Reference-independent wide field fluorescence lifetime measurements using Frequency-Domain (FD) technique based on phase and amplitude crossing point

被引:8
作者
Yahav, Gilad [1 ,2 ]
Barnoy, Eran [1 ,2 ]
Roth, Nir [1 ,2 ]
Turgeman, Lior [3 ]
Fixler, Dror [1 ,2 ]
机构
[1] Bar Ilan Univ, Fac Engn, IL-5290002 Ramat Gan, Israel
[2] Bar Ilan Univ, Inst Nanotechnol & Adv Mat, IL-5290002 Ramat Gan, Israel
[3] Univ Pittsburgh, Joseph M Katz Grad Sch Business, Roberto Clemente Dr, Pittsburgh, PA 15260 USA
关键词
Fluorescence Lifetime Imaging Microscopy (FLIM); Fluorescence Intensity (FI); Fluorescence Lifetime (FLT); modulation depth; phase shift; Light Emitting Diode DC (LED DC); IMAGING MICROSCOPY; SPATIAL-RESOLUTION; DAPI; EXCITATION; DECAY; FLIM; CELL;
D O I
10.1002/jbio.201600220
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence lifetime imaging microscopy (FLIM) is an essential tool in many scientific fields such as biology and medicine thanks to the known advantages of the fluorescence lifetime (FLT) over the classical fluorescence intensity (FI). However, the frequency domain (FD) FLIM technique suffers from its strong dependence on the reference and its compliance to the sample. In this paper, we suggest a new way to calculate the FLT by using the crossing point (CRPO) between the modulation and phase FLTs measured over several light emitting diode (LED) DC currents values instead of either method alone. This new technique was validated by measuring homogeneous substances with known FLT, where the CRPO appears to be the optimal measuring point. Furthermore, the CRPO method was applied in heterogeneous samples. It was found that the CRPO in known mixed solutions is the weighted average of the used solutions. While measuring B16 and lymphocyte cells, the CRPO of the DAPI compound in single FLT regions was measured at 3.5 +/- 0.06 ns and at 2.83 +/- 0.07 ns, respectively, both of which match previous reports and multi-frequency analyses. This paper suggests the CRPO as a new method to extract the FLT in problematic cases such as high MCP gains and heterogeneous environments. [GRAPHICS] In traditional FD FLIM measurements, the variation in phase angle and modulation are measured. By measuring over varying DC currents, another variation is detected in the FLT determined through the phase and modulation methods, with the CRPO indicating the true FLT.
引用
收藏
页码:1198 / 1207
页数:10
相关论文
共 28 条
  • [21] Photoconversion of DAPI following UV or violet excitation can cause DAPI to fluoresce with blue or cyan excitation
    Piterburg, M.
    Panet, H.
    Weiss, A.
    [J]. JOURNAL OF MICROSCOPY, 2012, 246 (01) : 89 - 95
  • [22] Polar plot representation for frequency-domain analysis of fluorescence lifetimes
    Redford, GI
    Clegg, RM
    [J]. JOURNAL OF FLUORESCENCE, 2005, 15 (05) : 805 - 815
  • [23] Rueck A. C., 2005, P SOC PHOTO-OPT INS, P182
  • [24] Time-domain measurement of fluorescence lifetime variation with pH.
    Ryder, AG
    Power, S
    Glynn, TJ
    Morrison, JJ
    [J]. BIOMARKERS AND BIOLOGICAL SPECTRAL IMAGING, 2001, 4259 : 102 - 109
  • [25] Fluorescence life-time imaging and steady state polarization for examining binding of fluorophores to gold nanoparticles
    Schwartz, Shmulik
    Fixler, Dror
    Popovtzer, Rachela
    Shefi, Orit
    [J]. JOURNAL OF BIOPHOTONICS, 2015, 8 (11-12) : 944 - 951
  • [26] Multiple frequency fluorescence lifetime imaging microscopy
    Squire, A.
    Verveer, P.J.
    Bastiaens, Philippe I. H.
    [J]. Journal of Microscopy, 2000, 197 (02) : 136 - 149
  • [27] FLIM on a wide field fluorescence microscope
    van Geest, LK
    Stoop, KWJ
    [J]. LETTERS IN PEPTIDE SCIENCE, 2003, 10 (5-6): : 501 - 510
  • [28] Fluorescence lifetime imaging of DAPI-stained nuclei as a novel diagnostic tool for the detection and classification of B-cell chronic lymphocytic leukemia
    Yahav, Gilad
    Hirshberg, Abraham
    Salomon, Ophira
    Amariglio, Ninette
    Trakhtenbrot, Luba
    Fixler, Dror
    [J]. CYTOMETRY PART A, 2016, 89A (07) : 644 - 652