2017, 7
[6]   Purity of the sacred lotus, or escape from contamination in biological surfaces [J].
Barthlott, W ;
Neinhuis, C .
PLANTA, 1997, 202 (01) :1-8
[7]   Anticoagulation for Extracorporeal Life Support: Direct Thrombin Inhibitors and Heparin [J].
Coughlin, Megan A. ;
Bartlett, Robert H. .
ASAIO JOURNAL, 2015, 61 (06) :652-655
[8]   Nitric oxide-eluting nanocomposite for cardiovascular implants [J].
de Mel, Achala ;
Naghavi, Noora ;
Cousins, Brian G. ;
Clatworthy, Innes ;
Hamilton, George ;
Darbyshire, Arnold ;
Seifalian, Alexander M. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (03) :917-929
[9]   Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface [J].
De Somer, F ;
François, K ;
van Oeveren, W ;
Poelaert, J ;
De Wolf, D ;
Ebels, T ;
Van Nooten, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (05) :602-606
[10]   The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass [J].
de Vroege, R ;
Huybregts, R ;
van Oeveren, W ;
van Klarenbosch, J ;
Linley, G ;
Mutlu, J ;
Jansen, E ;
Hack, E ;
Eijsman, L ;
Wildevuur, C .
ARTIFICIAL ORGANS, 2005, 29 (06) :490-497