A real-time Monte Carlo tool for individualized dose estimations in clinical CT

被引:30
作者
Sharma, Shobhit [1 ,2 ]
Kapadia, Anuj [1 ,2 ,3 ]
Fu, Wanyi [2 ,5 ]
Abadi, Ehsan [2 ,5 ]
Segars, W. Paul [2 ,3 ,4 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ]
机构
[1] Duke Univ, Dept Phys, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
[5] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
computed tomography; Monte Carlo; radiation dose; real-time; patient-specific; GPU; SIMULATIONS; VALIDATION; IMPACT; SCANS;
D O I
10.1088/1361-6560/ab467f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The increasing awareness of the adverse effects associated with radiation exposure in computed tomography (CT) has necessesitated the quantification of dose delivered to patients for better risk assessment in the clinic. The current methods for dose quantification used in the clinic are approximations, lacking realistic models for the irradiation conditions utilized in the scan and the anatomy of the patient being imaged, which limits their relevance for a particular patient. The established gold-standard technique for individualized dose quantification uses Monte Carlo (MC) simulations to obtain patient-specific estimates of organ dose in anatomically realistic computational phantoms to provide patient-specific estimates of organ dose. Although accurate, MC simulations are computationally expensive, which limits their utility for time-constrained applications in the clinic. To overcome these shortcomings, a real-time GPU-based MC tool based on FDA's MC-GPU framework was developed for patient and scanner-specific dosimetry in the clinic. The tool was validated against (1) AAPM's TG-195 reference datasets and (2) physical measurements of dose acquired using TLD chips in adult and pediatric anthropomorphic phantoms. To demonstrate its utility towards providing individualized dose estimates, it was integrated with an automatic segmentation method for generating patient-specific models, which were then used to estimate patient- and scanner-specific organ doses for a select population of 50 adult patients using a clinically relevant CT protocol. The organ dose estimates were compared to corresponding dose estimates from a previously validated MC method based on Penelope. The dose estimates from our MC tool agreed within 5% for all organs (except thyroid) tabulated by TG-195 and within 10% for all TLD locations in the adult and pediactric phantoms, across all validation cases. Compared against Penelope, the organ dose estimates agreed within 3% on average for all organs in the patient population study. The average run duration for each patient was estimated at 23.79 s, representing a significant speedup (similar to 700x) over existing non-parallelized MC methods. The accuracy of dose estimates combined with a significant improvement in execution times suggests a feasible solution utilizing the proposed MC tool for real-time individualized dosimetry in the clinic.
引用
收藏
页数:12
相关论文
共 26 条
[1]   DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography [J].
Abadi, Ehsan ;
Harrawood, Brian ;
Sharma, Shobhit ;
Kapadia, Anuj ;
Segars, William P. ;
Samei, Ehsan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) :1457-1465
[2]   Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit [J].
Badal, Andreu ;
Badano, Aldo .
MEDICAL PHYSICS, 2009, 36 (11) :4878-4880
[3]   The Effect of Iodine-based Contrast Material on Radiation Dose at CT: It's Complicated [J].
Boone, John M. ;
Hernandez, Andrew M. .
RADIOLOGY, 2017, 283 (03) :624-627
[4]   Size-specific Dose Estimation for CT: How Should It Be Used and What Does It Mean? [J].
Brink, James A. ;
Morin, Richard L. .
RADIOLOGY, 2012, 265 (03) :666-668
[5]   Fast on-site Monte Carlo tool for dose calculations in CT applications [J].
Chen, Wei ;
Kolditz, Daniel ;
Beister, Marcel ;
Bohle, Robert ;
Kalender, Willi A. .
MEDICAL PHYSICS, 2012, 39 (06) :2985-2996
[6]   CT Radiation Dose: Current Controversies and Dose Reduction Strategies [J].
Costello, Justin E. ;
Cecava, Nathan D. ;
Tucker, Jonathan E. ;
Bau, Jennifer L. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) :1283-1290
[7]   Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography [J].
Deak, Paul ;
van Straten, Marcel ;
Shrimpton, Paul C. ;
Zankl, Maria ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :759-772
[8]   From patient-informed to patient-specific organ dose estimation in clinical computed tomography [J].
Fu, Wanyi ;
Segars, William P. ;
Abadi, Ehsan ;
Sharma, Shobhit ;
Kapadia, Anuj J. ;
Samei, Ehsan .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[9]  
Gupta S, 2015, INT J ENG TECHNOL MA, V3, P298
[10]   Cancer risks from diagnostic radiology: the impact of new epidemiological data [J].
Hall, E. J. ;
Brenner, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020) :E1316-E1317