Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

被引:26
|
作者
Dang, Jun [1 ]
Frisch, Benjamin [2 ]
Lasaygues, Philippe [3 ]
Zhang, Dachun [4 ]
Tavernier, Stefaan [1 ]
Felix, Nicolas
Lecoq, Paul [2 ]
Auffray, Etiennette [2 ]
Varela, Joao [5 ]
Mensah, Serge [3 ]
Wan, Mingxi [4 ]
机构
[1] Vrije Univ Brussel, B-1050 Brussels, Belgium
[2] CERN, CH-1211 Geneva 23, Switzerland
[3] Natl Ctr French Sci Res CNRS LMA, F-13402 Marseille 20, France
[4] Xi An Jiao Tong Univ, Xian 710049, Shaanxi, Peoples R China
[5] Lab Instrumentacao & Fis Expt Particulas LIP, P-1000149 Lisbon, Portugal
关键词
Breast; elastography; PET; ultrasound; MUTUAL-INFORMATION; REGISTRATION; OPTIMIZATION; MAXIMIZATION; MAMMOGRAPHY; SENSITIVITY;
D O I
10.1109/TNS.2011.2105279
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).
引用
收藏
页码:660 / 667
页数:8
相关论文
共 50 条
  • [31] Advanced Ultrasound Imaging in Glioma Surgery: Beyond Gray-Scale B-mode
    Del Bene, Massimiliano
    Perin, Alessandro
    Casali, Cecilia
    Legnani, Federico
    Saladino, Andrea
    Mattei, Luca
    Vetrano, Ignazio Gaspare
    Saini, Marco
    DiMeco, Francesco
    Prada, Francesco
    FRONTIERS IN ONCOLOGY, 2018, 8
  • [32] Correlates of mammographic density in B-mode ultrasound and real time elastography
    Jud, Sebastian Michael
    Haeberle, Lothar
    Fasching, Peter A.
    Heusinger, Katharina
    Hack, Carolin
    Faschingbauer, Florian
    Uder, Michael
    Wittenberg, Thomas
    Wagner, Florian
    Meier-Meitinger, Martina
    Schulz-Wendtland, Ruediger
    Beckmann, Matthias W.
    Adamietz, Boris R.
    EUROPEAN JOURNAL OF CANCER PREVENTION, 2012, 21 (04) : 343 - 349
  • [33] B-mode and Doppler ultrasound imaging of the spleen with canine splenic torsion: A retrospective evaluation
    Saunders, HM
    Neath, PJ
    Brockman, DJ
    VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (04) : 349 - 353
  • [34] Optimized differential diagnosis of breast lesions by combined B-mode and color Doppler sonography
    Schelling, M
    Gnirs, J
    Braun, M
    Busch, R
    Maurer, S
    Kuhn, W
    Schneider, KTM
    Graeff, H
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 10 (01) : 48 - 53
  • [35] AUTOMATED REGISTRATION OF FREEHAND B-MODE ULTRASOUND AND MAGNETIC RESONANCE IMAGING OF THE CAROTID ARTERIES BASED ON GEOMETRIC FEATURES
    Carvalho, Diego D. B.
    Lorza, Andres Mauricio Arias
    Niessen, Wiro J.
    De Bruijne, Marleen
    Klein, Stefan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01) : 273 - 285
  • [36] Breast Ultrasound Imaging Phantom to Mimic Malign Lesion Characteristics
    de Carvalho, I. M.
    Basto, R. L. Q.
    Infantosi, A. F. C.
    von Krueger, M. A.
    Pereira, W. C. A.
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 421 - 426
  • [37] Image quality and detection of pathology by ultrasound: Comparison of B-mode ultrasound with photopic imaging and tissue harmonic imaging alone and in combination
    Fischer, T
    Filimonow, S
    Taupitz, M
    Petersein, J
    Beyersdorff, D
    Bollow, M
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1313 - 1317
  • [38] Comparison of B-mode ultrasound, 3-dimensional ultrasound, and magnetic resonance imaging measurements of carotid atherosclerosis
    Egger, Micaela
    Krasinski, Adam
    Rutt, Brian K.
    Fenster, Aaron
    Parraga, Grace
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (09) : 1321 - 1334
  • [39] Added value of deep learning-based computer-aided diagnosis and shear wave elastography to b-mode ultrasound for evaluation of breast masses detected by screening ultrasound
    Kim, Min Young
    Kim, Soo-Yeon
    Kim, Yeon Soo
    Kim, Eun Sil
    Chang, Jung Min
    MEDICINE, 2021, 100 (31) : E26823
  • [40] Evaluation of focal lesions of the supraspinatus tendon with elastosonography: comparison with B-mode ultrasound and magnetic resonance imaging: our experience
    Francavilla, G.
    Sutera, R.
    Iovane, A.
    Candela, F.
    La Tona, G.
    Peritore, G.
    Sanfilippo, A.
    Francavilla, V. C.
    D'Arienzo, M.
    Midiri, M.
    MEDICINA DELLO SPORT, 2012, 65 (04) : 513 - 525