Determination of Three Estrogens in Environmental Water Samples Using Dispersive Liquid-Liquid Microextraction by High-Performance Liquid Chromatography and Fluorescence Detector

被引:20
|
作者
Sousa, Erika M. L. [1 ,2 ]
Dias, Reyla A. S. [3 ]
Sousa, Eliane R. [4 ]
Brito, Natilene M. [3 ]
Freitas, Arlan S. [3 ]
Silva, Gilberto S. [3 ]
Silva, Lanna K. [3 ]
Lima, Diana L. D. [1 ,2 ]
Esteves, Valdemar, I [1 ,2 ]
Silva, Gilmar S. [5 ]
机构
[1] Univ Aveiro, CESAM, Campus Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Chem, Campus Santiago, P-3810193 Aveiro, Portugal
[3] Fed Inst Educ Sci & Technol Maranhao, Dept Chem, Monte Castelo Campus,Genllio Vargas Ave 04, BR-65030005 Sao Luis, MA, Brazil
[4] Fed Inst Educ Sci & Technol Maranhao, Maracana Campus,Av Curios S-N, BR-65030005 Sao Luis, MA, Brazil
[5] Fed Inst Educ Sci & Technol Goias, Dept Chem, Monrinhos Campus,Highway BR 153,KM 633, BR-75650000 Morrinhos, Go, Brazil
关键词
Pharmaceuticals; Estrogens; High-performance liquid chromatography; Dispersive liquid-liquid microextraction; Water; SOLID-PHASE EXTRACTION; ENDOCRINE DISRUPTING CHEMICALS; RIO-DE-JANEIRO; IONIC LIQUID; SEASONAL DISTRIBUTION; WASTE-WATER; QUALITY; CONTAMINATION; ESTUARINE; EXPOSURE;
D O I
10.1007/s11270-020-04552-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work the dispersive liquid-liquid microextraction technique (DLLME) is presented as an important alternative to the classical extraction methods and was used to extract and concentrate estrogens' before its quantification by HPLC in environmental water samples. For the evaluation of the analytical methodology, the following conditions were used: sample volume 8 mL, extraction solvent 200 mu L of chlorobenzene, and dispersive solvent 2000 mu L of acetone. The enrichment factor (EF) was 140 for estrone, 202 for 17 beta-estradiol (E2), and 199 for 17 alpha-ethinylestradiol (EE2). Limit of detection was 20 ng L-1 for E1, 3.1 ng L-1 for E2, and 2.7 ng L-1 for EE2. Repeatability and intermediate reproducibility presented values of relative standard deviation lower than 10%. Finally, recovery tests were performed to evaluate the water matrices' effects on the extraction performance, resulting in recoveries between 76 and 110% in surface water and between 84 and 109% in wastewater.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Dispersive liquid-liquid microextraction combined with high performance liquid chromatography-DAD detection for the determination of sulfonylurea herbicides in water samples
    Wu, Qiu Hua
    Li, Yun Peng
    Li, Chao
    Wu, Chun Xia
    Liu, Zhi Mei
    Hou, Yu Xuan
    Wang, Zhi
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (11) : 891 - 902
  • [32] Dispersive liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of polynuclear aromatic hydrocarbons in environmental water samples
    Zhang Jianhua
    Huang Ying
    Chen Xiaoqiu
    Chen Jinhua
    Li Hui
    Chen Guonan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (06) : 799 - 803
  • [33] Simple, rapid, and sensitive determination of beta-blockers in environmental water using dispersive liquid-liquid microextraction followed by liquid chromatography with fluorescence detection
    Parrilla Vazquez, Ma del Mar
    Parrilla Vazquez, Piedad
    Martinez Galera, Maria
    Molina Sanchez, Luis
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (17) : 2184 - 2192
  • [34] Determination of Ochratoxin A in Pig Muscle Using Dispersive Liquid-liquid Microextraction Combined with High-Performance Liquid Chromatography
    Chuanlei Luan
    Lin Wang
    Fangfang Chen
    Shue Wang
    Li Zhao
    Lihua Shao
    Food Analytical Methods, 2016, 9 : 1490 - 1494
  • [35] Determination of triazines in honey by dispersive liquid-liquid microextraction high-performance liquid chromatography
    Wang, Ying
    You, Jingyan
    Ren, Ruibing
    Xiao, Yao
    Gao, Shiqian
    Zhang, Hanqi
    Yu, Aimin
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4241 - 4246
  • [36] Determination of Six Tetracyclines in Eggs and Chicken by Dispersive Liquid-Liquid Microextraction Combined with High-Performance Liquid Chromatography
    Yang, Yi
    Yin, Shuo
    Wu, Ling
    Li, Yongxin
    Sun, Chengjun
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (06) : 1549 - 1558
  • [37] DETERMINATION OF TETRACYCLINES IN WATER BY ETHYL ACETATE-IONIC LIQUID DISPERSIVE LIQUID-LIQUID MICROEXTRACTION AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Du, Dongli
    Wu, Yuanyuan
    Kang, Duan
    Wang, Huili
    Huang, Changjiang
    Li, Yanyan
    ANALYTICAL LETTERS, 2014, 47 (10) : 1783 - 1795
  • [38] Magnetic stirring-assisted dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalate esters in drinking and environmental water samples
    Ranjbari, Elias
    Hadjmohammadi, Mohammad Reza
    TALANTA, 2012, 100 : 447 - 453
  • [39] Ionic-liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography for the determination of multiclass pesticide residues in water samples
    Tadesse, Bezuayehu
    Teju, Endale
    Gure, Abera
    Megersa, Negussie
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (05) : 829 - 835
  • [40] Dispersive liquid-liquid microextraction coupled with single-drop microextraction for the fast determination of sulfonamides in environmental water samples by high performance liquid chromatography-ultraviolet detection
    Li, Xiaoyi
    Li, Quanle
    Xue, Aifang
    Chen, Hao
    Li, Shengqing
    ANALYTICAL METHODS, 2016, 8 (03) : 517 - 525