Comparison of diffusion tensor imaging by cardiovascular magnetic resonance and gadolinium enhanced 3D image intensity approaches to investigation of structural anisotropy in explanted rat hearts

被引:34
作者
Bernus, Olivier [1 ]
Radjenovic, Aleksandra [2 ]
Trew, Mark L. [3 ]
LeGrice, Ian J. [3 ,4 ]
Sands, Gregory B. [3 ]
Magee, Derek R. [5 ]
Smaill, Bruce H. [3 ,4 ]
Gilbert, Stephen H. [6 ]
机构
[1] Univ Bordeaux, Inst Rythmol & Modelisat Cardiaque LIRYC, Inserm U1045, Ctr Rech Cardiothorac, F-33604 Pessac, France
[2] Univ Glasgow, BHF Glasgow, Cardiovasc Res Ctr, Inst Cardiovasc & Med Sci, Glasgow G12 8TA, Lanark, Scotland
[3] Univ Auckland, Auckland Bioengn Inst, Auckland 1, New Zealand
[4] Univ Auckland, Dept Physiol, Auckland, New Zealand
[5] Univ Leeds, Sch Comp, Leeds LS2 9JT, W Yorkshire, England
[6] Max Delbruck Ctr Mol Med MDC, Math Cell Physiol, D-13125 Berlin, Germany
基金
英国医学研究理事会;
关键词
Diffusion tensor imaging; Cardiovascular magnetic resonance; Myocardium; Myolaminar; CARDIAC FIBER; HISTOLOGICAL VALIDATION; VENTRICULAR MYOCARDIUM; LAMINAR STRUCTURE; SHEET STRUCTURE; CONFOCAL MICROSCOPY; WATER DIFFUSION; MRI; TISSUE; QUANTIFICATION;
D O I
10.1186/s12968-015-0129-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) can through the two methods 3D FLASH and diffusion tensor imaging (DTI) give complementary information on the local orientations of cardiomyocytes and their laminar arrays. Methods: Eight explanted rat hearts were perfused with Gd-DTPA contrast agent and fixative and imaged in a 9.4T magnet by two types of acquisition: 3D fast low angle shot (FLASH) imaging, voxels 50 x 50 x 50 mu m, and 3D spin echo DTI with monopolar diffusion gradients of 3.6 ms duration at 11.5 ms separation, voxels 200 x 200 x 200 mu m. The sensitivity of each approach to imaging parameters was explored. Results: The FLASH data showed laminar alignments of voxels with high signal, in keeping with the presumed predominance of contrast in the interstices between sheetlets. It was analysed, using structure-tensor (ST) analysis, to determine the most (v(1)(ST)), intermediate (v(2)(ST)) and least (v(3)(ST)) extended orthogonal directions of signal continuity. The DTI data was analysed to determine the most (e(1)(DTI)), intermediate (e(2)(DTI)) and least (e(3)(DTI)) orthogonal eigenvectors of extent of diffusion. The correspondence between the FLASH and DTI methods was measured and appraised. The most extended direction of FLASH signal (v(1)(ST)) agreed well with that of diffusion (e(1)(DTI)) throughout the left ventricle (representative discrepancy in the septum of 13.3 +/- 6.7 degrees: median +/- absolute deviation) and both were in keeping with the expected local orientations of the long-axis of cardiomyocytes. However, the orientation of the least directions of FLASH signal continuity (v(3)(ST)) and diffusion (e(3)(ST)) showed greater discrepancies of up to 27.9 +/- 17.4 degrees. Both FLASH (v(3)(ST)) and DTI (e(3)(DTI)) where compared to directly measured laminar arrays in the FLASH images. For FLASH the discrepancy between the structure-tensor calculated v(3)(ST) and the directly measured FLASH laminar array normal was of 9 +/- 7 degrees for the lateral wall and 7 +/- 9 degrees for the septum (median +/- inter quartile range), and for DTI the discrepancy between the calculated v(3)(DTI) and the directly measured FLASH laminar array normal was 22 +/- 14 degrees and 61 +/- 53.4 degrees. DTI was relatively insensitive to the number of diffusion directions and to time up to 72 hours post fixation, but was moderately affected by b-value (which was scaled by modifying diffusion gradient pulse strength with fixed gradient pulse separation). Optimal DTI parameters were b = 1000 mm/s(2) and 12 diffusion directions. FLASH acquisitions were relatively insensitive to the image processing parameters explored. Conclusions: We show that ST analysis of FLASH is a useful and accurate tool in the measurement of cardiac microstructure. While both FLASH and the DTI approaches appear promising for mapping of the alignments of myocytes throughout myocardium, marked discrepancies between the cross myocyte anisotropies deduced from each method call for consideration of their respective limitations.
引用
收藏
页数:27
相关论文
共 65 条
  • [31] Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation
    Hsu, EW
    Muzikant, AL
    Matulevicius, SA
    Penland, RC
    Henriquez, CS
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (05): : H1627 - H1634
  • [32] Delayed reduction of tissue water diffusion after myocardial ischemia
    Hsu, EW
    Xue, R
    Holmes, A
    Forder, JR
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 275 (02): : H697 - H702
  • [33] Myocardial fiber orientation mapping using reduced encoding diffusion tensor imaging
    Hsu, EW
    Henriquez, CS
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (04) : 339 - 347
  • [34] Two-component diffusion tenser MRI of isolated perfused hearts
    Hsu, EW
    Buckley, DL
    Bui, JD
    Blackband, SJ
    Forder, JR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) : 1039 - 1045
  • [35] Hsu EW, 2002, JOINT EMBS BMES C OC, P1169
  • [36] Jahne B., 2005, DIGITAL IMAGE PROCES
  • [37] Three-dimensional diffusion tensor microscopy of fixed mouse hearts
    Jiang, Y
    Pandya, K
    Smithies, O
    Hsu, EW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 453 - 460
  • [38] Dependence on diffusion time of apparent diffusion tensor of ex vivo calf tongue and heart
    Kim, S
    Chi-Fishman, G
    Barnett, AS
    Pierpaoli, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1387 - 1396
  • [39] Selection of the optimum b factor for diffusion-weighted magnetic resonance imaging assessment of ischemic stroke
    Kingsley, PB
    Monahan, WG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 996 - 1001
  • [40] Visualization of myocardial microstructure using high-resolution T2* imaging at high magnetic field
    Köhler, S
    Hiller, KH
    Waller, C
    Jakob, PM
    Bauer, WR
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 371 - 375