Determination of Three Estrogens in Environmental Water Samples Using Dispersive Liquid-Liquid Microextraction by High-Performance Liquid Chromatography and Fluorescence Detector

被引:20
|
作者
Sousa, Erika M. L. [1 ,2 ]
Dias, Reyla A. S. [3 ]
Sousa, Eliane R. [4 ]
Brito, Natilene M. [3 ]
Freitas, Arlan S. [3 ]
Silva, Gilberto S. [3 ]
Silva, Lanna K. [3 ]
Lima, Diana L. D. [1 ,2 ]
Esteves, Valdemar, I [1 ,2 ]
Silva, Gilmar S. [5 ]
机构
[1] Univ Aveiro, CESAM, Campus Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Chem, Campus Santiago, P-3810193 Aveiro, Portugal
[3] Fed Inst Educ Sci & Technol Maranhao, Dept Chem, Monte Castelo Campus,Genllio Vargas Ave 04, BR-65030005 Sao Luis, MA, Brazil
[4] Fed Inst Educ Sci & Technol Maranhao, Maracana Campus,Av Curios S-N, BR-65030005 Sao Luis, MA, Brazil
[5] Fed Inst Educ Sci & Technol Goias, Dept Chem, Monrinhos Campus,Highway BR 153,KM 633, BR-75650000 Morrinhos, Go, Brazil
关键词
Pharmaceuticals; Estrogens; High-performance liquid chromatography; Dispersive liquid-liquid microextraction; Water; SOLID-PHASE EXTRACTION; ENDOCRINE DISRUPTING CHEMICALS; RIO-DE-JANEIRO; IONIC LIQUID; SEASONAL DISTRIBUTION; WASTE-WATER; QUALITY; CONTAMINATION; ESTUARINE; EXPOSURE;
D O I
10.1007/s11270-020-04552-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work the dispersive liquid-liquid microextraction technique (DLLME) is presented as an important alternative to the classical extraction methods and was used to extract and concentrate estrogens' before its quantification by HPLC in environmental water samples. For the evaluation of the analytical methodology, the following conditions were used: sample volume 8 mL, extraction solvent 200 mu L of chlorobenzene, and dispersive solvent 2000 mu L of acetone. The enrichment factor (EF) was 140 for estrone, 202 for 17 beta-estradiol (E2), and 199 for 17 alpha-ethinylestradiol (EE2). Limit of detection was 20 ng L-1 for E1, 3.1 ng L-1 for E2, and 2.7 ng L-1 for EE2. Repeatability and intermediate reproducibility presented values of relative standard deviation lower than 10%. Finally, recovery tests were performed to evaluate the water matrices' effects on the extraction performance, resulting in recoveries between 76 and 110% in surface water and between 84 and 109% in wastewater.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Determination of Three Estrogens in Environmental Water Samples Using Dispersive Liquid-Liquid Microextraction by High-Performance Liquid Chromatography and Fluorescence Detector
    Érika M. L. Sousa
    Reyla A. S. Dias
    Eliane R. Sousa
    Natilene M. Brito
    Arlan S. Freitas
    Gilberto S. Silva
    Lanna K. Silva
    Diana L. D Lima
    Valdemar I. Esteves
    Gilmar S. Silva
    Water, Air, & Soil Pollution, 2020, 231
  • [2] Determination of Estrogens in Water Samples Using Dispersive Liquid Liquid Microextraction and High Performance Liquid Chromatography
    Hadjmohammadi, Mohammad Reza
    Ghoreishi, Seyedeh Saboora
    ACTA CHIMICA SLOVENICA, 2011, 58 (04) : 765 - 771
  • [3] Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection
    Zhang, Rui
    Wang, Chuanliu
    Yue, Qiaohong
    Zhou, Tiecheng
    Li, Na
    Zhang, Hanqi
    Hao, Xiaoke
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (21) : 3133 - 3141
  • [4] DETERMINATION OF ESTROGENS IN WATER SAMPLES BY IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Wu, Cui-Qin
    Chen, Di-Yun
    Feng, Yin-Si
    Deng, Hong-Mei
    Liu, Yong-Hui
    Zhou, Ai-Ju
    ANALYTICAL LETTERS, 2012, 45 (14) : 1995 - 2005
  • [5] Application of dispersive liquid-liquid microextraction and high-performance liquid chromatography for the determination of three phthalate esters in water samples
    Liang, Pei
    Xu, Jing
    Li, Qian
    ANALYTICA CHIMICA ACTA, 2008, 609 (01) : 53 - 58
  • [6] Speciation analysis of mercury in water samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography
    Gao, Zhongben
    Ma, Xiaoguo
    ANALYTICA CHIMICA ACTA, 2011, 702 (01) : 50 - 55
  • [7] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of three carbamate pesticides in water samples
    He, Lijun
    Wang, Chunjian
    Sun, Yinjuan
    Luo, Xianli
    Zhang, Jing
    Lu, Kui
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (06) : 439 - 448
  • [8] Determination of fluoroquinolones in the environmental samples using vortex assisted dispersive liquid-liquid microextraction coupled with high performance liquid chromatography
    Selahle, Shirley Kholofelo
    Nomngongo, Philiswa N.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (03) : 282 - 294
  • [9] Application of dispersive liquid-liquid microextraction combined with high-performance liquid chromatography to the determination of carbamate pesticides in water samples
    Wu, Qiuhua
    Zhou, Xin
    Li, Yuemin
    Zang, Xiaohuan
    Wang, Chun
    Wang, Zhi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (6-7) : 1755 - 1761
  • [10] Determination of polybrominated biphenyls in environmental water samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography
    Wang, Xuemei
    Du, Tongtong
    Wang, Juan
    Kou, Haixia
    Du, Xinzhen
    MICROCHEMICAL JOURNAL, 2019, 148 : 85 - 91