Analysis and Control of Modular Multilevel Matrix Converters Under Branch Fault Conditions
被引:12
|
作者:
Wang, Chao
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R ChinaTsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
Wang, Chao
[1
]
Zheng, Zedong
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R ChinaTsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
Zheng, Zedong
[1
]
Wang, Kui
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R ChinaTsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
Wang, Kui
[1
]
Yang, Bo
论文数: 0引用数: 0
h-index: 0
机构:
Xian Univ Technol, Dept Elect Engn, Xian 710048, Peoples R ChinaTsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
Yang, Bo
[2
]
Zhou, Peiyi
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R ChinaTsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
Zhou, Peiyi
[1
]
Li, Yongdong Gae
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R ChinaTsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
Li, Yongdong Gae
[1
]
机构:
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] Xian Univ Technol, Dept Elect Engn, Xian 710048, Peoples R China
The modular multilevel matrix converter (M3C) is a promising topology for high-voltage and high-power direct ac-to-ac power conversion applications. Fault tolerance ability is one of the advantages of the M3C. To further enhance the reliability of the M3C, this article proposes a novel branch current configuration method for branch fault conditions, which is available either one or two branches are failed. By deriving basic branch current configurations and analyzing branch dc power equations under branch fault conditions, feasible branch current configurations can be directly derived. In terms of minimizing the maximum peak branch current, the derived configuration is also the optimal one for the single branch fault condition. Compared with the existing method, the proposed method does not need to solve configuration coefficients of branch currents offline, which is automatically adaptive to different load conditions. An M3C prototype with three submodules each branch is built, and experimental results are presented to validate the proposed branch fault tolerance method.